SYS-620C-TN12R
製品種別 | サーバ |
---|---|
CPUソケット数 | 2 |
CPU | |
筐体サイズ | 2U |
最大GPU数 | |
電源仕様 | リダンダント電源 |
用途/特長 | |
製品説明 |
製品仕様
Product SKUs | SYS-620C-TN12R | SuperServer SYS-620C-TN12R (Black front & sliver body) |
---|---|
マザーボード | Super X12DDW-A6 |
Processor/Cache | CPU | Dual Socket P+ (LGA-4189) 3rd Gen Intel® Xeon® Scalable processors 3 UPI up to 11.2GT/s Support CPU TDP 270W |
Cores | Up to 40C/80T |
System Memory | Memory | Memory Capacity: 16 DIMM slots UP to 4TB: 16x 256 GB DRAM UP to 6TB: 8x 256 GB DRAM and 8x 512 GB PMem Memory Type: 3200/2933/2666MHz ECC DDR4 RDIMM;LRDIMM Intel® Optane™ persistent memory 200 series |
Memory Voltage | 1.2 V |
Error Detection | ECC |
On-Board Devices | NVMe | NVMe; RAID 0/1/5/10 support U.2 |
SATA | SATA3 (6Gbps); RAID 0/1/5/10 support |
Chipset | Intel® C621A |
Network Connectivity | Via Slim-AIOM |
IPMI | Support for Intelligent Platform Management Interface v.2.0 IPMI 2.0 with virtual media over LAN and KVM-over-LAN support |
Input / Output | LAN | 1 Dedicated IPMI LAN port |
USB | 2 USB 3.0 port(s) (2 rear) |
Video | 1 VGA port(s) |
Serial Port | 1 COM Port(s) (1 rear) |
DOM | 1 SuperDOM (Disk on Module) port |
BIOS | BIOS Type | AMI 32MB SPI FLASH ROM |
マネージメント | Software | SCC Redfish API IPMI 2.0 SSM Intel® Node Manager SPM KVM with dedicated LAN SUM NMI Watch Dog SuperDoctor® 5 |
Power Configurations | ACPI/APM Power Management |
システム監視機能 | CPU | 4+1 Phase-switching voltage regulator Monitors for CPU Cores, Chipset Voltages, Memory. |
FAN | Fans with tachometer monitorin Pulse Width Modulated (PWM) fan connectors Status monitor for speed control |
Temperature | Monitoring for CPU and chassis environment Thermal Control for fan connectors |
シャーシ | Form Factor | 2U Rackmount |
Model | CSE-LA26AC12-R1K23AW |
外形寸法・重量 | Height | 3.5" (89mm) |
Width | 17.2" (437mm) |
Depth | 25.5" (648mm) |
Package | 11.4" (H) x 26.7" (W) x 34.5" (D) |
Weight | Net Weight: 33.5 lbs (15.2 kg) Gross Weight: 60 lbs (27.2 kg) |
Available Color | Black front & sliver body |
フロントパネル | Buttons | Power On/Off button |
LEDs | HDD activity LED Network activity LEDs Power status LED Universal Information (UID) LED |
Expansion Slots | PCI-Express (PCI-E) | Slot 1: PCI-E 4.0 x8 FH, 6.6"L (optional x16 by merging slot 2) Slot 2: PCI-E 4.0 x8 FH, 6.6"L Slot 3: PCI-E 4.0 x16 FH, 6.6"L Slot 4: PCI-E 4.0 x8 FH, 6.6"L Slot 5: PCI-E 4.0 x8 FH, 6.6"L (optional x16 by merging slot 4) Slot 6: PCI-E 4.0 x16 FH, 6.6"L Slot A1: PCI-E 4.0 x16 OCP 3.0 Mezzanine NIC Slot A2: PCI-E 4.0 x16 OCP 3.0 Mezzanine NIC |
Drive Bays / Storage | Hot-swap | 12x 3.5" hot-swap NVMe/SATA/SAS drive bays (12x 2.5" NVMe hybrid) (Some PCIe expansion slots may disable to support 9 or more direct-attached NVMe drives.) U.2 drive support |
M.2 | 2 M.2 NVMe M-Key, 2280 |
冷却機構 | Fans | 3x 8cm heavy duty fans with optimal fan speed control |
Air Shroud | 1 Air Shroud(s) |
Power Supply | Dimension(W x H x L) | 76 x 40 x 336 mm |
Output Type | Gold Finger |
Certification | |
動作環境 | Environmental Spec. | Operating Temperature: 10°C ~ 35°C (50°F ~ 95°F) Non-operating Temperature: -40°C to 60°C (-40°F to 140°F) Operating Relative Humidity: 8% to 90% (non-condensing) Non-operating Relative Humidity: 5% to 95% (non-condensing) |
パーツ仕様
パーツリスト | |||
---|---|---|---|
型番 | 数量 | 内容 | |
Motherboard / Chassis | MBD-X12DDW-A6 CSE-LA26AC12-R1K23AW | 1 1 | Super X12DDW-A6 Motherboard 2U Chassis |
Backplane | BPN-SAS3-LA26A-N12 | 1 |
2U 12-Slot LFF Backplane Supports 12 x SAS3/SATA3/NVMe4 Storage Devices with 1x(2x4) + 4x(1x4) power connectors, co-lay with BPN-SAS3-LA26A-N12,HF,RoHS |
Cable 1 | CBL-SAST-1208LP-85 | 4 |
SlimlineLP x8 (STR) to SlimlineLP x8 (STR),8CM,85 OHM,Ro |
Cable 2 | CBL-SAST-1274LP-100 | 1 |
SlimlineLP x8 (LE) to 2x Slimline x4 (STR),68/76CM,100 O |
Cable 3 | CBL-SAST-1285LP-100 | 1 |
SlimlineLP x4 (STR) to Slimline x4 (STR),57CM,100 OHM,Ro |
Parts | MCP-150-00022-0B | 6 |
Rubber pad, 5mm H, 10x10mm |
Air Shroud | MCP-310-82606-0B | 1 |
Mylar air shroud X12DDW for SCLA26-AW |
Manual | MNL-2344-QRG | 1 |
620C-TN12R Quick Reference Guide |
Riser Card | RSC-D2-668G4 | 1 |
2U LHS DCO Riser card with two PCI-E 4.0 x16 and one PCI-E |
Riser Card | RSC-D2R-668G4 | 1 |
2U RHS DCO Riser card with two PCI-E 4.0 x16 and one PCI-E |
Heatsink / Retention | SNK-P0078P | 2 |
2U Passive CPU Heat Sink for X12 Generation Intel Whitley and Cedar Island Platforms |
*Power Supply | PWS-1K23A-1R | 2 |
AC-DC 1200W, Titanium Level, Redundancy, 1U, PMBUS 1.2, +12V/+5Vsb, 360x76x40 mm,HF,RoHS/REACH |
*Power Distributor | PDB-PT826-S4824 | 1 |
Based on PDB-PT826-8824 to add 2pcs 8pin for option support |
*Cable 4 | CBL-PWCD-0160-IS | 2 |
PWCD,US,NEMA5-15P TO IEC60320 C13,6FT,16AWG,RoHS/REACH |
*FAN 1 | FAN-0206L4 | 3 |
80x80x38 mm, 13.5K RPM, Middle Cooling Fan for 2U and above Servers |
*Drive Tray(s) | MCP-220-00184-0B | 1 2 |
Black gen-9 tool-less cost-effective 3.5 |
*Rear Window | MCP-240-00170-0N | 1 |
2U X12 WIO rear window for SCLA26 |
*Rail Set | MCP-290-00053-0N | 1 |
Rail set, quick/quick, default for 2,3U 17.2";W |
*Drive Tray(s) | MCP-290-82607-0N | 1 |
826B/216B rear dummy cover for 2 X 2.5 |
オプションパーツリスト | |||
型番 | 数量 | 内容 | |
3108 CacheVault | BTR-TFM8G-LSICVM02 | 1 |
CacheVault for Broadcom 3108 |
MCP-240-00127-0N | 1 | SuperCap mounting bracket for 2.5" HDD location | |
BKT-BBU-BRACKET-05 | 1 | SuperCap mounting bracket for PCI-E location | |
3108 RAID Card | CBL-SAST-1260-100 | 1 |
MiniSAS HD x8 (LE) to 2x Slimline x4 (STR),60CM |
AOC-S3108L-H8IR-16DD | 1 | Standard LP, 8 internal ports (12Gb/s) Gen-3, 16HDD; RAID 0, 1, 5, 6, 10, 50, 60 | |
3808 HBA Card | AOC-S3808L-L8IT | 1 |
Standard LP, 8 internal ports (12Gb/s) Gen-4, 16HDD; HBA; |
CBL-SAST-1276F-100 | 1 | Slimline x8 (LE) to 2x Slimline x4 (STR),76/76CM | |
3816 HBA Card | AOC-S3816L-L16IT | 1 |
Standard LP, 16 internal ports (12Gb/s) Gen-4, 122HDD; HBA; |
CBL-SAST-1265F-100 | 1 | Slimline x8 (STR) to Slimline x4 (STR),64CM | |
CBL-SAST-1276F-100 | 1 | Slimline x8 (LE) to 2x Slimline x4 (STR),76/76CM | |
3908 RAID Card | CBL-SAST-1276F-100 | 1 |
Slimline x8 (LE) to 2x Slimline x4 (STR),76/76CM |
AOC-S3908L-H8IR-16DD | 1 | Standard LP, 8 internal ports (12Gb/s) Gen-4, 122HDD; RAID 0, 1, 5, 6, 10, 50, 60; | |
3908/3916 CacheVault | BTR-CVPM05 | 1 |
CacheVault for Broadcom 3908/3916 |
MCP-240-00127-0N | 1 | SuperCap mounting bracket for 2.5" HDD location | |
BKT-BBU-BRACKET-05 | 1 | SuperCap mounting bracket for PCI-E location | |
3916 RAID Card | CBL-SAST-1265F-100 | 1 |
Slimline x8 (STR) to Slimline x4 (STR),64CM |
CBL-SAST-1276F-100 | 1 | Slimline x8 (LE) to 2x Slimline x4 (STR),76/76CM | |
AOC-S3916L-H16IR-32DD | 1 | Standard LP, 16 internal ports (12Gb/s) Gen-4, 32HDD; RAID 0, 1, 5, 6, 10, 50, 60; | |
Add-on card for additional M.2 | AOC-SLG3-2H8M2 | - | Low Profile PCI-E x8 add-on card supports 2 PCI-E 3.0 x4 M-Key M.2 NVMe/SATA Modules; RAID 0,1 |
AOC-SLG3-2M2 | - | Low Profile PCI-E x8 add-on card supports 2 PCI-E 3.0 x4 M-Key M.2 NVMe Modules | |
AIOM Network Card(s) | AOC-ATGC-i2TM | - | OCP 3.0 AIOM NIC, 2x 10GbE RJ45, PCI-E 3.0 x4, Intel X710-AT2 |
AOC-AG-i4SM | - | OCP 3.0 AIOM NIC, 4x 1GbE SFP, PCI-E 2.1 x4, Intel® i350-AM4 | |
AOC-AG-i2M | - | OCP 3.0 AIOM NIC, 2x 1GbE RJ45, PCI-E 2.1 x4, Intel® i350-AM2 | |
AOC-ATG-i2TM | - | OCP 3.0 AIOM NIC, 2x 10GbE RJ45, PCI-E 3.0 x4, Intel® X550-AT2 | |
AOC-A25G-b2SM | - | OCP 3.0 AIOM NIC, 2x 25GbE SFP28, PCI-E x8, Broadcom® BCM57414 | |
AOC-ATG-i2SM | - | OCP 3.0 AIOM NIC, 2x 10GbE SFP+, PCI-E 3.0 x8, Intel® X710-BM2 | |
AOC-A100G-b2CM | - | OCP 3.0 AIOM NIC, 2x 100GbE QSFP28, PCI-E 4.0 x16, Broadcom® BCM57508 | |
AOC-AH25G-m2S2TM | - | OCP 3.0 AIOM NIC, 2x 25GbE SFP28 & 2x 10GbE RJ45, PCI-E x8/x4, Mellanox® CX4 Lx EN & Intel® X550-AT2 | |
AOC-AG-i4M | - | OCP 3.0 AIOM NIC, 4x 1GbE RJ45, PCI-E 2.1 x4, Intel® i350-AM4 | |
AOC-ATG-i4SM | - | OCP 3.0 AIOM NIC, 4x 10GbE SFP+, PCI-E 3.0 x8, Intel® XL710-BM1 | |
AOC-A25G-m2SM | - | OCP 3.0 AIOM NIC, 2x 25GbE SFP28, PCI-E x8, Mellanox® CX-6 LX | |
AOC-ATG-i2T2SM | - | OCP 3.0 AIOM NIC, 4x 10GbE RJ45 & SFP+, PCI-E x8, Intel® X710-TM4 | |
AOC-A100G-m2CM | - | OCP 3.0 AIOM NIC, 2x 100GbE QSFP28, PCI-E 4.0 x16, Mellanox® CX-6 DX | |
Cable Management Arm | MCP-120-82601-0N | 1 |
Cable arm adapter for SCLA26-AW |
MCP-290-00073-0N | 1 | Supermicro Cable Management Arm for 2U, 3U and 4U chassis | |
GPU Support | CBL-PWEX-1040 | 2 |
PWYCB,GPU,2x4M/CPU to two (2x3F+2x1F)/PCIe,P4.2, 5CM |
MCP-310-82613-0N | 1 | Plastic air shroud X12DDW for SCLA26-AW(GPU) | |
SNK-P0077P | 2 | 1U Passive CPU Heat Sink for X12 Generation Intel Whitley and Cedar Island Platforms | |
Intel VROC Key | AOC-VROCSTNMOD | 1 |
Intel VROC Standard, RAID 0, 1, 10 |
AOC-VROCINTMOD | 1 | Intel VROC, RAID 0, 1, 5, 10 (Intel SSD Only) | |
AOC-VROCPREMOD | 1 | Intel VROC Premium, RAID 0, 1, 5, 10 | |
NVMe Cables Kit | CBL-KIT-620C-TN12R-12 | 1 |
Supports 12x NVMe drives. Kit includes: 4x CBL-SAST-1236LP-85 (NVMe drive slot # 0-7) 2x CBL-SAST-1267FLP-85 (NVMe drive slot # 8-11) |
Rear Window NVMe Drive Kit | MCP-220-82620-0N | 1 |
Rear Window Module for 2x 2.5" NVMe Drives PCIE Gen 4 |
CBL-PWEX-1276 | 1 | 1x4M/P5.08 to 2x2Micro-Fit Male,15cm | |
CBL-SAST-1236LP-85 | 1 | Slimline x8 (STR) to 2x SlimlineLP x4 (STR),40/40CM | |
Rear Window SATA Drive Kit | MCP-220-82616-0N | 1 |
Rear Window Module for 2x 2.5" SATA/SAS Drives |
Software | SFT-DCMS-Single | 1 |
DataCenter Management Package (per node license) |
TPM security module | AOM-TPM-9670V-S-FIPS | 1 |
SPI capable TPM 2.0 with Infineon 9670 controller w/ FIPS; vertical form factor |
AOM-TPM-9671V-S | 1 | SPI capable TPM 1.2 with Infineon 9670 controller; vertical form factor | |
AOM-TPM-9670V-S | 1 | SPI capable TPM 2.0 with Infineon 9670 controller; vertical form factor | |
Note: For special low power setup SKU (3 optional parts below), please contact our sales for details. | |||
Fan | FAN-0181L4 | 3 |
80x80x38 mm 9.4K RPM Chassis Middle Fan |
Power Supply | PWS-1K23A-1R | 1 |
1200W 100-240Vac, and DC240 input |
Power Supply Dummy Cover | CSE-PT0130L | 1 |
Power Supply Dummy Cover |