製品情報

P3M-9950P(950W)

製品種別 電源 (Zippy)
電源の種類 3U Single
製品説明

製品仕様

wattage 950W
solution Server ,Workstation ,Storage System ,IPC ,Communication
dimension_mm 300x100x127
dimension_inch 11.81x3.93x5
input_spec VOLTAGE: 100V ~ 240VAC (WITH ± 10% TOLERANCE) FREQUENCY: 47Hz ~ 63Hz INPUT CURRENT: 10A/5A AY ANY LOW/HIGH RANGE INPUT VOLTAGE INRUSH CURRENT: 140/160A @ 110/220VAC (25℃) POWER FACTOR CORRECTION: 95% @ 230V, FULL LOAD
dc_output Output VoltageOutput Current Min.Output Current Max.Regulation LoadRegulation LineOutput Ripple & Noise Max.[P-P]+5V13.025± 5%± 50mV80mV+5V22.535± 5%± 50mV 80mV +12V12.028± 5%± 50mV120mV+12V22.042± 5%± 50mV120mV-5V00.8± 5%± 50mV100mV-12V01.0± 5%± 50mV100mV+3.3V1020± 5%± 50mV80mV+3.3V21.030± 5%± 50mV80mV+5VSB0.12± 5%± 50mV80mV


features ‧TEMPERATURE RANGE: OPERATING: 0℃ --- 40℃ STORAGE: -20℃ --- 80℃
‧HUMIDITY:OPERATING:20%-95%, NON-OPERATING:10%-95%
‧REMARKS:85% IS NORMAL CONDITION AND 95% IS WITH SPECIAL COATING PROCESS
‧HOLD UP TIME: 16 ms MINIMUM AT FULL LOAD & NORMAL INPUT VOLTAGE
‧DIELECTRIC WITHSTAND: INPUT / OUTPUT 1800 VAC FOR 1 SECOND
INPUT TO FRAME GROUND 1800 VAC FOR 1 SECOND
‧ EFFICIENCY: 70% TYPICAL AT 115VAC FULL LOAD
‧POWER GOOD SIGNAL: ON DELAY 100 ms TO 500 ms, OFF DELAY 1 ms
‧OVER POWER PROTECTION: 110% ~ 150%
‧OVEROVER VOLTAGE PROTECTION: If an over voltage fault occurs,the power supply will latch all DC output into a shutdown state.

Min

Typical

Max

+3.3V1

3.7V

4.1V

4.3V

+3.3V2

3.7V

4.1V

4.3V

+5V1

5.7V

6.1V

6.5V

+5V2

5.7V

6.1V

6.5V

+12V1

13.6V

14.3V

15V

+12V2

13.6V

14.3V

15V

OVER CURRENT PROTECTION: If an over current fault occurs,the power supply will latch all DC output into a shutdown state.

Min

Typical

Max

+3.3V2

33A

39A

45A

+5V2

38.5A

45.5A

52.5A

+12V2

46.2A

54.6A

63A

‧SHORT CIRCUIT PROTECTION: +5V1,+5V2, -5V, +12V1,+12V2, -12V, +3.3V1,+3.3V2
‧EMI NOISE FILTER: FCC CLASS B CISPR22 CLASS B
‧REMOTE ON / OFF CONTROL
THE UNIT SHALL ACCEPT A LOGIC OPEN COLLECTOR LEVEL WHICH WILL DISABLE / ENABLE ALL THE OUTPUT VOLTAGE (EXCLUDE +5V STANDBY),
AS LOGIC LEVEL IS LOW, OUTPUTS VOLTAGE WERE ENABLE,
AS LOGIC LEVEL IS HIGH, OUTPUTS VOLTAGE WERE DISABL


*THE POWER-SUPPLY IS FOR CHASSIS-ASSEMBLY ONLY AND IS NOT ALLOWED TO BE OPERATED AS STAND-ALONE COMPONENT. FINAL ASSEMBLY HAS TO COMPLY WITH CORRESPONDING EMC- AND SAFETY-REGULATIONS.
pdf MTBF:http://www.zippy.com.tw//backend/DownLoad/DownLoad/Power/MTBF/P3M-9950P.pdf DRAWING:http://www.zippy.com.tw//backend/DownLoad/DownLoad/Power/DRAWING/P3M0MA03.pdf FCC:http://www.zippy.com.tw//backend/DownLoad/DownLoad/Power/FCC/P3M-9550P%20FCC.pdf CE:http://www.zippy.com.tw//backend/DownLoad/DownLoad/Power/CE/P3M-9950P.pdf