製品情報

DM1P2-5500V4V(500W)

製品種別 電源 (Zippy)
電源の種類 2U Redundant DC
製品説明

製品仕様

wattage 500W
solution Server ,Workstation ,Storage System
dimension_mm 217x85x84
dimension_inch 8.54x3.35x3.31
input_spec VOLTAGE:-36 ~ -72VDC STEADY-STATE CURRENT: 14A @ -48VDC INRUSH CURRENT: 40A MAX. @-48VDC INPUT (AT 25DEGREES AMBIENT COLD START) START UP CURRENT: 24AMPS MAX.@28VDC INPUT (AT 25 DEGREES AMBIENT COLD START)
dc_output Output VoltageOutput Current Min.Output Current Max.Regulation LoadRegulation LineOutput Ripple & Noise Max.[P-P]+5V0.532±5%±1%50mV+12V241±5%±1% 120mV -12V0.10.5±10%±1%120mV+3.3V0.525±5%±1%50mV+5VSB0.13.5±5%±1%50mV
* +5V AND +3.3V TOTAL OUTPUT MAX: 170W

features * TEMPERATURE RANGE:OPERATING 0℃~40℃, STOREAGE -20℃~80℃
* HOLD UP TIME:1mS IN REGULATOIN LIMIT AT NORMAL INPUT VOLTAGE (DC -48V)
* EFFICIENCY(PER SET):POWER SUPPLY EFFICIENCY TYPICAL 80% AT 48VDCin, FULL LOAD
* OUTPUT PROTECTION: OPP / OVP / SCP / OCP
* REMOTE ON / OFF CONTROL
* BALANCE LOAD SHARING DESIGN
* HOT-SWAPPABLE/HOT PLUGGABLE REDUNDANCY FUNCTION
* ISOLATION: BUILT-IN THE POWER MODULE
* FAULTY ALARM METHODS: BUZZER, TTL SIGNAL
* EMI: IEC61000-3-2, FCC, CISPR 22(EN 55022)
* EMS: EN 61000-4-2 ESD, EN61000-4-4 EFT, EN61000-4-5 SURGE
* SAFETY APPROVAL: UL, CUL, TUV, CCC

* THE POWER-SUPPLY IS FOR CHASSIS-ASSEMBLY ONLY AND IS NOT ALLOWED TO BE OPERATED AS STAND-ALONE COMPONENT. FINAL ASSEMBLY HAS TO COMPLY WITH CORRESPONDING EMC- AND SAFETY-REGULATIONS.
pdf DRAWING:http://www.zippy.com.tw//backend/DownLoad/DownLoad/Power/DRAWING/DM1P2MA00.pdf MTBF(RoHS):http://www.zippy.com.tw//backend/DownLoad/DownLoad/Power/MTBF/DM1P2-5500V4V(RoHS).pdf