SYS-510P-WT
製品種別 | サーバ |
---|---|
CPUソケット数 | 1 |
CPU | |
筐体サイズ | 1U |
最大GPU数 | |
電源仕様 | シングル電源 |
用途/特長 | |
製品説明 | Virtualization Cloud Computing Enterprise Server Data Center Optimized |
製品仕様
Product SKUs | SYS-510P-WT | SuperServer SYS-510P-WT (Black) |
---|---|
マザーボード | Super X12SPW-TF |
Processor/Cache | CPU | Single Socket P+ (LGA-4189) 3rd Gen Intel® Xeon® Scalable processors Support CPU TDP 270W |
System Memory | Memory | Memory Capacity: 8 DIMM slots UP to 2TB: 8x 256 GB DRAM UP to 3TB: 4x 256 GB DRAM and 4x 512 GB PMem Memory Type: 3200/2933/2666MHz ECC DDR4 2-10GbE Intel® Optane™ persistent memory 200 series |
Memory Voltage | 1.25 V |
Error Detection | Yes |
On-Board Devices | SATA | SATA3 (6Gbps); RAID 0/1/5/10 support |
NVMe | NVMe; RAID 0/1/5/10 support |
Chipset | Intel® C621A |
Network Connectivity | 2x 10GbE BaseT with Intel® X550 |
IPMI | Support for Intelligent Platform Management Interface v.2.0 IPMI 2.0 with virtual media over LAN and KVM-over-LAN support |
BMC | ASPEED AST2600 BMC |
Input / Output | SATA | 10 SATA (6Gbps) port(s) |
LAN | 1 RJ45 Dedicated IPMI LAN port 2 RJ45 10GBase-T LAN ports |
USB | 4 USB 2.0 port(s) (2 headers; 2 rear) 5 USB 3.2 Gen 1 port(s) (2 headers; 2 rear; 1 Type A) |
Video | 1 VGA port(s) |
Serial Port | 2 COM Port(s) (1 header; 1 rear) |
DOM | 2 SuperDOM (Disk on Module) port with built-in power |
BIOS | BIOS Type | AMI 32MB SPI Flash EEPROM |
マネージメント | Software | IPMI2.0 Redfish API SSM Intel® Node Manager SPM KVM with dedicated LAN SUM NMI |
Power Configurations | ACPI/APM Power Management |
システム監視機能 | CPU | 7+1 Phase-switching voltage regulator Monitors for CPU Cores, Chipset Voltages, Memory |
FAN | Fans with tachometer monitoring Pulse Width Modulated (PWM) fan connectors Status monitor for speed control |
Temperature | Monitoring for CPU and chassis environment Thermal Control for fan connectors |
シャーシ | Form Factor | 1U Rackmount |
Model | CSE-815TS-605WBP2 |
外形寸法・重量 | Height | 1.7" (43mm) |
Width | 17.2" (437mm) |
Depth | 25.6" (650mm) |
Package | 8.5" (H) x 23.5" (W) x 33.7" (D) |
Weight | Net Weight: 22 lbs (9.98 kg) Gross Weight: 46 lbs (20.87 kg) |
Available Color | Black |
フロントパネル | Buttons | Power On/Off System Reset UID button |
LEDs | Device Activity LAN 1 Activity LAN 2 Activity Power status System information |
Expansion Slots | PCI-Express (PCI-E) | Slot 1: PCI-E 4.0 x16 FHFL Slot 2: PCI-E 4.0 x16 FHFL Slot 3: PCI-E 4.0 x16 LP |
Drive Bays / Storage | Drive Bays | 4x 3.5" NVMe/SATA drive bays (4x 3.5" NVMe hybrid) |
M.2 | 1x PCI-E 3.0 x 4 and SATA M-key, 2280, 22110 |
Peripheral Bays | 2x 2.5" drive bays |
冷却機構 | Fans | 1 AOC cooling Fan(s) (optional) 5 counter-rotation PWM 40x40x56mm Fan(s) |
Power Supply | Dimension(W x H x L) | 76 x 40.4 x 279.4 mm |
Output Type | Gold Finger |
Certification | |
動作環境 | Environmental Spec. | Operating Temperature: 10°C ~ 35°C (50°F ~ 95°F) Non-operating Temperature: -40°C to 70°C (-40°F to 158°F) Operating Relative Humidity: 8% to 90% (non-condensing) Non-operating Relative Humidity: 5% to 95% (non-condensing) |
パーツ仕様
パーツリスト | |||
---|---|---|---|
型番 | 数量 | 内容 | |
Motherboard / Chassis | MBD-X12SPW-TF CSE-815TS-605WBP2 | 1 1 | Super X12SPW-TF Motherboard 1U Chassis |
Backplane | BPN-SAS3-815TQ-N4 | 1 |
4-port 1U SAS3 12Gbps Hybrid backplane, support up to 4x 3.5-inch SAS3/SATA3/NVMe Storage Devices |
Cable 1 | CBL-SAST-0699 | 1 |
MINI SAS HD-4 SATA,12G,INT,75/75/90/90CM,75CM SB,28/30AWG,Ro |
FAN 1 | FAN-0141L4 | 1 |
40x40x56 mm 20.5K RPM / 17.6K RPM Counter-rotating Fan |
Manual | MNL-2266-QRG | 1 |
510P-WT/WTR Quick Reference Guide |
Riser Card | RSC-W-66G4 | 1 |
1U LHS WIO Riser card with two PCI-E 4.0 x16 slots,HF,RoHS |
Riser Card | RSC-WR-6 | 1 |
1U RHS WIO Riser card with one PCI-E 4.0 x16 slot,HF,RoHS |
Heatsink / Retention | SNK-P0077P | 1 |
1U Passive CPU Heat Sink for X12 Generation Intel Whitley and Cedar Island Platforms |
*Power Supply | PWS-605P-1H | 1 |
1U 600W Multi Output Power Supply PMbus |
*Cable 2 | CBL-0335L | 1 |
FRONT CTL CABLE 20 PIN TO 20 PIN W/TUBE,70CM,PBF |
*Cable 3 | CBL-PWCD-0160-IS | 1 |
PWCD,US,NEMA5-15P TO IEC60320 C13,6FT,16AWG,RoHS/REACH |
*Fan Holder | CSE-PT0135 | 1 |
FAN HOLDER FOR SIX 40X56MM COUNTER ROTATING FANS |
*Peripheral Drive1 | CSE-PT93L-B | 1 |
Black DVD dummy cover for SC813, 813M, 815, PBF-RoHS |
*FAN 2 | FAN-0141L4 | 4 |
40x40x56 mm 20.5K RPM / 17.6K RPM Counter-rotating Fan |
*FAN 3 | FAN-0163L4 | 4 |
40x40x56 mm, 23.3K-20.3K RPM, Counter-rotating Fan |
*Front Panel | FPB-FP815U | 1 |
815 UIO front control board (U) |
*Parts | MCP-120-00030-0N | 1 |
Blank LP L-bracket (1 raw of capsule hole) |
*Parts | MCP-120-00053-0N | 2 |
Blank FH L bracket w/o SCSI cutout for SC825,836,846,743 |
*Drive Tray(s) | MCP-220-00075-0B | 4 |
Black gen 5.5 hot-swap 3.5" HDD tray |
*Rear Window | MCP-240-00097-0N | 1 |
WIO rear window for SC113,SC116, SC815 Single PWS |
*Rail Set | MCP-290-00054-0N | 1set | Rail set, quick/quick, optional for 1U 17.2 |
*Air Shroud | MCP-310-19001-0N | 1 |
SC815/113/116 Intel DP X9, X8 PC air shroud,1368x13/12x13MB |
*Fan Holder | MCP-340-00035-0B | 2 |
Dummy fan 40x56mm for 40x56 counter-rotating fan (cost-effective) |
*Rail Set | MCP-290-00102-0N | 1set | Outer rail, quick-release type, 25.6\" to 33.05\" |
*Rail Set | MCP-290-00106-0N | 1set | Inner rail, front, quick-release type |
*Rail Set | MCP-290-00110-0N | 1set | Inner rail, extension (quick) for 1U 17.2 |
オプションパーツリスト | |||
型番 | 数量 | 内容 | |
3.5" to 2.5" Converter Tray(s) | MCP-220-00043-0N | - | Hot-swap Gen-4 3.5" to 2.5" HDD tray, Black |
3.5'' to 2.5" NVMe Drive Tray(s) | MCP-220-00138-0B | - | Tool-less Hot-swap Gen-5.5 NVMe 3.5'' to 2.5'' drive tray, Orange tab, Black |
Add-on Card for additional M.2 | AOC-SLG3-2H8M2 | - | Standard LP, PCI-E 3.0 x8, supports 2x NVMe/SATA M-Key M.2 Modules; RAID 0,1 |
CacheVault | BTR-CVPM05 + BKT-BBU-BRACKET-05 (For S3908) | 1 |
CacheVault for Broadcom 3908 with SuperCap mounting bracket for PCI-E location |
BTR-TFM8G-LSICVM02 + BKT-BBU-BRACKET-05 (For S3108) | 1 | CacheVault for Broadcom 3108 with SuperCap mounting bracket for PCI-E location | |
BTR-CV3108-1U1 (For S3108) | 1 | CacheVault for Broadcom 3108 with SuperCap mounting in 1U 40x56 fan tray | |
Cooling Fan | FAN-0141L4 | 1 |
40x40x56 mm, 20.5K RPM / 17.6K RPM, Counter-rotating Fan |
DC Power Supply(s) | PWS-654-1R | 2 |
650W 1U -48V DC Input Power Supply |
Hot-swap 2.5" kit (DVD slot) | MCP-220-81506-0N | 1 |
Single 2.5" SAS3 (12Gb/s) hot swap in slim DVD form factor |
Hot-swap 2.5" kit (FDD slot) | MCP-220-81504-0N | 1 |
Single 2.5" SAS3 (12Gb/s) hot swap in slim FDD form factor |
Inlet Thermal Sensor | MCP-280-00034-0N | 1 |
Universal Thermal sensor kit with 40cm I2C cable |
Intel VROC RAID Key for NVMe | AOC-VROCSTNMOD | 1 |
Standard Upgrade module (Intel + 3rd party Vendor SSD); RAID 0/1/10 |
AOC-VROCINTMOD | 1 | Intel SSD Only Upgrade module; RAID 0/1/10/5 | |
AOC-VROCPREMOD | 1 | Premium Upgrade module (Intel + 3rd party Vendor SSD); RAID 0/1/10/5 | |
NVMe Cable (Drive Bay 0-1) | CBL-SAST-1149-85 | 1 |
SLIMLINE x8 (RE) to 2x Oculink x4,INT, 49CM, 85 OHM |
NVMe Cable (Drive Bay 2-3) | CBL-SAST-1154-85 | 1 |
SLIMLINE x8 (RE) to 2x Oculink x4,INT, 54CM, 85 OHM,RoH |
Software | SFT-DCMS-Single | 1 |
DataCenter Management Package (per node license) |
Storage Control Card and Cable(s) | AOC-S3908L-H8iR-16DD + 1x CBL-SAST-1275A-100 | 1 |
Standard LP, 8 internal ports (12Gb/s) PCI-E 4.0 x8, 16HDD; RAID 0, 1, 5, 6, 10, 50, 60 |
AOC-S3108L-H8iR-16DD | 1 | Standard LP, 8 Internal ports (12Gb/s) PCI-E 3.0 x8, 16HDD; RAID 0, 1, 5, 6, 10, 50, 60 | |
AOC-S3008L-L8I | 1 | Standard LP, 8 internal ports (12Gb/s) PCI-E 3.0 x8, 63HDD; RAID 0, 1, 10 | |
Storage Control Card and Cable(s) (HBA) | AOC-S3808L-L8IT + 1x CBL-SAST-1275A-100 | 1 |
Standard LP, 8 internal ports (12Gb/s) PCI-E 4.0 x8, 122HDD; HBA |
AOC-S3008L-L8E | 1 | Standard LP, 8 internal ports (12Gb/s) PCI-E 3.0 x8, 122HDD; HBA | |
TPM | AOM-TPM-9671V-S | 1 |
TPM 1.2, vertical form factor, provisioned for server |
AOM-TPM-9670V-S | 1 | TPM 2.0, vertical form factor, provisioned for server |