製品情報

M1K2-5C01V4H(1200W)

製品種別 電源 (Zippy)
電源の種類 Micro Redundant
製品説明

製品仕様

wattage 1200W
solution Server ,Workstation ,Storage System
dimension_mm 400x106x41.3
dimension_inch 15.75x4.17x1.63
input_spec VOLTAGE: 90~264VAC FULL RANGE FREQUENCY: 47~63HZ INPUT CURRENT:7.5A (RMS)FOR 230VAC 15A(RMS)FOR 115VAC INRUSH CURRENT:15A MAX. FOR 115 VAC PER MODULE 30A MAX. FOR 230 VAC PER MODULE
dc_output Output VoltageOutput Current Min.Output Current Max.Regulation LoadRegulation LineOutput Ripple & Noise Max.[P-P]+5V036±5%±1%50mV+12V2100±5%±1% 120mV -12V00.5±5%±1%120mV+3.3V031±5%±1%50mV+5VSB0.13±5%±1%50mV
* POWER MODULE TOTAL OUTPUT POWER OF +5V AND +3.3V NOT EXCEED 210W
* POWER MODULE TOTAL OUTPUT POWER NOT EXCEED 1200W


features * TEMPERATURE RANGE:OPERATING 0℃~50℃,STORAGE -20℃~80℃
* HOLD UP TIME:10mS MIN. AT FULL LOAD & 115 VAC INPUT VOLTAGE
* DIELECTRIC WITHSTAND:INPUT/OUTPUT 1500 VAC FOR 1 minute INPUT TO FRAME GROUND 1500 VAC FOR 1 minute
* EFFICIENCY:TYPICAL 83% AT 115V, 12V/83A 5VSB/0.1A; TYPICAL 86% AT 230V, 12V/83A 5VSB/0.1A
* POWER GOOD SIGNAL:ON DELAY 100mS TO 500mS,OFF DELAY 1mS
* OVER POWER PROTECTION:110~150% MAX
* OVER VOLTAGE PROTECTION:+3.3V→3.7~4.1V, +5V→5.7~6.5V, +12V→12.8~13.9V
* SHORT CIRCUIT PROTECTION: +5V, +3.3V, +12V, -12V
* SAFETY:TO MEET UL, CUL, TUV
* FAULTY ALARM METHODS: LED, BUZZER, TTL SIGNAL
* MEET IEC-1000-3-2 CLASS D (ACTIVE PFC)


* THE POWER-SUPPLY IS FOR CHASSIS-ASSEMBLY ONLY AND IS NOT ALLOWED TO BE OPERATED AS STAND-ALONE COMPONENT. FINAL ASSEMBLY HAS TO COMPLY WITH CORRESPONDING EMC- AND SAFETY-REGULATIONS.
pdf DRAWING:http://www.zippy.com.tw//backend/DownLoad/DownLoad/Power/DRAWING/M1K2MA01.pdf CB:http://www.zippy.com.tw//backend/DownLoad/DownLoad/Power/CB/M1K-V%20and%20M1K2-V%20CB.pdf TUV:http://www.zippy.com.tw//backend/DownLoad/DownLoad/Power/TUV/M1K-V%20and%20M1K2-V%20TUV.pdf CCC:http://www.zippy.com.tw//backend/DownLoad/DownLoad/Power/CCC/M1K-V%20and%20M1K2-V%20CCC.pdf MTBF(RoHS)(35℃):http://www.zippy.com.tw//backend/DownLoad/DownLoad/Power/MTBF/M1K2-5C01V4H(RoHS)(35%e2%84%83).pdf MTBF(RoHS):http://www.zippy.com.tw//backend/DownLoad/DownLoad/Power/MTBF/M1K2-5C01V4H(RoHS).pdf CE (Radiation):http://www.zippy.com.tw//backend/DownLoad/DownLoad/Power/CE/M1K2-5C01V4H%20(Radiation).pdf FCC:http://www.zippy.com.tw//backend/DownLoad/DownLoad/Power/FCC/M1K2-5C01V4H%20FCC.pdf MTBF(RoHS)(40℃):http://www.zippy.com.tw//backend/DownLoad/DownLoad/Power/MTBF/M1K2-5C01V4H(RoHS)(40%e2%84%83).pdf