製品情報

SYS-220U-TNR

製品種別 サーバ
CPUソケット数 2
CPU  
筐体サイズ 2U
最大GPU数
電源仕様 リダンダント電源
用途/特長  
製品説明 Virtualization HPC Cloud Computing High End Enterprise Server Software Defined Storage Application Tier Service Provider 5G/Telco

第3世代 Intel Xeon Scalable プロセッサーについて


Supermicroについて


製品仕様

Product SKUs
SYS-220U-TNR SuperServer SYS-220U-TNR (Black Front & Silver Body)
マザーボード
Super X12DPU-6
Processor/Cache
CPU Dual Socket P+ (LGA-4189)
3rd Gen Intel® Xeon® Scalable processors
Support CPU TDP 270W *
Cores Up to 40C/80T; Up to 60MB Cache
Note *Certain CPUs with high TDP may be supported only under specific conditions. Please contact Supermicro Technical Support for additional information about specialized system optimization
System Memory
Memory Memory Capacity: 32 DIMM slots
UP to 8TB: 32x 256 GB DRAM
UP to 12TB: 16x 512 GB PMem and 16x 256 GB DRAM
Memory Type: 3200/2933/2666MHz ECC DDR4
Intel® Optane™ persistent memory 200 series
Memory Voltage 1.2 V
Error Detection ECC
On-Board Devices
SATA SATA3 (6Gbps) via Intel® PCH 621A; RAID 0/1/5/10 support
NVMe NVMe (16GT/s); RAID 0/1/5/10 support
Chipset Intel® C621A
Network Connectivity 2x 10GbE BaseT with Intel® X710-AT2 (optional) OR
2x 10GbE BaseT and 2x 10GbE SFP+ with Intel® X710-TM4 (optional)
No NIC option supported
IPMI Support for Intelligent Platform Management Interface v.2.0
IPMI 2.0 with virtual media over LAN and KVM-over-LAN support
BMC ASPEED AST2600 BMC
Input / Output
LAN 1 RJ45 Dedicated BMC LAN port
USB 2 USB 3.0 port(s) (2 rear)
Video 1 VGA port(s)
Serial Port 1 COM Port(s) (1 rear)
DOM 2 SuperDOM (Disk on Module) port
BIOS
BIOS Type AMI 32MB SPI Flash EEPROM
マネージメント
Software Supermicro Out of Band (OOB) License
Redfish API
IPMI 2.0
Intel® Node Manager
KVM with dedicated LAN
SUM
NMI
Watch Dog
SuperDoctor® 5
Power Configurations ACPI Power Management
Power-on mode for AC power recovery
システム監視機能
CPU 4+1 Phase-switching voltage regulator
Monitors for CPU Cores, Chipset Voltages, Memory
FAN Fans with tachometer monitoring
Pulse Width Modulated (PWM) fan connectors
Status monitor for speed control
Temperature Monitoring for CPU and chassis environment
Thermal Control for fan connectors
シャーシ
Form Factor 2U Rackmount
Model CSE-219U3TS-R1K62P-T
外形寸法・重量
Height 3.5" (89mm)
Width 17.2" (437mm)
Depth 27.76" (705.3mm)
Package 9.96" (H) x 24.6" (W) x 45.43" (D)
Weight Net Weight: 37 lbs (16.8 kg)
Gross Weight: 63 lbs (28.6 kg)
Available Color Black Front & Silver Body
フロントパネル
Buttons Power On/Off 
UID button
LEDs HDD activity
LAN1 activity
LAN2 acticity
Power Fail
Power status
System information (overheat/UID) 
Expansion Slots
PCI-Express (PCI-E) Slot 1: PCI-E 4.0 x16 FH, 10.5"L
Slot 2: PCI-E 4.0 x8 FH, 10.5"L
Slot 3: PCI-E 4.0 x8 Internal LP
Slot 4: PCI-E 4.0 x16 LP
Slot 5: PCI-E 4.0 x8 FH, 10.5"L
Slot 6: PCI-E 4.0 x8 FH, 10.5"L
Slot 7: PCI-E 4.0 x8 FH, 10.5"L
Slot 8: PCI-E 4.0 x8 FH, 10.5"L
Note Optional RSC-W2-66G4 enables PCI-E x16 in slots 5, 7. Slots 6,8 will be disabled.
Drive Bays / Storage
Hot-swap 24x 2.5" hot-swap NVMe/SATA/SAS drive bays (22x 2.5" NVMe hybrid) (SAS/NVMe support requires additional parts. Please see the Optional Parts list.)
冷却機構
Fans 4x 8cm heavy duty fans with optimal fan speed control
Air Shroud 2 Air Shroud(s)
Power Supply
Dimension(W x H x L) 73.5 x 40 x 203 mm
AC Input 1000W: 100-127Vac / 50-60Hz
1600W: 200-240Vac / 50-60Hz
+12V Max: 83A / Min: 0A (100Vac-127Vac)
Max: 133A / Min: 0A (200Vac-240Vac)
12V SB Max: 2.1A / Min: 0A
Output Type AC-Input
Certification
動作環境
Environmental Spec. Operating Temperature:    10°C ~ 35°C (50°F ~ 95°F)
Non-operating Temperature:    -40°C to 60°C (-40°F to 140°F)
Operating Relative Humidity:    8% to 90% (non-condensing)
Non-operating Relative Humidity:    5% to 95% (non-condensing)

パーツ仕様

パーツリスト
型番 数量 内容
Motherboard / Chassis MBD-X12DPU-6 CSE-219U3TS-R1K62P-T 1 1 Super X12DPU-6 Motherboard 2U Chassis
Backplane BPN-NVME4-216N-S24 1
2U 24-slot all-hybrid direct-attached backplane, support 24x 2.5" NVME Gen4 / SAS / SATA storage devices.,RoHS
Cable 1 CBL-CDAT-0674 2
4 Pin to 4 Pin I2C Cable, 30cm, 26AWG, 4 Wires, Pinout 1-1
Cable 2 CBL-PWEX-0924 1
2x4,P3.0 to 2x4,P4.2,YL/RED,9.5A,24cm,16AWG,RoHS
Cable 3 CBL-PWEX-0925 2
2x4,P3.0 to 2x4,P4.2,YL/RED,9.5A,55cm,16AWG,RoHS
Cable 4 CBL-SAST-1250F-100 2
Slimline x4 (STR) to Slimline x4 (STR),FFC,INT,50CM,100
Cable 5 CBL-SAST-1270F-100 1
Slimline x4 (STR) to Slimline x4 (STR),FFC,INT,70CM,100
Riser Card RSC-W2-8888G4 1
2U LHS WIO Riser card with four PCI-E 4.0 x8 slots,HF,RoHS
Riser Card RSC-WR-6 1
1U RHS WIO Riser card with one PCI-E 4.0 x16 slot,HF,RoHS
Heatsink / Retention SNK-P0078P 2
2U Passive CPU Heat Sink for X12 Generation Intel Whitley and Cedar Island Platforms
*Power Supply PWS-1K62A-1R 2
AC-DC 1600W, Titanium Level, Redundancy, 1U, DC Output: +12V and +12Vs, 203 x 73.5 x 40 mm, AC Input: 90 - 264 VAC/47-63Hz, PMBus 1.2 with DSP controller,HF,RoHS/REACH
*Cable 6 CBL-0088L 4
10.5" 4PIN FAN POWER CORD FOR 743X-645,PBF
*Cable 7 CBL-0160L 2
US POWER CORD 16AWG, PB FREE
*FAN 1 FAN-0206L4 4
80x80x38 mm, 13.5K RPM, Middle Cooling Fan for 2U and above Servers
*FAN 2 FAN-0209L4 4
80x80x38 mm, 13.5K RPM, Middle Cooling Fan for 2U and above
*Drive Tray(s) MCP-220-00047-0B 2
4
Black gen 3rd hot-swap 2.5inch HDD tray
*Rail Set MCP-290-00057-0N 1
Rail set, quick/quick, default for 4U 17.2"; W
*Rail Set MCP-290-00060-0N 1
Threaded rail adapter default for round hole rack
*Air Shroud MCP-310-81905-0B 1
Plastic air shroud for SC819U, 119U, 829U, 219U (PWS),RoHS/REACH
*Rail Set MCP-290-00115-0N 1
Inner rail, quick-release type
*Rail Set MCP-290-00117-0N 1
Outer rail, quick-release type
オプションパーツリスト
型番 数量 内容
2 Rear 2.5" Hot-swap SATA Drive Bays (Complete System Only) MCP-240-82922-0N-OEM 1
Rear 2x 2.5" HDDs riser bracket kit for SC829U/219U, tool-less
Add-on card for M.2 support AOC-SLG3-2H8M2-O - 2x Hybrid NVMe/SATA M.2 RAID Carrier, Standard LP,RoHS
CacheVaults BTR-CVPM05 + BKT-BBU-BRACKET-05 - CacheVault for Broadcom 3908/3916 with Supercap
BTR-CV3108-U1 - CacheVault for Broadcom 3108 with Supercap mounting for 2U Ultra
Drive Tray MCP-220-00167-0B 1 ~ 22 2.5 drive tray, Orange tab (for hotswap NVMe drive)
Global Services & Support OSNBD3/2/1 - 3/2/1-year onsite NBD service
OS4HR3/2/1 - 3/2/1-year onsite 24x7x4 service
Intel® VROC RAID Key Options AOC-VROCPREMOD 1
Intel VROC Premium, RAID 0, 1, 5, 10
AOC-VROCSTNMOD 1 Intel VROC Standard, RAID 0, 1, 10
AOC-VROCINTMOD 1 Intel VROC, RAID 0, 1, 5, 10 (Intel SSD Only)
NVMe Support Kit CBL-KIT-220U-TNR-8   1
8 NVMe Support Kit for X12 Ultra SYS-220U-TNR
CBL-KIT-220U-TNR-22N + 3 AOC-SLG4-4E4T-O 1 22 NVMe Support Kit for X12 Ultra 220U-TNR without NIC UIO
CBL-KIT-220U-TNR-22  + 2 AOC-SLG4-2E4T-O + 2 AOC-SLG4-4E4T-O 1 22 NVMe Support Kit for X12 Ultra 220U-TNR with NIC UIO
Optional Storage Controller Card + Cable(s) AOC-S3816L-L16iT-O + 2x CBL-SAST-1264F-100 or + 2x CBL-SAST-1264F-100 (For system has 22 NVMe Support Kit with NIC UIO) - Standard LP, 16 internal ports (12Gb/s) Gen-4; HBA
AOC-S3108L-H8iR-16DD + 1x CBL-SAST-1260-100 or + 2x CBL-SAST-1285-100 (For system has 22 NVMe Support Kit with NIC UIO) - Standard LP, 8 internal ports (12Gb/s) Gen-3; RAID 0, 1, 5, 6, 10, 50, 60
AOC-S3908L-H8iR-16DD-O + 1x CBL-SAST-1276F-100 or + 1x CBL-SAST-1264F-100 (For system has 22 NVMe Support Kit with NIC UIO) - Standard LP, 8 internal ports (12Gb/s) Gen-4; RAID 0, 1, 5, 6, 10, 50, 60
AOC-S3916L-H16iR-32DD-O + 1x CBL-SAST-1264F-100, 1x CBL-SAST-1276F-100 or + 2x CBL-SAST-1264F-100 (For system has 22 NVMe Support Kit with NIC UIO) - Standard LP, 16 internal ports (12Gb/s) Gen-4; RAID 0, 1, 5, 6, 10, 50, 60
AOC-S3008L-L8i + 1x CBL-SAST-1260-100 or + 2x CBL-SAST-1285-100 (For system has 22 NVMe Support Kit with NIC UIO) - Standard LP, 8 internal ports (12Gb/s) Gen-3; RAID 0,1,1E
AOC-S3008L-L8E+-O + 1x CBL-SAST-1260-100 or + 2x CBL-SAST-1285-100 (For system has 22 NVMe Support Kit with NIC UIO) - Standard LP, 8 internal ports (12Gb/s) Gen-3; HBA + I2C
AOC-S3008L-L8E + 1x CBL-SAST-1260-100 or + 2x CBL-SAST-1285-100 (For system has 22 NVMe Support Kit with NIC UIO) - Standard LP, 8 internal ports (12Gb/s) Gen-3; HBA
AOC-S3808L-L8iT-O + 1x CBL-SAST-1264F-100 or + 1x CBL-SAST-1264F-100 (For system has 22 NVMe Support Kit with NIC UIO) - Standard LP, 8 internal ports (12Gb/s) Gen-4; HBA
Riser Card RSC-W2-688G4 1
2U LHS WIO Riser card with one PCI-E 4.0 x16andtwoPCI-E4
RSC-W2-66G4 1 2U LHS WIO Riser card with two PCI-E 4.0 x16 slots,HF,RoHS
Software SFT-DCMS-Single 1
DataCenter Management Package (per node license)
Trusted Platform Module Options AOM-TPM-9671V-S-O 1
SPI capable vertical TPM 1.2 provisioned for server,RoHS
AOM-TPM-9670V-S-O 1 SPI capable vertical TPM 2.0 provisioned for server,RoHS
AOM-TPM-9670V-S-FIPS-P 1 AOM-TPM-9670V-S-FIPS TPM 2.0 support TAA and FIPS,RoHS
Ultra Riser Card Options + Rear Window AOC-2UR668G4-O 1
2U Ultra Riser with 2x PCI-E 4.0 x16 and 1x PCI-E 3.0 x8 (internal),,RoHS
AOC-2UR68G4-I4XTS-O + MCP-240-82930-0N 1 2U Ultra Riser with 2-port 10G RJ45 & 2-port 10G SFP+, Intel Carlsville X710-TM4, with 1 PCI-E 4.0 x8 (in x16), 1 PCI-E 4.0 x16 and 1 PCI-E 4.0x8 (internal, in x16),RoHS
AOC-2UR68G4-I2XT-O + MCP-240-82909-0N 1 2U Ultra Riser with 2-port 10G RJ45, Intel Carlsville X710-AT2, 1 PCI-E 4.0 x8 (in x16), 1 PCI-E 4.0 x16 and 1 PCI-E 4.0x8 (internal, in x16),RoHS