NEW
SYS-220P-C9RT
製品種別 | サーバ |
---|---|
CPUソケット数 | 2 |
CPU | |
筐体サイズ | 2U |
最大GPU数 | |
電源仕様 | リダンダント電源 |
用途/特長 | |
製品説明 | High Performance Computing Enterprise Server Data Center Optimized Database Processing and High Density Storage Application-Optimized Solutions |
製品仕様
Product SKUs | SYS-220P-C9RT | SuperServer SYS-220P-C9RT (Black) |
---|---|
マザーボード | Super X12DPi-NT6 |
Processor | CPU | Dual Socket P+ (LGA-4189) 3rd Gen Intel® Xeon® Scalable processors Support CPU TDP 270W |
System Memory | Memory | Memory Capacity: 16 DIMM slots UP to 4TB: PMem and DRAM Memory Type: 3200MHz ECC LRDIMM/RDIMM DDR4 Intel® Optane™ persistent memory 200 series |
On-Board Devices | Chipset | Intel® C621A |
Network Connectivity | 2x 10GbE port(s) |
IPMI | Support for Intelligent Platform Management Interface v.2.0 IPMI 2.0 with virtual media over LAN and KVM-over-LAN support |
Input / Output | LAN | 1 decicated IPMI LAN port |
USB | 2 USB 2.0 port(s) (2 front) 4 USB 3.0 port(s) (4 rear) |
Video | 1 VGA port(s) |
Serial Port | 2 COM Port(s) (1 front; 1 rear) |
DOM | 2 SuperDOM (Disk on Module) port |
BIOS | BIOS Type | AMI 32MB SPI Flash EEPROM |
マネージメント | Software | Supermicro Out of Band (OOB) License (included in the unit) IPMI2.0 Redfish API SSM Intel® Node Manager SPM KVM with dedicated LAN SUM NMI |
Power Configurations | ACPI/APM Power Management |
システム監視機能 | CPU | 4+1 Phase-switching voltage regulator Monitors for CPU Cores, Chipset Voltages, Memory |
FAN | Fans with tachometer monitoring Pulse Width Modulated (PWM) fan connectors Status monitor for speed control |
Temperature | Monitoring for CPU and chassis environment Thermal Control for fan connectors |
シャーシ | Form Factor | 2U Rackmount |
Model | CSE-213BTS-R1K23LPBP3-1 |
外形寸法・重量 | Height | 3.5" (89mm) |
Width | 17.2" (437mm) |
Depth | 24.8" (630mm) |
Package | 11" (H) x 29" (W) x 38.7" (D) |
Weight | Net Weight: 38 lbs (17.4 kg) Gross Weight: 63 lbs (28.8 kg) |
Available Color | Black |
フロントパネル | Buttons | Power On/Off System Reset |
LEDs | HDD activity Network activity Power status System information (overheat/UID) |
Expansion Slots | PCI-Express (PCI-E) | Slot 2: PCI-E 4.0 x16 LP Slot 3: PCI-E 4.0 x16 LP Slot 4: PCI-E 4.0 x16 LP Slot 5: PCI-E 4.0 x16 LP Slot 6: PCI-E 4.0 x8 LP |
Drive Bays / Storage | Hot-swap | 16x 2.5" hot-swap drive bays (8x SAS drive bays with Broadcom® 3908 HW RAID controller(backplane port# 0~7) and 8x SATA drive bays (backplane port# 8~15) with Intel® C621A (4x SATA drive bays (backplane port# 8~11) can be converted to NVMe drives with optional 2x CBL-SAST-0821-1) |
M.2 | 1 M.2 NVMe |
Peripheral Bays | 1x (slim or 5.25") DVD drive bays (optional) |
冷却機構 | Fans | 3 heavy duty fans with optimal fan speed control |
Power Supply | Dimension(W x H x L) | 76 x 40 x 336 mm |
Output Type | Gold Finger |
Certification | |
動作環境 | RoHS | RoHS Compliant |
Environmental Spec. | Operating Temperature: 10°C ~ 35°C (50°F ~ 95°F) Non-operating Temperature: -40°C to 60°C (-40°F to 140°F) Operating Relative Humidity: 8% to 90% (Non-Condensing) Non-operating Relative Humidity: 5% to 95% (Non-Condensing) |
パーツ仕様
パーツリスト | |||
---|---|---|---|
型番 | 数量 | 内容 | |
Motherboard / Chassis | MBD-X12DPi-NT6 CSE-213BTS-R1K23LPBP3-1 | 1 1 | Super X12DPi-NT6 Motherboard 2U Chassis |
Add-on Card / Module | AOC-S3908L-H8IR-16DD-P | 1 |
8 int 12Gb/s ports, x8 Gen4, ROC - LP, 16 HDD w/ exp,RoHS |
Backplane | BPN-SAS3-213A-N8 | 1 |
16-port 2U SAS3 12Gbps hybrid backplane, support up to 8x 2.5-inch SAS3/SATA3 HDD/SSD and 8x SAS3/SATA3/NVMe Storage Devices |
Cable 1 | CBL-SAST-0508-01 | 2 |
Internal Mini-SAS to Mini-SAS HD 50cm w/ SB, 30AWG |
Cable 2 | CBL-SAST-0508-02 | 2 |
Internal Mini-SAS to Mini-SAS HD 50cm w/ SB, 30AWG |
Cable 3 | CBL-SAST-1264-100 | 1 |
Slimline x8 (STR) to 2x MiniSAS HD x4,65CM,100 OHM,RoHS |
Drive Tray(s) | MCP-220-00007-01 | 1 |
Black USB/COM port tray for SC825, 836 |
Parts | MCP-260-00042-0N | 1 |
STD I/O shield for X9 socket R server MB with Gasket. |
Manual | MNL-2243-QRG | 1 |
SYS-220P-C9R(T) Quick Reference Guide |
Heatsink / Retention | SNK-P0078P | 1 |
2U Passive CPU Heat Sink for X12 Generation Intel Whitley and Cedar Island Platforms |
Heatsink / Retention | SNK-P0078PC | 1 |
2U Passive CPU Heat Sink w/ a Side Air Channel for X12 Generation Intel Whitley and Cedar Island Platforms |
*Power Supply | PWS-1K23A-1R | 2 |
AC-DC 1200W, Titanium Level, Redundancy, 1U, PMBUS 1.2, +12V/+5Vsb, 336x76x40 mm,HF,RoHS/REACH |
*Power Distributor | PDB-PT829-S8824 | 1 |
PDB with 23pairs input connectors for SC829B216B |
*Cable 4 | CBL-0071L | 1 |
ROUND 16 TO 16 PIN RIBBON FP CABLE 30"L, LF |
*Cable 5 | CBL-0217L | 1 |
16PIN CNTL PANEL CONVERTER CBL FOR SC826,PBF |
*Cable 6 | CBL-PWCD-0160-IS | 2 |
PWCD,US,NEMA5-15P TO IEC60320 C13,6FT,16AWG,RoHS/REACH |
*Cable 7 | CBL-PWEX-1069 | 3 |
PWEX,FAN,1X4/P2.5 TO 1X4/P2.54,30CM,22AWG,5A/pin,RoHS |
*FAN 1 | FAN-0206L4 | 3 |
80x80x38 mm, 13.5K RPM, Middle Cooling Fan for 2U and above Servers |
*Front Panel | FPB-FP826-D | 1 |
Front control board Dual color LED(FP826-D)forSC826,213,216,219 |
*Drive Tray(s) | MCP-220-00009-01 | 1 |
Black 5.25"; drive tray w/o rail (square pattern) |
*Drive Tray(s) | MCP-220-00023-01 | 1 |
Black USB dummy tray support 1x 2.5" slim HDD for SC825, 836 |
*Drive Tray(s) | MCP-220-00047-0B | 1 6 |
Black gen 3rd hot-swap 2.5inch HDD tray |
*Rear Window | MCP-240-82608-0N | 1 |
216B/826B LP rear window,RoHS/REACH,PBF |
*Peripheral Drive1 | MCP-290-00007-01 | 1 |
Black DVD dummy cover for SC825, 836 |
*Rail Set | MCP-290-00053-0N | 1 |
Rail set, quick/quick, default for 2,3U 17.2";W |
*Air Shroud | MCP-310-29001-0N | 1 |
SC825/826/216/213 Intel DP X9,X8 air shroud 13.68x13/12x13 |
*Front Panel | TB826 | 1 |
Front panel adaptor board (TB826) forSC826,213,216,219 |
オプションパーツリスト | |||
型番 | 数量 | 内容 | |
BTR kit for AOC-S3108L-H8IR or AOC-S3108L-H8IR-16DD with SYS-220P-C9RT | 1x BTR-TFM8G-LSICVM02 and 1x BKT-BBU-BRACKET-05 with AOC-S3108L-H8IR or AOC-S3108L-H8IR-16DD | 1 |
SuperCap and mounting bracket used for SAS raid controllers |
BTR kit for AOC-S3908L-H8IR-16DD-P and AOC-S3916L-H16R-32DD with SYS-220P-C9RT | 1x BTR-CVPM05 and 1x BKT-BBU-BRACKET-05 with AOC-S3908L-H8IR-16DD-P and AOC-S3916L-H16R-32DD | 1 |
SuperCap and mounting bracket used for SAS raid controllers |
BTR kit for Broadcom/LSI AOC-SAS3-9361-16I with SYS-220P-C9RT | 1x BTR-TFM4G-LSI00418 and 1x BKT-BBU-BRACKET-05 used with Broadcom/LSI AOC-SAS3-9361-16I | 1 |
SuperCap and mounting bracket used for SAS raid controllers |
Optional Gen3 16-ports SAS Raid controller kit for SYS-220P-C9RT | AOC-SAS3-9361-16I and 4x CBL-SAST-0593-01 or 4x CBL-SAST-0531-01 | 1 |
to use one raid controller to support all 16 drives bays, the default AOC-S3908L-H8IR-16DD-P raid controller is not used ; |
Optional Gen4 16-ports SAS Raid controller kit for SYS-220P-C9RT | 1x AOC-S3916L-H16R-32DD and 2x CBL-SAST-1264-100 | 1 |
to use one raid controller to support all 16 drives bays, the default AOC-S3908L-H8IR-16DD-P raid controller is not used |
Optional Gen3 8-ports SAS Raid controller kit for SYS-220P-C9RT | AOC-S3108L-H8IR or AOC-S3108L-H8IR-16DD + 2x CBL-SAST-0531-01 | 1 |
to convert system SATA ports# 8~15 to SAS drive support; There are two raid controllers in the system and each raid controller supports 8x SAS drives; |
Optional parts needed to support 2x fixed NVMe drives | 1x MCP-220-00160-0N (Dual 2.5" Drive BKT) and 1x CBL-SAST-0953 (Slimline x8 to PCIe 2x SFF-8639 Power) | 1 |
1x MCP-220-00160-0N can support 2x NVMe fixed drives in 1x 5.25 inch drive bay and 1x CBL-SAST-0953 can support 2x 2.5 inch NMVe drives |
Optional parts needed to support 2x fixed SATA drives | 1x MCP-220-00160-0N (Dual 2.5" Drive BKT), 2x CBL-0044L(SATA CABLE 61CM FLAT S-S PBF.26AWG flat) and 1x CBL-0082L (Y split , big 4 pin to two RA SATA power extension 15cm, 18AWG) | 1 |
1x MCP-220-00160-0N can support 2x 2.5 inch fixed drives in 1x 5.25 inch drive bay, 1x CBL-0044L can support 1x 2.5 inch SATA drives and 1x CBL-0082L can support 2x 2.5 inch SATA drives |
Optional parts needed to support 4x hotswap NVMe drives | 2x CBL-SAST-0821-1 (SLIMLINE x8 (LE) to 2x Oculink x4, 46/50CM,85 OHM,RoHS) | 1 |
1x CBL-SAST-0821-1 can support can support 2x 2.5 inch hotswap NMVe drives, system can support Max. 4x NMVe drives (hotswap and fixed combined) only |