G1W2-5C00V2V(1200W)
製品種別 | 電源 (Zippy) |
---|---|
電源の種類 | 2U Redundant |
製品説明 |
製品仕様
wattage | 1200W |
---|---|
solution | Server ,Workstation ,Storage System ,IPC |
dimension_mm | 300x101.2x84 |
dimension_inch | 11.81x3.98x3.31 |
input_spec | VOLTAGE: 90~264VAC FULL RANGE FREQUENCY: 47~63HZ INPUT CURRENT: 15A (RMS) FOR 115V / 7A (RMS) FOR 230V INRUSH CURRENT (PER POWER MODULE):60/80 AMPS@115/230 VAC (at 25 degrees ambient cold start for each power unit) PFC: Up to the target of 95% @115/230VAC, full load |
dc_output |
|
features | * TEMPERATURE RANGE:OPERATING 0℃~40℃, STORAGE -20℃~80℃ * EFFICIENCY:82% AT 230V FULL LOADING * POWER GOOD SIGNAL:ON DELAY 100mS TO 500Ms * OVER POWER PROTECITON: 110~150% * OVER VOLTAGE PROTECTION * OVER CURRENT PROTECTION * REMOTE ON/OFF CONTROL * FAULTY ALARM METHODS: LED, BUZZER, TTL SIGNAL * EMI NOISE FILTER: FCC CLASS B , CISPR 22 CLASS B * MEET IEC 61000-3-2 CLASS D (ACTIVE PFC) * SAFETY:TO MEET UL, CUL, TUV, CCC *THE POWER-SUPPLY IS FOR CHASSIS-ASSEMBLY ONLY AND IS NOT ALLOWED TO BE OPERATED AS STAND-ALONE COMPONENT. FINAL ASSEMBLY HAS TO COMPLY WITH CORRESPONDING EMC- AND SAFETY-REGULATIONS. |
TUV:http://www.zippy.com.tw//backend/DownLoad/DownLoad/Power/TUV/T1W2-V,%20CDW2-V,G1W2-V,G1F2-V%20TUV.pdf CB:http://www.zippy.com.tw//backend/DownLoad/DownLoad/Power/CB/T1W2-V,%20CDW2-V,C2W,G1W2-V%20CB.pdf CB:http://www.zippy.com.tw//backend/DownLoad/DownLoad/Power/CB/T1W2-V,%20CDW2-V,G1W2-V%20CB.pdf CCC:http://www.zippy.com.tw//backend/DownLoad/DownLoad/Power/CCC/T1W2-V,%20CDW2-V,G1W2-V,G2W-V%20CCC.pdf TUV:http://www.zippy.com.tw//backend/DownLoad/DownLoad/Power/TUV/T1W2-V,%20CDW2-V,G1W2-V,G1F2-V%20TUV.pdf MTBF(RoHS):http://www.zippy.com.tw//backend/DownLoad/DownLoad/Power/MTBF/G1W2-5C00V2V(RoHS).pdf |