NEW
SYS-110D-14C-FRDN8TP
製品種別 | サーバ |
---|---|
CPUソケット数 | 1 |
CPU | |
筐体サイズ | 1U |
最大GPU数 | |
電源仕様 | DC電源 (or ACアダプタ) |
用途/特長 | |
製品説明 | 【主な特徴】 インテル® Xeon® プロセッサー D-2766NT、CPU TDP 97W
最大256GB Registered ECC RDIMM、DDR4-2667MHz、最大512GB LRDIMM LRDIMM、DDR4-2667MHz、DIMMスロット4基搭載
2x内蔵2.5インチドライブベイ(2x PCIe 4.0 NVMe x8 SlimSASおよび1x OCuLinkオプション)
4x GbE、2x 25G SFP28および2x 10G Base-T
1x M.2 M-Key 2242/2280 (SATA/PCIe 3.0 x4)
5x 40x56mm ホットスワップ逆回転PWMファン
冗長600W、-48Vdc |
製品仕様
Product SKUs | SuperServer SYS-110D-14C-FRDN8TP (Silver) Super X12SDV-14C-SPT8F |
---|---|
Processor | CPU | Single FCBGA-2579 Intel® Xeon® Processor D-2700 Series Support CPU TDP 97W |
System Memory | Memory | Memory Capacity: 4 DIMM slots Up to 256/512GB: ECC RDIMM/LRDIMM Memory Type: 2667MHz ECC DDR4 RDIMM/LRDIMM |
Memory Voltage | 1.2 V |
Error Detection | ECC |
On-Board Devices | Chipset | Intel® SoC |
Network Connectivity | 4x 1GbE GbE 2x 25GbE SFP28 2x 10GbE Base-T |
IPMI | Support for Intelligent Platform Management Interface v.2.0 IPMI 2.0 with virtual media over LAN and KVM-over-LAN support |
Input / Output | Video | 1 VGA port(s) |
マネージメント | Software | SuperDoctor® 5 IPMI 2.0 |
Power Configurations | ACPI Power Management Power-on mode for AC power recovery |
システム監視機能 | CPU | Monitors for CPU Cores, Chipset Voltages, Memory |
FAN | Fans with tachometer monitoring Pulse Width Modulated (PWM) fan connectors Status monitor for speed control |
Temperature | CPU thermal trip support, PEPI Monitoring for CPU and chassis environment |
シャーシ | Form Factor | 1U Rackmount |
Model | CSE-515M-R000NP2 |
外形寸法・重量 | Height | 1.7" (43mm) |
Width | 17.2" (437mm) |
Depth | 15.7" (399mm) |
Package | 7.9" (H) x 26.7" (W) x 23.8" (D) |
Weight | Net Weight: 18 lbs (8.16 kg) Gross Weight: 29 lbs (13.15 kg) |
Available Color | Silver |
フロントパネル | Buttons | Power On/Off UID button |
LEDs | HDD activity LAN1 activity LAN2 activity Power status System information |
Expansion Slots | PCI-Express (PCIe) | 1 PCIe Gen 4 x16 FHFL slot(s) |
Drive Bays / Storage | Drive Bays | 2x 2.5" SATA/PCIe drive bays |
M.2 | 1 M.2 NVMe OR 1 M.2 SATA3 M-Key, 2242/2280 |
冷却機構 | Fans | 5 Counter-rotating, Hot-swappable 40x40x56mm Fan(s) |
Power Supply | 1U 600W Redundant short depth DC48V input redundant power supply |
Total Output Power | 600W : (-44) - (-65) Vdc |
Dimension(W x H x L) | 54.5 x 40 x 220 mm |
+12V | Max: 50A |
5V SB | Max: 3A / Min: 0A |
動作環境 | Environmental Spec. | Operating Temperature: 0°C ~ 40°C (32°F ~ 104°F) Non-operating Temperature: -40°C to 70°C (-40°F to 158°F) Operating Relative Humidity: 8% to 90% (non-condensing) Non-operating Relative Humidity: 5% to 95% (non-condensing) |
パーツ仕様
Standard Parts (Bulk Package) | |||
---|---|---|---|
型番 | 数量 | 内容 | |
Motherboard / Chassis | MBD-X12SDV-14C-SPT8F | 1 | Super X12SDV-14C-SPT8F Motherboard |
CSE-515M-R000NP2 | 1 | 1U Chassis | |
Cable | CBL-0483L | 2 | 29CM 30AWG SATA S/S CBL |
CBL-OTHR-1214-24 | 4 | "FAN cbl,1x4,M, to 1x4,F,14CM,3A/pin,22AWG,RoHS" | |
CBL-PWCD-0974 | 2 | "48VDC input power cable, 2M, 12AWG, 3 wires, RoHS/REACH,RoHS" | |
CBL-0191L | 1 | "FRONT CTL CABLE 20 PIN TO 20 PIN W/TUBE,50CM,PBF" | |
CBL-OTHR-1214-24 | 3 | "FAN cbl,1x4,M, to 1x4,F,14CM,3A/pin,22AWG,RoHS" | |
CBL-PWCD-0160-IS | 2 | "PWCD,US,NEMA5-15P TO IEC60320 C13,6FT,16AWG,RoHS/REACH" | |
Fan | FAN-0207L4 | 2 | "40x40x56 mm, 13K-11K RPM,Counter-rotating, Hot-swappable Fan" |
FAN-0207L4 | 3 | "40x40x56 mm, 13K-11K RPM,Counter-rotating, Hot-swappable Fan" | |
Parts | MCP-260-00099-0B | 1 | 1U Black I/O Shield for A2SDi-TP8F with EMI Gasket |
MCP-260-00078-0B | 1 | "1U I/O shield for X11 Server MB with 5X5mm vent hole and EMI Gasket, Black" | |
Air Shroud | MCP-310-51504-0B | 1 | Mylar Air Shroud for SC515M + X11 SDW |
Manual | MNL-2541-QRG | 1 | 110D-4C/8C/16C/20C-FRA(D)N8TP Quick Reference Guide |
Power Supply | PWS-601D-1R | 2 | "-48V DC input, 12V and 5Vsb 600W output for 1U redundancy" |
Riser Card | RSC-S-6G4 | 1 | "1U LHS Standard riser card with one PCIe 4.0 x16 slot,HF,Ro" |
*Power Distributor | PDB-PT515M-2424 | 1 | 1U support redundancy up to 800W for SC515M chassis with ATX |
*Drive Tray(s) | MCP-220-00137-0N | 1 | Dual 2.5 HDD bracket (bracket base follow std 2.5 |
*Rear Window | MCP-240-51505-0N | 1 | Rear window for SC515M Redundant PWS chassis |
*Front Panel | MCP-280-80901-0N | 1 | SC809 FRONT CONTROL PANEL ASSY |
*Rail Set | MCP-290-00102-0N | 1set | "Outer rail, quick-release type, 25.6" |
MCP-290-00108-0B | 1 set | "Inner rail, front, short (quick) for 1U 17.2" | |
*Fan Holder | MCP-320-51501-0N | 2 | 1U hot-swap 4056 dummy fan tray for SC515M (no venting hole) |
MCP-320-51502-0N | 1 | 1U hot-swap 4056 fan tray for FAN-0207L4 in SC515M (with venting hole) |