SYS-110P-WR
製品種別 | サーバ |
---|---|
CPUソケット数 | 1 |
CPU | |
筐体サイズ | 1U |
最大GPU数 | |
電源仕様 | リダンダント電源 |
用途/特長 | |
製品説明 | Key Applications - Virtualization - Cloud Computing - Enterprise Server - Data Center Optimized - Database Processing and Storage |
製品仕様
Product SKUs | SYS-110P-WR | SuperServer SYS-110P-WR (Black) |
---|---|
マザーボード | Super X12SPW-F |
Processor | CPU | Single Socket P+ (LGA 4189) Support Intel® 3rd Gen Xeon® Scalable Processors Support CPU TDP 270W |
Cores | Up to 36C/72T; Up to 60MB Cache |
System Memory | Memory | Memory Capacity: 8 DIMM slots Up to 2TB: 8x 256 GB DRAM Up to 3TB: 4x 256 GB DRAM and 4x 512 GB PMem Memory Type: 3200/2933/2666MHz ECC DDR4 RDIMM;LRDIMM Intel® Optane™ persistent memory 200 series |
Memory Voltage | 1.25 V |
Error Detection | Yes |
On-Board Devices | SATA | SATA3 (6Gbps); RAID 0/1/5/10 support |
NVMe | NVMe; RAID 0/1/5/10 support (*VROC HW key is required) |
Chipset | Intel® C621A |
Network Connectivity | 2x 1GbE BaseT with Intel® i210 |
IPMI | Support for Intelligent Platform Management Interface v.2.0 IPMI 2.0 with virtual media over LAN and KVM-over-LAN support |
Input / Output | SATA | 10 SATA (6Gbps) port(s) |
LAN | 1 RJ45 Dedicated IPMI LAN port 2 RJ45 1GbE LAN ports |
USB | 4 USB 3.2 Gen 1 port(s) (2 front; 2 rear) 3 USB port(s) (2 headers; 1 Type A) 2 USB 2.0 port(s) (2 rear) |
Video | 1 VGA 2 port(s) |
Serial Port | 2 COM Port(s) (1 header; 1 rear) |
DOM | 2 SuperDOM (Disk on Module) port with built-in power |
BIOS | BIOS Type | AMI 32MB SPI Flash EEPROM |
マネージメント | Software | IPMI2.0 Redfish API SSM Intel® Node Manager SPM KVM with dedicated LAN SUM NMI |
Power Configurations | ACPI/APM Power Management |
システム監視機能 | CPU | 7+1 Phase-switching voltage regulator Monitors for CPU Cores, Chipset Voltages, Memory |
FAN | Fans with tachometer monitoring Pulse Width Modulated (PWM) fan connectors Status monitor for speed control |
Temperature | Monitoring for CPU and chassis environment Thermal Control for fan connectors |
シャーシ | Form Factor | 1U Rackmount |
Model | CSE-116TS-R706WBP4 |
外形寸法・重量 | Height | 1.7" (43mm) |
Width | 17.2" (437mm) |
Depth | 23.5" (597mm) |
Package | 8" (H) x 24" (W) x 32" (D) |
Weight | Net Weight: 25 lbs (11.34 kg) Gross Weight: 38 lbs (17.24 kg) |
Available Color | Black |
フロントパネル | Buttons | Power On/Off UID button |
LEDs | Device Activity LAN 1 Activity LAN 2 Activity Power status System information |
Expansion Slots | PCI-Express (PCI-E) | Slot 1: PCI-E 4.0 x16 FHFL Slot 2: PCI-E 4.0 x16 FHFL Slot 3: PCI-E 4.0 x16 LP |
Drive Bays / Storage | Drive Bays | 10x 2.5" SATA drive bays (4x 2.5" NVMe hybrid) |
M.2 | 1x PCI-E 3.0 x 4 and SATA M-key, 2280, 22110 |
冷却機構 | Fans | 1 AOC cooling Fan(s) (optional) 5 counter-rotation PWM 40x40x56mm Fan(s) |
Power Supply | Total Output Power | 750W |
Dimension(W x H x L) | 54.5 x 40.25 x 320 mm |
AC Input | 750W: 100-240Vac / 3.8A-8A / 50-60Hz |
+12V | Max: 62A / Min: 0.5A |
5V SB | Max: 3A / Min: 0A |
Output Type | Gold Finger Connector |
Certification | |
動作環境 | Environmental Spec. | Operating Temperature: 10°C ~ 35°C (50°F ~ 95°F) Non-operating Temperature: -40°C to 70°C (-40°F to 158°F) Operating Relative Humidity: 8% to 90% (non-condensing) Non-operating Relative Humidity: 5% to 95% (non-condensing) |
パーツ仕様
パーツリスト | |||
---|---|---|---|
型番 | 数量 | 内容 | |
Motherboard / Chassis | MBD-X12SPW-F CSE-116TS-R706WBP4 | 1 1 |
Super X12SPW-F Motherboard 1U Chassis |
Backplane | BPN-SAS3-LB16A-N10 | 1 | 1U 10-Slot SFF Hybrid Backplane Supports 10xSAS3/SATA3/NVMe4 Storage Devices with 1x(2x4) + 2x(1x4) + 1x(2x2) Power Connectors |
Cable 1 | CBL-SAST-1234A-100 | 1 | SlimSAS x4 (STR) to 4x SATA,65CM,100 OHM,RoHS |
Cable 2 | CBL-SAST-1285-100 | 2 | Slimline x4 (STR) to MiniSAS HD (STR) x4,85CM,100 OHM,R |
FAN 1 | FAN-0141L4 | 1 | 40x40x56 mm 20.5K RPM / 17.6K RPM Counter-rotating Fan |
Manual | MNL-2265-QRG | 1 | 110P-WTR Quick Reference Guide |
Riser Card | RSC-W-66G4 | 1 | 1U LHS WIO Riser card with two PCI-E 4.0 x16 slots,HF,RoHS |
Riser Card | RSC-WR-6 | 1 | 1U RHS WIO Riser card with one PCI-E 4.0 x16 slot,HF,RoHS |
Software | SFT-OOB-LIC | 1 | License key for enabling OOB BIOS management |
Heatsink / Retention | SNK-P0077P | 1 | 1U Passive CPU Heat Sink for X12 Generation Intel Whitley and Cedar Island Platforms |
*Power Supply | PWS-706P-1R | 2 | 1U 750W redundant power width 54.5mm(Platinum),HF,RoHS/REACH,PBF |
*Power Distributor | PDB-PT112-S2424 | 1 | WIO X11 Support,PDB-PT112-S2424 is based on PDB-PT112-2424 |
*Cable 3 | CBL-0160L | 2 | US POWER CORD 16AWG, PB FREE |
*Cable 4 | CBL-0335L | 1 | FRONT CTL CABLE 20 PIN TO 20 PIN W/TUBE,70CM,PBF |
*FAN 2 | FAN-0141L4 | 4 | 40x40x56 mm 20.5K RPM / 17.6K RPM Counter-rotating Fan |
*Front Panel | FPB-FP116-DU3 | 1 | Front control board with two USB 3.0 for SC116/SC119X |
*Parts | MCP-120-00029-0N | 2 | Blank FH L bracket without SCSI cutout for SC815,823 |
*Parts | MCP-120-00030-0N | 1 | Blank LP L-bracket (1 raw of capsule hole) |
*Drive Tray(s) | MCP-220-00047-0B | 1 0 |
Black gen 3rd hot-swap 2.5inch HDD tray |
*Rear Window | MCP-240-00098-0N | 1 | WIO rear window for SC113,SC116, SC815 Redundant PWS |
*Power Supply | MCP-250-00009-0N | 1 | SC113 Redundant Power Distributor Cover |
*Rail Set | MCP-290-00063-0N | 1set | Rail set, quick/quick, default for 1U 17.2"W for SC113/SC116,RoHS/REACH |
*Air Shroud | MCP-310-19002-0N | 1 | SC815/113/116 Intel DP X9, X8 PC air shroud, 12x13MB |
*Fan Holder | MCP-320-00027-0B | 2 4 |
Plastic pin for 40x28, 40x56 fan |
*Fan Holder | MCP-320-00028-0B | 1 | Fan holder for 6pcs 40x56 fan, assemble-able for SC819/SC119/SC818/SC116 |
*Fan Holder | MCP-340-00035-0B | 2 | Dummy fan 40x56mm for 40x56 counter-rotating fan (cost-effective) |
オプションパーツリスト | |||
型番 | 数量 | 内容 | |
CacheVault | BTR-TFM8G-LSICVM02 + MCP-240-00203-0N (For S3108) | 1 | CacheVault for Broadcom 3108 with SuperCap mounting bracket for PCI-E location |
BTR-CV3916-1U1 (For S3908/S3916) | 1 | CacheVault for Broadcom 3908/3916 with SuperCap mounting in 1U 40x56 fan tray | |
BTR-CVPM05 + MCP-240-00203-0N (For S3908/S3916) | 1 | CacheVault for Broadcom 3908/3916 with SuperCap mounting bracket for PCI-E location | |
BTR-CV3108-1U1 (For S3108) | 1 | CacheVault for Broadcom 3108 with SuperCap mounting in 1U 40x56 fan tray | |
Cooling Fan | FAN-0141L4 | 1 | 40x40x56 mm, 20.5K RPM / 17.6K RPM, Counter-rotating Fan |
Front Bezel | MCP-210-11601-0B | 1 | Black Front Bezel |
Inlet Thermal Sensor | MCP-280-00033-0N | 1 | Universal Thermal sensor kit with 80cm I2C cable |
Intel VROC RAID Key for NVMe | AOC-VROCPREMOD | 1 | Premium Upgrade module (Intel + 3rd party Vendor SSD); RAID 0/1/10/5 |
AOC-VROCSTNMOD | 1 | Standard Upgrade module (Intel + 3rd party Vendor SSD); RAID 0/1/10 | |
AOC-VROCINTMOD | 1 | Intel SSD Only Upgrade module; RAID 0/1/10/5 | |
NVMe Cable(s) | CBL-SAST-1231-85 | - | Slimline x8 (STR) to Slimline x8 (STR),INT,30CM, 85 OHM |
NVMe Drive Try(s) | MCP-220-00167-0B | - | Tool-less Hot-swap Gen-3 NVMe drive tray, Orange tab, Black |
Software | SFT-DCMS-Single | 1 | DataCenter Management Package (per node license) |
Storage Control Card and Cable(s) | AOC-S3916L-H16iR-32DD + 2x CBL-SAST-1261-100 | 1 | Standard LP, 16 internal ports (12Gb/s) PCI-E 4.0 x8, 32HDD; RAID 0, 1, 5, 6, 10, 50, 60 |
AOC-S3908L-H8iR-16DD + 1x CBL-SAST-1261-100 | 1 | Standard LP, 8 internal ports (12Gb/s) PCI-E 4.0 x8, 16HDD; RAID 0, 1, 5, 6, 10, 50, 60 | |
AOC-S3108L-H8iR-16DD | 1 | Standard LP, 8 Internal ports (12Gb/s) PCI-E 3.0 x8, 16HDD; RAID 0, 1, 5, 6, 10, 50, 60 | |
AOC-S3008L-L8I | 1 | Standard LP, 8 internal ports (12Gb/s) PCI-E 3.0 x8, 63HDD; RAID 0, 1, 10 | |
Storage Control Card and Cable(s) (HBA) | AOC-S3008L-L8E | 1 | Standard LP, 8 internal ports (12Gb/s) PCI-E 3.0 x8, 122HDD; HBA |
AOC-S3816L-L16IT + 2x CBL-SAST-1261-100 | 1 | Standard LP, 16 internal ports (12Gb/s) PCI-E 4.0 x8, 122HDD; HBA | |
AOC-S3808L-L8IT + 1x CBL-SAST-1261-100 | 1 | Standard LP, 8 internal ports (12Gb/s) PCI-E 4.0 x8, 122HDD; HBA | |
TPM | AOM-TPM-9671V-S-O | 1 | TPM 1.2, vertical form factor, provisioned for server |
AOM-TPM-9670V-S-O | 1 | TPM 2.0, vertical form factor, provisioned for server |