DR2G-6350F(350W)
製品種別 | 電源 (Zippy) |
---|---|
電源の種類 | 2U Redundant DC |
製品説明 |
製品仕様
wattage | 350W |
---|---|
solution | Server ,Workstation ,Storage System ,IPC ,Communication ,Networking |
dimension_mm | 300x101x82 |
dimension_inch | 118.11x39.76x32.28 |
input_spec | VOLTAGE: DC -36 V~ -72 V INPUT CURRENT: 35A TYPICAL INRUSH CURRENT: LESS THAN 10A FOR EACH MODULE |
dc_output |
|
features | * TEMPERATURE RANGE: OPERATING: -10℃ --- 40℃(-36V ~-72VDC INPUT) -10℃ --- 50℃(-46V~-72VDC INPUT) STORAGE: -20℃ --- 80℃ * HUMIDITY:OPERATING:20%-95%, NON-OPERATING:10%-95% * REMARKS:85% IS NORMAL CONDITION AND 95% IS WITH SPECIAL COATING PROCESS * HOLD UP TIME: 1.6 ms MINIMUM AT FULL LOAD & NORMAL INPUT VOLTAGE * DIELECTRIC WITHSTAND: INPUT / OUTPUT 1500 VAC FOR 1 SECOND INPUT TO FRAME GROUND 1500 VAC FOR 1 SECOND * EFFICIENCY: 65% TYPICAL AT -48VDC FULL LOAD * POWER GOOD SIGNAL: ON DELAY 100 ms TO 500 ms, OFF DELAY 1 ms * OVER POWER PROTECTION: 110% ~ 160% OVER VOLTAGE PROTECTION: +5V → 5.7V ~ 6.7V, 3.3V → 3.7V ~ 4.7V +12V → 13.0V ~ 15.0V OVER CURRENT PROTECTION: 110% ~ 150% * SHORT CIRCUIT PROTECTION: +5V, -5V, +12V, -12V, +3.3V, +5VSB * EMI NOISE FILTER: FCC CLASS A, CISPR22 CLASS A * SAFETY: UL 1950, CSA 22.2 NO/ 950, TÜV IEC 950 * REMOTE ON / OFF CONTROL THE UNIT SHALL ACCEPT A LOGIC OPEN COLLECTOR LEVEL WHICH WILL DISABLE / ENABLE ALL THE OUTPUT VOLTAGE (EXCLUDE +5V STANDBY), AS LOGIC LEVEL IS LOW, OUTPUTS VOLTAGE WERE ENABLE, AS LOGIC LEVEL IS HIGH, OUTPUTS VOLTAGE WERE DISABLE. * 3.3V / 5V REMOTE SENSING * CONNECTOR POWER INPUT A. POSITRONIC: PLB06M CONNECTOR B. TERMINAL BLOCK *THE POWER-SUPPLY IS FOR CHASSIS-ASSEMBLY ONLY AND IS NOT ALLOWED TO BE OPERATED AS STAND-ALONE COMPONENT. FINAL ASSEMBLY HAS TO COMPLY WITH CORRESPONDING EMC- AND SAFETY-REGULATIONS. |
CB:http://www.zippy.com.tw//backend/DownLoad/DownLoad/Power/CB/DR2G,DR3G,DGIHX%20CB.pdf TUV:http://www.zippy.com.tw//backend/DownLoad/DownLoad/Power/TUV/DR2G,DR3G,DGIHX%20TUV.pdf MTBF:http://www.zippy.com.tw//backend/DownLoad/DownLoad/Power/MTBF/DR2G-6350F.pdf DRAWING:http://www.zippy.com.tw//backend/DownLoad/DownLoad/Power/DRAWING/DR2GMA00.pdf MANUAL:http://www.zippy.com.tw//backend/DownLoad/DownLoad/Power/MANUAL/DR2G%20%20DR3G%20Series.pdf CCC:http://www.zippy.com.tw//backend/DownLoad/DownLoad/Power/CCC/DR2G,DR3G%20CCC.pdf MTBF(RoHS):http://www.zippy.com.tw//backend/DownLoad/DownLoad/Power/MTBF/DR2G-6350F(RoHS).pdf CE:http://www.zippy.com.tw//backend/DownLoad/DownLoad/Power/CE/DR2G-6350F.pdf FCC:http://www.zippy.com.tw//backend/DownLoad/DownLoad/Power/FCC/DR2G-6350F%20FCC.pdf |