SYS-220U-TNR
製品種別 | サーバ |
---|---|
CPUソケット数 | 2 |
CPU | |
筐体サイズ | 2U |
最大GPU数 | |
電源仕様 | リダンダント電源 |
用途/特長 | |
製品説明 | Virtualization HPC Cloud Computing High End Enterprise Server Software Defined Storage Application Tier Service Provider 5G/Telco |
製品仕様
Product SKUs | SYS-220U-TNR | SuperServer SYS-220U-TNR (Black Front & Silver Body) |
---|---|
マザーボード | Super X12DPU-6 |
Processor/Cache | CPU | Dual Socket P+ (LGA-4189) 3rd Gen Intel® Xeon® Scalable processors Support CPU TDP 270W * |
Cores | Up to 40C/80T; Up to 60MB Cache |
Note | *Certain CPUs with high TDP may be supported only under specific conditions. Please contact Supermicro Technical Support for additional information about specialized system optimization |
System Memory | Memory | Memory Capacity: 32 DIMM slots UP to 8TB: 32x 256 GB DRAM UP to 12TB: 16x 512 GB PMem and 16x 256 GB DRAM Memory Type: 3200/2933/2666MHz ECC DDR4 Intel® Optane™ persistent memory 200 series |
Memory Voltage | 1.2 V |
Error Detection | ECC |
On-Board Devices | SATA | SATA3 (6Gbps) via Intel® PCH 621A; RAID 0/1/5/10 support |
NVMe | NVMe (16GT/s); RAID 0/1/5/10 support |
Chipset | Intel® C621A |
Network Connectivity | 2x 10GbE BaseT with Intel® X710-AT2 (optional) OR 2x 10GbE BaseT and 2x 10GbE SFP+ with Intel® X710-TM4 (optional) No NIC option supported |
IPMI | Support for Intelligent Platform Management Interface v.2.0 IPMI 2.0 with virtual media over LAN and KVM-over-LAN support |
BMC | ASPEED AST2600 BMC |
Input / Output | LAN | 1 RJ45 Dedicated BMC LAN port |
USB | 2 USB 3.0 port(s) (2 rear) |
Video | 1 VGA port(s) |
Serial Port | 1 COM Port(s) (1 rear) |
DOM | 2 SuperDOM (Disk on Module) port |
BIOS | BIOS Type | AMI 32MB SPI Flash EEPROM |
マネージメント | Software | Supermicro Out of Band (OOB) License Redfish API IPMI 2.0 Intel® Node Manager KVM with dedicated LAN SUM NMI Watch Dog SuperDoctor® 5 |
Power Configurations | ACPI Power Management Power-on mode for AC power recovery |
システム監視機能 | CPU | 4+1 Phase-switching voltage regulator Monitors for CPU Cores, Chipset Voltages, Memory |
FAN | Fans with tachometer monitoring Pulse Width Modulated (PWM) fan connectors Status monitor for speed control |
Temperature | Monitoring for CPU and chassis environment Thermal Control for fan connectors |
シャーシ | Form Factor | 2U Rackmount |
Model | CSE-219U3TS-R1K62P-T |
外形寸法・重量 | Height | 3.5" (89mm) |
Width | 17.2" (437mm) |
Depth | 27.76" (705.3mm) |
Package | 9.96" (H) x 24.6" (W) x 45.43" (D) |
Weight | Net Weight: 37 lbs (16.8 kg) Gross Weight: 63 lbs (28.6 kg) |
Available Color | Black Front & Silver Body |
フロントパネル | Buttons | Power On/Off UID button |
LEDs | HDD activity LAN1 activity LAN2 acticity Power Fail Power status System information (overheat/UID) |
Expansion Slots | PCI-Express (PCI-E) | Slot 1: PCI-E 4.0 x16 FH, 10.5"L Slot 2: PCI-E 4.0 x8 FH, 10.5"L Slot 3: PCI-E 4.0 x8 Internal LP Slot 4: PCI-E 4.0 x16 LP Slot 5: PCI-E 4.0 x8 FH, 10.5"L Slot 6: PCI-E 4.0 x8 FH, 10.5"L Slot 7: PCI-E 4.0 x8 FH, 10.5"L Slot 8: PCI-E 4.0 x8 FH, 10.5"L |
Note | Optional RSC-W2-66G4 enables PCI-E x16 in slots 5, 7. Slots 6,8 will be disabled. |
Drive Bays / Storage | Hot-swap | 24x 2.5" hot-swap NVMe/SATA/SAS drive bays (22x 2.5" NVMe hybrid) (SAS/NVMe support requires additional parts. Please see the Optional Parts list.) |
冷却機構 | Fans | 4x 8cm heavy duty fans with optimal fan speed control |
Air Shroud | 2 Air Shroud(s) |
Power Supply | Dimension(W x H x L) | 73.5 x 40 x 203 mm |
AC Input | 1000W: 100-127Vac / 50-60Hz 1600W: 200-240Vac / 50-60Hz |
+12V | Max: 83A / Min: 0A (100Vac-127Vac) Max: 133A / Min: 0A (200Vac-240Vac) |
12V SB | Max: 2.1A / Min: 0A |
Output Type | AC-Input |
Certification | |
動作環境 | Environmental Spec. | Operating Temperature: 10°C ~ 35°C (50°F ~ 95°F) Non-operating Temperature: -40°C to 60°C (-40°F to 140°F) Operating Relative Humidity: 8% to 90% (non-condensing) Non-operating Relative Humidity: 5% to 95% (non-condensing) |
パーツ仕様
パーツリスト | |||
---|---|---|---|
型番 | 数量 | 内容 | |
Motherboard / Chassis | MBD-X12DPU-6 CSE-219U3TS-R1K62P-T | 1 1 | Super X12DPU-6 Motherboard 2U Chassis |
Backplane | BPN-NVME4-216N-S24 | 1 |
2U 24-slot all-hybrid direct-attached backplane, support 24x 2.5" NVME Gen4 / SAS / SATA storage devices.,RoHS |
Cable 1 | CBL-CDAT-0674 | 2 |
4 Pin to 4 Pin I2C Cable, 30cm, 26AWG, 4 Wires, Pinout 1-1 |
Cable 2 | CBL-PWEX-0924 | 1 |
2x4,P3.0 to 2x4,P4.2,YL/RED,9.5A,24cm,16AWG,RoHS |
Cable 3 | CBL-PWEX-0925 | 2 |
2x4,P3.0 to 2x4,P4.2,YL/RED,9.5A,55cm,16AWG,RoHS |
Cable 4 | CBL-SAST-1250F-100 | 2 |
Slimline x4 (STR) to Slimline x4 (STR),FFC,INT,50CM,100 |
Cable 5 | CBL-SAST-1270F-100 | 1 |
Slimline x4 (STR) to Slimline x4 (STR),FFC,INT,70CM,100 |
Riser Card | RSC-W2-8888G4 | 1 |
2U LHS WIO Riser card with four PCI-E 4.0 x8 slots,HF,RoHS |
Riser Card | RSC-WR-6 | 1 |
1U RHS WIO Riser card with one PCI-E 4.0 x16 slot,HF,RoHS |
Heatsink / Retention | SNK-P0078P | 2 |
2U Passive CPU Heat Sink for X12 Generation Intel Whitley and Cedar Island Platforms |
*Power Supply | PWS-1K62A-1R | 2 |
AC-DC 1600W, Titanium Level, Redundancy, 1U, DC Output: +12V and +12Vs, 203 x 73.5 x 40 mm, AC Input: 90 - 264 VAC/47-63Hz, PMBus 1.2 with DSP controller,HF,RoHS/REACH |
*Cable 6 | CBL-0088L | 4 |
10.5" 4PIN FAN POWER CORD FOR 743X-645,PBF |
*Cable 7 | CBL-0160L | 2 |
US POWER CORD 16AWG, PB FREE |
*FAN 1 | FAN-0206L4 | 4 |
80x80x38 mm, 13.5K RPM, Middle Cooling Fan for 2U and above Servers |
*FAN 2 | FAN-0209L4 | 4 |
80x80x38 mm, 13.5K RPM, Middle Cooling Fan for 2U and above |
*Drive Tray(s) | MCP-220-00047-0B | 2 4 |
Black gen 3rd hot-swap 2.5inch HDD tray |
*Rail Set | MCP-290-00057-0N | 1 |
Rail set, quick/quick, default for 4U 17.2"; W |
*Rail Set | MCP-290-00060-0N | 1 |
Threaded rail adapter default for round hole rack |
*Air Shroud | MCP-310-81905-0B | 1 |
Plastic air shroud for SC819U, 119U, 829U, 219U (PWS),RoHS/REACH |
*Rail Set | MCP-290-00115-0N | 1 |
Inner rail, quick-release type |
*Rail Set | MCP-290-00117-0N | 1 |
Outer rail, quick-release type |
オプションパーツリスト | |||
型番 | 数量 | 内容 | |
2 Rear 2.5" Hot-swap SATA Drive Bays (Complete System Only) | MCP-240-82922-0N-OEM | 1 |
Rear 2x 2.5" HDDs riser bracket kit for SC829U/219U, tool-less |
Add-on card for M.2 support | AOC-SLG3-2H8M2-O | - | 2x Hybrid NVMe/SATA M.2 RAID Carrier, Standard LP,RoHS |
CacheVaults | BTR-CVPM05 + BKT-BBU-BRACKET-05 | - | CacheVault for Broadcom 3908/3916 with Supercap |
BTR-CV3108-U1 | - | CacheVault for Broadcom 3108 with Supercap mounting for 2U Ultra | |
Drive Tray | MCP-220-00167-0B | 1 ~ 22 | 2.5 drive tray, Orange tab (for hotswap NVMe drive) |
Global Services & Support | OSNBD3/2/1 | - | 3/2/1-year onsite NBD service |
OS4HR3/2/1 | - | 3/2/1-year onsite 24x7x4 service | |
Intel® VROC RAID Key Options | AOC-VROCPREMOD | 1 |
Intel VROC Premium, RAID 0, 1, 5, 10 |
AOC-VROCSTNMOD | 1 | Intel VROC Standard, RAID 0, 1, 10 | |
AOC-VROCINTMOD | 1 | Intel VROC, RAID 0, 1, 5, 10 (Intel SSD Only) | |
NVMe Support Kit | CBL-KIT-220U-TNR-8 | 1 |
8 NVMe Support Kit for X12 Ultra SYS-220U-TNR |
CBL-KIT-220U-TNR-22N + 3 AOC-SLG4-4E4T-O | 1 | 22 NVMe Support Kit for X12 Ultra 220U-TNR without NIC UIO | |
CBL-KIT-220U-TNR-22 + 2 AOC-SLG4-2E4T-O + 2 AOC-SLG4-4E4T-O | 1 | 22 NVMe Support Kit for X12 Ultra 220U-TNR with NIC UIO | |
Optional Storage Controller Card + Cable(s) | AOC-S3816L-L16iT-O + 2x CBL-SAST-1264F-100 or + 2x CBL-SAST-1264F-100 (For system has 22 NVMe Support Kit with NIC UIO) | - | Standard LP, 16 internal ports (12Gb/s) Gen-4; HBA |
AOC-S3108L-H8iR-16DD + 1x CBL-SAST-1260-100 or + 2x CBL-SAST-1285-100 (For system has 22 NVMe Support Kit with NIC UIO) | - | Standard LP, 8 internal ports (12Gb/s) Gen-3; RAID 0, 1, 5, 6, 10, 50, 60 | |
AOC-S3908L-H8iR-16DD-O + 1x CBL-SAST-1276F-100 or + 1x CBL-SAST-1264F-100 (For system has 22 NVMe Support Kit with NIC UIO) | - | Standard LP, 8 internal ports (12Gb/s) Gen-4; RAID 0, 1, 5, 6, 10, 50, 60 | |
AOC-S3916L-H16iR-32DD-O + 1x CBL-SAST-1264F-100, 1x CBL-SAST-1276F-100 or + 2x CBL-SAST-1264F-100 (For system has 22 NVMe Support Kit with NIC UIO) | - | Standard LP, 16 internal ports (12Gb/s) Gen-4; RAID 0, 1, 5, 6, 10, 50, 60 | |
AOC-S3008L-L8i + 1x CBL-SAST-1260-100 or + 2x CBL-SAST-1285-100 (For system has 22 NVMe Support Kit with NIC UIO) | - | Standard LP, 8 internal ports (12Gb/s) Gen-3; RAID 0,1,1E | |
AOC-S3008L-L8E+-O + 1x CBL-SAST-1260-100 or + 2x CBL-SAST-1285-100 (For system has 22 NVMe Support Kit with NIC UIO) | - | Standard LP, 8 internal ports (12Gb/s) Gen-3; HBA + I2C | |
AOC-S3008L-L8E + 1x CBL-SAST-1260-100 or + 2x CBL-SAST-1285-100 (For system has 22 NVMe Support Kit with NIC UIO) | - | Standard LP, 8 internal ports (12Gb/s) Gen-3; HBA | |
AOC-S3808L-L8iT-O + 1x CBL-SAST-1264F-100 or + 1x CBL-SAST-1264F-100 (For system has 22 NVMe Support Kit with NIC UIO) | - | Standard LP, 8 internal ports (12Gb/s) Gen-4; HBA | |
Riser Card | RSC-W2-688G4 | 1 |
2U LHS WIO Riser card with one PCI-E 4.0 x16andtwoPCI-E4 |
RSC-W2-66G4 | 1 | 2U LHS WIO Riser card with two PCI-E 4.0 x16 slots,HF,RoHS | |
Software | SFT-DCMS-Single | 1 |
DataCenter Management Package (per node license) |
Trusted Platform Module Options | AOM-TPM-9671V-S-O | 1 |
SPI capable vertical TPM 1.2 provisioned for server,RoHS |
AOM-TPM-9670V-S-O | 1 | SPI capable vertical TPM 2.0 provisioned for server,RoHS | |
AOM-TPM-9670V-S-FIPS-P | 1 | AOM-TPM-9670V-S-FIPS TPM 2.0 support TAA and FIPS,RoHS | |
Ultra Riser Card Options + Rear Window | AOC-2UR668G4-O | 1 |
2U Ultra Riser with 2x PCI-E 4.0 x16 and 1x PCI-E 3.0 x8 (internal),,RoHS |
AOC-2UR68G4-I4XTS-O + MCP-240-82930-0N | 1 | 2U Ultra Riser with 2-port 10G RJ45 & 2-port 10G SFP+, Intel Carlsville X710-TM4, with 1 PCI-E 4.0 x8 (in x16), 1 PCI-E 4.0 x16 and 1 PCI-E 4.0x8 (internal, in x16),RoHS | |
AOC-2UR68G4-I2XT-O + MCP-240-82909-0N | 1 | 2U Ultra Riser with 2-port 10G RJ45, Intel Carlsville X710-AT2, 1 PCI-E 4.0 x8 (in x16), 1 PCI-E 4.0 x16 and 1 PCI-E 4.0x8 (internal, in x16),RoHS |