NEW
SYS-220TP-HC8TR
| 製品種別 | サーバ |
|---|---|
| CPUソケット数 | 2 |
| CPU | |
| 筐体サイズ | 2U |
| 最大GPU数 | |
| 電源仕様 | リダンダント電源 |
| 用途/特長 | |
| 製品説明 | High Performance Computing Hyper-Converged Infrastructure Big Data / Big Science |
製品仕様
| Product SKUs | SYS-220TP-HC8TR | SuperServer SYS-220TP-HC8TR (Black front & sliver body) |
|---|---|
| マザーボード | Super X12DPT-PT6 |
| Processor (per Node) | CPU | Dual Socket P+ (LGA 4189) 3rd Gen Intel® Xeon® Scalable processors Support CPU TDP 185W * |
| Cores | Up to 32C/64T; Up to 48MB Cache |
| Note | *Please contact Supermicro Technical Support for supporting conditions of high power (TDP 150W and above) or high base frequency (3.0 GHz and above) processors. |
| System Memory (per Node) | Memory | Memory Capacity: 16 DIMM slots Up to 4TB: 16x 256 GB DRAM Memory Type: 3200/2933/2666MHz ECC DDR4 RDIMM |
| Memory Voltage | 1.2 V |
| Error Detection | ECC |
| On-Board Devices (per Node) | Chipset | Intel® C621A |
| Network Connectivity | 2x 10GbE BaseT with Intel® X710-AT2 |
| IPMI | Support for Intelligent Platform Management Interface v.2.0 IPMI 2.0 with virtual media over LAN and KVM-over-LAN support |
| Input / Output (per Node) | LAN | 1 RJ45 Dedicated IPMI LAN port |
| USB | 2 USB 3.0 port(s) (2 rear) |
| Video | 1 VGA port(s) |
| Others | M.2 2 NVME M.2 (up to 22x80 mm) support via installed SCC-P2N2M2-P2 and M.2 for OS boot only. |
| BIOS | BIOS Type | AMI 32MB SPI Flash EEPROM |
| マネージメント | Software | Supermicro Out of Band (OOB) Software License Key (Included per Node) Redfish API IPMI 2.0 SSM Intel® Node Manager SPM KVM with dedicated LAN SUM NMI Watch Dog SuperDoctor® 5 |
| Power Configurations | ACPI/APM Power Management ACPI Power Management Power-on mode for AC power recovery |
| システム監視機能 | CPU | 5 Phase-switching voltage regulator Monitors for CPU Cores, Chipset Voltages, Memory |
| FAN | Fans with tachometer monitoring Pulse Width Modulated (PWM) fan connectors Status monitor for speed control |
| Temperature | Monitoring for CPU and chassis environment Thermal Control for fan connectors |
| シャーシ | Form Factor | 2U Rackmount |
| Model | CSV-217HQ+-R2K20BP4 |
| 外形寸法・重量 | Height | 3.47" (88mm) |
| Width | 17.25" (438mm) |
| Depth | 28.75" (730mm) |
| Package | 10" (H) x 24.5" (W) x 45" (D) |
| Weight | Net Weight: 72 lbs (32.7 kg) Gross Weight: 90 lbs (40.9 kg) |
| Available Color | Black front & sliver body |
| フロントパネル | Buttons | Power On/Off button UID button |
| LEDs | Network activity LED Power status LED System information (overheat/UID) LED |
| Expansion Slots (per Node) | PCI-Express (PCI-E) | Slot 2: PCI-E 4.0 x16 LP Internal Slot: M.2 |
| Drive Bays / Storage (per Node) | Hot-swap | 6x 2.5" hot-swap SATA/SAS drive bays |
| 冷却機構 | Fans | 4x 8cm heavy duty fans with optimal fan speed control |
| Air Shroud | 4 Air Shroud(s) |
| Power Supply | Dimension(W x H x L) | 76 x 40 x 336 mm |
| AC Input | 1200W: 100-127Vac / 50-60Hz 2200W: 200-240Vac / 50-60Hz |
| DC Input | 2090W: 230-240Vdc for CCC only |
| +12V | Max: 100A / Min: 0A (100Vac-127Vac) Max: 183.3A / Min: 0A (200Vac-240Vac) |
| 5V SB | Max: 1A / Min: 0A |
| Output Type | Gold Finger Connector |
| Certification | |
| 動作環境 | Environmental Spec. | Operating Temperature: 10°C ~ 35°C (50°F ~ 95°F) Non-operating Temperature: -40°C to 60°C (-40°F to 140°F) Operating Relative Humidity: 8% to 90% (non-condensing) Non-operating Relative Humidity: 5% to 95% (non-condensing) |
パーツ仕様
| パーツリスト | |||
|---|---|---|---|
| 型番 | 数量 | 内容 | |
| Motherboard / Chassis | MBD-X12DPT-PT6 CSV-217HQ+-R2K20BP4 | 4 1 |
Super X12DPT-PT6 Motherboard 2U Chassis |
| Add-on Card / Module | AOC-S3808L-L8IT-P | 4 | 8 int 12Gb/s SAS3 ports, x8 Gen4, HBA - LP, 122 HDD w/ exp,RoHS |
| Backplane | BPN-SAS3-217HQ3 | 1 | 2U 4-Node TwinPro Backplane for 6x2.5â� SAS3/SATA3 HDD/SDD |
| Cable 1 | CBL-PWCD-0900 | 2 | PWCD,US/EU/Canada/China/Australia,IEC60320 C14 TO C13,4FT,17 |
| Cable 2 | CBL-SAST-1334-100 | 4 | [NR] SlimSAS x8 (STR to STR),36CM,100 OHM,RoHS |
| Air Shroud | MCP-310-21732-0B | 4 | TwinPro 2U4N plastic air shroud for X12DPT-PT6(2pcs) |
| Riser Card | RSC-P-6G4 | 4 | 1U LHS TwinPro Riser card with one PCI-E 4.0x16lotH,RoHS |
| Riser Card | RSC-PR-6-X2 | 4 | 1U RHS TwinPro Riser card with one PCI-E 4.0 x16 slot,HF,RoH |
| Storage Controller Card | SCC-P2N2M2-P2 | 4 | 2x NVMe M.2 carrier up to 2280 for X12 Twinpro |
| Storage Controller Card | SCC-P6SG4-P1 | 4 | [NR]1U Passive Gen4 6x SAS/SATA connecting to AOC 3808/3908 |
| Software | SFT-OOB-LIC | 4 | License key for enabling OOB BIOS management |
| Heatsink / Retention | SNK-P0077PM | 4 | X12 ICX/CPX 1U Passive CPU Heatsink (78x113x24.7mm), w/ Center Air channel |
| Heatsink / Retention | SNK-P0077V | 4 | X12 ICX/CPX CPU Heatsink (78x113x25.5mm), VC Base, Cu Fin |
| *Power Supply | PWS-2K20A-1R | 2 | 1U 2200W Redundant, Titanium, 76(W) X 40(H) X 336(L) mm |
| *Power Distributor | PDB-PT217-H2412 | 1 | 2U support redundancy input powers up to 2.6KW for Twin seri |
| *FAN 1 | FAN-0183L4 | 4 | 80x80x38 mm, 16.5K RPM, Non-hot-swappable Middle Cooling Fan for X11 Twin Pro, X10 and X11 Big Twin Series Servers |
| *Drive Tray(s) | MCP-220-00047-0B | 2 4 |
Black gen 3rd hot-swap 2.5inch HDD tray |
| *Rail Set | MCP-290-00053-0N | 1 | Rail set, quick/quick, default for 2,3U 17.2";W |
| *Fan Holder | MCP-320-21701-0N | 2 | Twin Pro fan holder (hold 2 80x38 fans),RoHS/REACH |
| オプションパーツリスト | |||
| 型番 | 数量 | 内容 | |
| TPM security module (optional, not included) | AOM-TPM-9671H-O | 1 | SPI capable TPM 1.2 with Infineon 9670 controller with Horizontal form factor |
| AOM-TPM-9670H-O | 1 | SPI capable TPM 2.0 with Infineon 9670 controller with Horizontal form factor | |