M1L2-5650P3V(650W)
製品種別 | 電源 (Zippy) |
---|---|
電源の種類 | 2U Redundant |
製品説明 |
製品仕様
wattage | 650W |
---|---|
solution | Server ,Workstation ,Storage System ,IPC |
dimension_mm | 330x101.2x84 |
dimension_inch | 12.9x3.98x3.31 |
input_spec | VOLTAGE: 90~264VAC FULL RANGE FREQUENCY: 47~63HZ INPUT CURRENT: 5A (RMS) FOR 230VAC 10A (RMS) FOR 115VAC INRUSH CURRENT: 40A MAX.FOR 115 VAC PER MODULE 60A MAX. FOR 230 VAC PER MODULE |
dc_output |
|
features | * TEMPERATURE RANGE: OPERATING 0℃ --- 45℃,STORAGE -40℃ --- 70℃ * HOLD UP TIME: 16 ms MINIMUM AT FULL LOAD & 90VAC INPUT VOLTAGE * EFFICIENCY: 70% TYPICAL AT 115VAC, FULL LOAD * POWER GOOD SIGNAL: ON DELAY 100 ms TO 500 ms, OFF DELAY 1 ms * OVER POWER PROTECTION * OVER VOLTAGE PROTECTION * OVER CURRENT PROTECTION * SHORT CIRCUIT PROTECTION * EMI NOISE FILTER: FCC CLASS B, CISPR22 CLASS B * FAULTY ALARM METHODS: LED, BUZZER, TTL SIGNAL * WARNING METHOD: AUDIO ALARM, POWER DETECTIVE SIGNAL DELIVERY * REMOTE SENSING DESIGN * ISOLATION: BUILT-IN THE POWER MODULE *THE POWER-SUPPLY IS FOR CHASSIS-ASSEMBLY ONLY AND IS NOT ALLOWED TO BE OPERATED AS STAND-ALONE COMPONENT. FINAL ASSEMBLY HAS TO COMPLY WITH CORRESPONDING EMC- AND SAFETY-REGULATIONS. |
CCC:http://www.zippy.com.tw//backend/DownLoad/DownLoad/Power/CCC/M1L%20&%20M1L2%20CCC.pdf CB:http://www.zippy.com.tw//backend/DownLoad/DownLoad/Power/CB/M1L%20&%20M1L2%20CB.pdf TUV:http://www.zippy.com.tw//backend/DownLoad/DownLoad/Power/TUV/M1L%20&%20M1L2%20TUV.pdf DRAWING:http://www.zippy.com.tw//backend/DownLoad/DownLoad/Power/DRAWING/M1L2MA00.pdf FCC:http://www.zippy.com.tw//backend/DownLoad/DownLoad/Power/FCC/M1L2-5650P3V%20FCC.pdf CE(Radiation):http://www.zippy.com.tw//backend/DownLoad/DownLoad/Power/CE/M1L2-5650P3V%20(+Radiation).pdf |