製品情報

M1U2-5750V4H(750W)

製品種別 電源 (Zippy)
電源の種類 Micro Redundant
製品説明

製品仕様

wattage 750W
solution Server ,Workstation ,Storage System
dimension_mm 355x106x41.8
dimension_inch 13.98x4.17x1.65
input_spec VOLTAGE: 90~264VAC FULL RANGE FREQUENCY: 47~63HZ INPUT CURRENT:6A(RMS)FOR 230VAC 12A(RMS)FOR 115VAC INRUSH CURRENT:15A MAX. FOR 115 VAC PER MODULE 30A MAX. FOR 230 VAC PER MODULE
dc_output Output VoltageOutput Current Min.Output Current Max.Regulation LoadRegulation LineOutput Ripple & Noise Max.[P-P]+5V022±5%±1%50mV+12V262±5%±1% 120mV -12V00.5±5%±1%120mV+3.3V022±5%±1%50mV+5VSB0.13±5%±1%50mV
* POWER MODULE TOTAL OUTPUT POWER OF +5V AMD +3.3V NOT EXCEED 150W

features * TEMPERATURE RANGE:OPERATING 0℃~50℃,STORAGE -20℃~80℃
* HOLD UP TIME:11mS MIN. AT FULL LOAD & 115 VAC INPUT VOLTAGE
* DIELECTRIC WITHSTAND:INPUT/OUTPUT 1500 VAC FOR 1 MINUTE
* INPUT TO FRAME GROUND 1500 VAC FOR 1 minute
* EFFICIENCY:TYPICAL 85% AT 115V, 12V/54A 5VSB/0.4A; TYPICAL 88% AT 230V, 12V/54A 5VSB/0.4A
* POWER GOOD SIGNAL:ON DELAY 100mS TO 500mS,OFF DELAY 1mS
* OVER POWER PROTECTION:110~150% MAX
* OVER VOLTAGE PROTECTION:+3.3V→3.7~4.1V, +5V→5.7~6.5V, +12V→12.8~13.9V
* SHORT CIRCUIT PROTECTION: +5V, +3.3V, +12V, -12V
* SAFETY:TO MEET UL, CUL, TUV
* FAULTY ALARM METHODS: LED, BUZZER, TTL SIGNAL
* MEET IEC-1000-3-2 CLASS D (ACTIVE PFC)


*THE POWER-SUPPLY IS FOR CHASSIS-ASSEMBLY ONLY AND IS NOT ALLOWED TO BE OPERATED AS STAND-ALONE COMPONENT. FINAL ASSEMBLY HAS TO COMPLY WITH CORRESPONDING EMC- AND SAFETY-REGULATIONS.
pdf TUV:http://www.zippy.com.tw//backend/DownLoad/DownLoad/Power/TUV/M1U-V%20&%20M1U2-V%20TUV.pdf CB:http://www.zippy.com.tw//backend/DownLoad/DownLoad/Power/CB/M1U-V%20&%20M1U2-V%20&%20M1V-V%20&%20M1V2-V%20CB.pdf CCC:http://www.zippy.com.tw//backend/DownLoad/DownLoad/Power/CCC/M1U-V%20&%20M1U2-V%20CCC.pdf MTBF(RoHS):http://www.zippy.com.tw//backend/DownLoad/DownLoad/Power/MTBF/M1U2-5750V4H(RoHS).pdf MTBF(RoHS)(35℃):http://www.zippy.com.tw//backend/DownLoad/DownLoad/Power/MTBF/M1U2-5750V4H(RoHS)(35%e2%84%83).pdf DRAWING:http://www.zippy.com.tw//backend/DownLoad/DownLoad/Power/DRAWING/M1U2MA10.pdf CE(Radiation):http://www.zippy.com.tw//backend/DownLoad/DownLoad/Power/CE/M1U2-5750V4H%20(Radiation).pdf BSMI:http://www.zippy.com.tw//backend/DownLoad/DownLoad/Power/BSMI/M1U-V%20&%20M1V-V%20&%20M1U2-V%20&%20M1V2-V%20BSMI.pdf MTBF(RoHS)(40℃):http://www.zippy.com.tw//backend/DownLoad/DownLoad/Power/MTBF/M1U2-5750V4H(RoHS)(30%e2%84%83).pdf