DM1R2-5500V0H(500W)
製品種別 | 電源 (Zippy) |
---|---|
電源の種類 | Micro Redundant DC |
製品説明 |
製品仕様
wattage | 500W |
---|---|
solution | Server ,Workstation ,Storage System |
dimension_mm | 295x106x41.3 |
dimension_inch | 11.61x4.17x1.63 |
input_spec | VOLTAGE:-36 ~ -72 VDC STEADY-STATE CURRENT: 10A MAX @ -48VDC INRUSH CURRENT: 10A MAX. @-48VDC INPUT (AT 25DEGREES AMBIENT COLD START FOR EACH POWER UNIT) STEADY-STATE CURRENT: 20/10 AMPS maximum at any low/high range input voltage START UP CURRENT: 30 AMPS MAX.@ -48VDC INPUT (AT 25 DEGREES AMBIENT COLD START) |
dc_output |
|
features | * TEMPERATURE RANGE:OPERATING 0℃~50℃, STOREAGE -20℃~80℃ * HOLD UP TIME:1mS IN REGULATOIN LIMIT AT NORMAL INPUT VOLTAGE (DC -48V) * EFFICIENCY(PER SET):The maximum power supply system efficiency shall be 85%, measured at nominal input voltage -48Vdc and 50% loading * OUTPUT PROTECTION: OPP/OVP/SCP * REMOTE ON/OFF CONTROL * BALANCE LOAD SHARING DESIGN * * FAULTY ALARM METHODS: BUZZER, TTL SIGNAL * EMI: FCC, CISPR 22(EN 55022) * EMS: EN 61000-4-2 ESD, EN61000-4-4 EFT, EN61000-4-5 SURGE * SAFETY APPROVAL: UL, CUL, TUV, CCC * THE POWER-SUPPLY IS FOR CHASSIS-ASSEMBLY ONLY AND IS NOT ALLOWED TO BE OPERATED AS STAND-ALONE COMPONENT. FINAL ASSEMBLY HAS TO COMPLY WITH CORRESPONDING EMC- AND SAFETY-REGULATIONS. |
DRAWING:http://www.zippy.com.tw//backend/DownLoad/DownLoad/Power/DRAWING/DM1R2VMA00.pdf CCC:http://www.zippy.com.tw//backend/DownLoad/DownLoad/Power/CCC/DM1R2-V%20CCC.pdf |