MRT-2450G-R(450W)
製品種別 | 電源 (Zippy) |
---|---|
電源の種類 | Mini Redundant |
製品説明 |
製品仕様
wattage | 450W |
---|---|
solution | Server ,Workstation ,Storage System ,IPC |
dimension_mm | 163x120x41.4 |
dimension_inch | 6.42x4.72x1.63 |
input_spec | VOLTAGE: 90 ~ 264 VAC FULL RANGE FREQUENCY : 47 ~ 63 Hz INPUT CURRENT: 7A/3A @ 115/230 VAC INRUSH CURRENT: 25/50 AMPS @115/230 VAC (AT 25 DEGREES AMBIENT COLD START FOR EACH POWER UNIT) POWER FACTOR CORRECTION: PFC CAN REACH THE TARGET OF 95%@115V AND 90%@230V, FULL LOAD, FOLLOWING THE STANDARD OF IEC61000-3-2 CLASS D |
dc_output |
|
features | * TEMPERATURE RANGE : OPERATING 0℃ ~ 50℃, STORAGE –20℃ ~ 80℃ * HOLD UP TIME: 16 ms MINIMUM AT FULL LOAD & 90 VAC INPUT VOLTAGE * EFFICIENCY: THE MAXIMUM POWER SUPPLY SYSTEM EFFICIENCY SHALL BE 87.8%, MEASURED AT NOMINAL INPUT VOLTAGE 230V AND FULL LOADING. * OUTPUT PROTECTION: OPP / OVP / OCP / SCP * REMOTE ON/OFF CONTROL * LEAKAGE CURRENT: 3.5mA. RMS. MEASUREMENT WILL BE MADE AT 240VAC AND 60HZ * THE POWER-SUPPLY IS FOR CHASSIS-ASSEMBLY ONLY AND IS NOT ALLOWED TO BE OPERATED AS STAND-ALONE COMPONENT. FINAL ASSEMBLY HAS TO COMPLY WITH CORRESPONDING EMC- AND SAFETY-REGULATIONS. |
CB:http://www.zippy.com.tw//backend/DownLoad/DownLoad/Power/CB/MRT-G%20&%20MRT-5XXXG0V%20CB.pdf TUV:http://www.zippy.com.tw//backend/DownLoad/DownLoad/Power/TUV/MRT-G%20TUVpdf.pdf MTBF(RoHS):http://www.zippy.com.tw//backend/DownLoad/DownLoad/Power/MTBF/MRT-2450G-R(RoHS).pdf DRAWING:http://www.zippy.com.tw//backend/DownLoad/DownLoad/Power/DRAWING/MRTGRMA01.pdf |