製品情報

M1W2-5600P3V(600W)

製品種別 電源 (Zippy)
電源の種類 2U Redundant
製品説明

製品仕様

wattage 600W
solution Server ,Workstation ,Storage System
dimension_mm 300x101x84
dimension_inch 11.81x3.98x3.31
input_spec VOLTAGE: 90~264 VAC FULL RANGE FREQUENCY: 47~63Hz INPUT CURRENT: 10-5A MAX AT ANY LOW/HIGH INPUT VOLTAGE INRUSH CURRENT: 160/180A @ 115/230VAC (25℃) POWER FACTOR CORRECTION: 95% @ 110V, FULL LOAD
dc_output Output VoltageOutput Current Min.Output Current Max.Regulation LoadRegulation LineOutput Ripple & Noise Max.[P-P]+5V132±5%±1%50mV+12V242±5%±1% 70mV -12V01±5%±1%70mV+3.3V124±5%±1%50mV+5VSB0.12±5%±1%50mV


features * TEMPERATURE RANGE: OPERATING: 0℃ --- 40℃
STORAGE: -20℃ --- 80℃
* HOLD UP TIME: 16 ms MINIMUM AT FULL LOAD & NORMAL INPUT VOLTAGE
* EFFICIENCY: 67% TYPICAL AT 115VAC FULL LOAD
* POWER GOOD SIGNAL: ON DELAY 100 ms TO 500 ms, OFF DELAY 1 ms
* OVER POWER PROTECTION
* OVER VOLTAGE PROTECTION
* OVER CURRENT PROTECTION
* SHORT CIRCUIT PROTECTION
* EMI NOISE FILTER: FCC CLASS A, CISPR22 CLASS A
* 3.3V / 5V REMOTE SENSING


*THE POWER-SUPPLY IS FOR CHASSIS-ASSEMBLY ONLY AND IS NOT ALLOWED TO BE OPERATED AS STAND-ALONE COMPONENT. FINAL ASSEMBLY HAS TO COMPLY WITH CORRESPONDING EMC- AND SAFETY-REGULATIONS.
pdf CB:http://www.zippy.com.tw//backend/DownLoad/DownLoad/Power/CB/R2W,%20M1WX%20600W%20CB.pdf TUV:http://www.zippy.com.tw//backend/DownLoad/DownLoad/Power/TUV/M1WX%20600W%20TUV.pdf CCC:http://www.zippy.com.tw//backend/DownLoad/DownLoad/Power/CCC/R2W,%20M1WX%20600W%20CCC.pdf MTBF:http://www.zippy.com.tw//backend/DownLoad/DownLoad/Power/MTBF/M1W2-5600P3V.pdf DRAWING:http://www.zippy.com.tw//backend/DownLoad/DownLoad/Power/DRAWING/M1W2MA00.pdf FCC:http://www.zippy.com.tw//backend/DownLoad/DownLoad/Power/FCC/M1W2-5600P3V%20FCC.pdf MTBF(RoHS):http://www.zippy.com.tw//backend/DownLoad/DownLoad/Power/MTBF/M1W2-5600P3V(RoHS).pdf