製品情報

SYS-620U-TNR

製品種別 サーバ
CPUソケット数 2
CPU  
筐体サイズ 2U
最大GPU数
電源仕様 リダンダント電源
用途/特長   
製品説明 Virtualization
HPC
Cloud Computing
High End Enterprise Server
Software Defined Storage
Application Tier Service Provider
5G/Telco

第3世代 Intel Xeon Scalable プロセッサーについて


Supermicroについて


製品仕様

Product SKUs
SYS-620U-TNR SuperServer SYS-620U-TNR (Black Front & Silver Body)
マザーボード
Super X12DPU-6
Processor/Cache
CPU Dual Socket P+ (LGA-4189)
3rd Gen Intel® Xeon® Scalable processors
3 UPI up to 11.2GT/s
Support CPU TDP 270W *
Cores Up to 40C/80T; Up to 60MB Cache
Note *Certain CPUs with high TDP may be supported only under specific conditions. Please contact Supermicro Technical Support for additional information about specialized system optimization
System Memory
Memory Memory Capacity: 32 DIMM slots
UP to 8TB: 32x 256 GB DRAM
UP to 12TB: 16x 512 GB PMem and 16x 256 GB DRAM
Memory Type: 3200/2933/2666MHz ECC DDR4 RDIMM;LRDIMM
Intel® Optane™ persistent memory 200 series
Memory Voltage 1.2 V
Error Detection ECC
On-Board Devices
SATA SATA3 (6Gbps) via Intel® PCH 621A; RAID 0/1/5/10 support
NVMe NVMe (16GT/s); RAID 0/1/5/10 support
Chipset Intel® C621A
Network Connectivity 2x 10GbE BaseT with Intel® X710-AT2 (optional) OR
2x 10GbE BaseT and 2x 10GbE SFP+ with Intel® X710-TM4 (optional)
No NIC option supported
IPMI Support for Intelligent Platform Management Interface v.2.0
IPMI 2.0 with virtual media over LAN and KVM-over-LAN support
BMC ASPEED AST2600 BMC
Input / Output
LAN 1 RJ45 Dedicated BMC LAN port
USB 2 USB 3 port(s) (2 rear)
Video 1 VGA port(s)
Serial Port 1 COM Port(s) (1 rear)
DOM 2 SuperDOM (Disk on Module) port
BIOS
BIOS Type AMI 32MB SPI Flash EEPROM
マネージメント
Software Redfish API
IPMI 2.0
SSM
Intel® Node Manager
SPM
KVM with dedicated LAN
SUM
NMI
Watch Dog
SuperDoctor® 5
Power Configurations ACPI Power Management
Power-on mode for AC power recovery
システム監視機能
CPU 4+1 Phase-switching voltage regulator
Monitors for CPU Cores, Chipset Voltages, Memory
FAN Fans with tachometer monitoring
Pulse Width Modulated (PWM) fan connectors
Status monitor for speed control
Temperature Monitoring for CPU and chassis environment
Thermal Control for fan connectors
シャーシ
Form Factor 2U Rackmount
Model CSE-829U3TS-R1K22P-T
外形寸法・重量
Height 3.5" (89mm)
Width 17.2" (437mm)
Depth 28.46" (723mm)
Package 10.07" (H) x 23.81" (W) x 37.28" (D)
Weight Net Weight: 35.5 lbs (16.2 kg)
Gross Weight: 57.5 lbs (26.2 kg)
Available Color Black Front & Silver Body
フロントパネル
Buttons Power On/Off 
UID button
LEDs HDD activity
LAN1 activity
LAN2 acticity
Power Fail
Power status
System information (overheat/UID) 
Expansion Slots
PCI-Express (PCI-E) Slot 1: PCI-E 4.0 x16 FH, 10.5"L
Slot 2: PCI-E 4.0 x8 FH, 10.5"L
Slot 3: PCI-E 4.0 x8 Internal LP
Slot 4: PCI-E 4.0 x16 LP
Slot 5: PCI-E 4.0 x8 FH, 10.5"L
Slot 6: PCI-E 4.0 x8 FH, 10.5"L
Slot 7: PCI-E 4.0 x8 FH, 10.5"L
Slot 8: PCI-E 4.0 x8 FH, 10.5"L
Note Optional RSC-W2-66G4 enables PCI-E x16 in slots 5, 7. Slots 6,8 will be disabled.
Drive Bays / Storage
Hot-swap 12x 3.5" hot-swap NVMe/SATA/SAS drive bays (12x 2.5" NVMe hybrid) (SAS/NVMe support requires additional parts. Please see the Optional Parts list.)
冷却機構
Fans 4x 8cm heavy duty fans with optimal fan speed control
Air Shroud 2 Air Shroud(s)
Power Supply
Dimension(W x H x L) 73.5 x 40 x 203 mm
AC Input 800W: 100-127Vac / 50-60Hz
1200W: 200-240Vac / 50-60Hz
1200W: 200-240Vdc (For CCC Only)
+12V Max: 66.7A / Min: 0A (100Vac-127Vac)
Max: 100A / Min: 0A (200Vac-240Vac)
Max: 100A / Min: 0A (200Vdc-240Vdc) (For CCC Only)
12V SB Max: 2.1A / Min: 0A
Output Type AC-Input
Certification
動作環境
Environmental Spec. Operating Temperature:    10°C ~ 35°C (50°F ~ 95°F)
Non-operating Temperature:    -40°C to 60°C (-40°F to 140°F)
Operating Relative Humidity:    8% to 90% (non-condensing)
Non-operating Relative Humidity:    5% to 95% (non-condensing)

パーツ仕様

パーツリスト
型番 数量 内容
Motherboard / Chassis MBD-X12DPU-6 CSE-829U3TS-R1K22P-T 1
1
Super X12DPU-6 Motherboard 2U Chassis
Backplane BPN-SAS3-LA26A-N12 1 2U 12-Slot LFF Backplane Supports 12 x SAS3/SATA3/NVMe4 Storage Devices with 1x(2x4) + 4x(1x4) power connectors, co-lay with BPN-SAS3-LA26A-N12,HF,RoHS
Cable 1 CBL-PWEX-0923 1 2x4,P3.0 to 2x4,RA,P4.2,YL,9.5A,38cm,16AWG,RoHS
Cable 2 CBL-SAST-1241F-100 1 Slimline x4 (STR) to Slimline x4 (STR),FFC,INT,41CM,100
Cable 3 CBL-SAST-1250F-100 2 Slimline x4 (STR) to Slimline x4 (STR),FFC,INT,50CM,100
Riser Card RSC-W2-8888G4 1 2U LHS WIO Riser card with four PCI-E 4.0 x8 slots,HF,RoHS
Riser Card RSC-WR-6 1 1U RHS WIO Riser card with one PCI-E 4.0 x16 slot,HF,RoHS
Heatsink / Retention SNK-P0078P 2 2U Passive CPU Heat Sink for X12 Generation Intel Whitley and Cedar Island Platforms
*Power Supply PWS-1K22A-1R 2 1U 1200W/800W Titanium Redundant Power Supply CRPS 73.5x203x40mm,RoHS/REACH
オプションパーツリスト
型番 数量 内容
AOC-2UR668G4-O AOC-2UR668G4-O 1 2U Ultra Riser with 2x PCI-E 4.0 x16 and 1x PCI-E 3.0 x8 (internal),,RoHS
AOC-2UR68G4-I2XT-O + MCP-240-82909-0N AOC-2UR68G4-I2XT-O + MCP-240-82909-0N 1 2U Ultra Riser with 2-port 10G RJ45, Intel Carlsville X710-AT2, 1 PCI-E 4.0 x8 (in x16), 1 PCI-E 4.0 x16 and 1 PCI-E 4.0x8 (internal, in x16),RoHS
AOC-2UR68G4-I4XTS-O + MCP-240-82930-0N AOC-2UR68G4-I4XTS-O + MCP-240-82930-0N 1 2U Ultra Riser with 2-port 10G RJ45 & 2-port 10G SFP+, Intel Carlsville X710-TM4, with 1 PCI-E 4.0 x8 (in x16), 1 PCI-E 4.0 x16 and 1 PCI-E 4.0x8 (internal, in x16),RoHS
AOC-S3108L-H8iR-16DD AOC-S3108L-H8iR-16DD - Standard LP, 8 internal ports (12Gb/s) Gen-3, 16HDD; RAID 0, 1, 5, 6, 10, 50, 60
AOC-S3808L-L8iT-P AOC-S3808L-L8iT-P - Standard LP, 8 internal ports (12Gb/s) Gen-4 ; HBA
AOC-S3816L-L16iT-P AOC-S3816L-L16iT-P - Standard LP, 16 internal ports (12Gb/s) Gen-4; HBA
AOC-S3908L-H8iR-16DD-P AOC-S3908L-H8iR-16DD-P - Standard LP, 8 internal ports (12Gb/s) Gen-4, 16HDD; RAID 0, 1, 5, 6, 10, 50, 60
AOC-S3916L-H16iR-32DD-P AOC-S3916L-H16iR-32DD-P - Standard LP, 16 internal ports (12Gb/s) Gen-4, 32HDD; RAID 0, 1, 5, 6, 10, 50, 60
AOC-SLG3-2H8M2-P AOC-SLG3-2H8M2-P - 2x Hybrid NVMe/SATA M.2 RAID Carrier, Standard LP,RoHS
AOC-VROCINTMOD AOC-VROCINTMOD 1 Intel VROC, RAID 0, 1, 5, 10 (Intel SSD Only)
AOC-VROCPREMOD AOC-VROCPREMOD 1 Intel VROC Premium, RAID 0, 1, 5, 10
AOC-VROCSTNMOD AOC-VROCSTNMOD 1 Intel VROC Standard, RAID 0, 1, 10
AOM-TPM-9670V-S-FIPS-P   AOM-TPM-9670V-S-FIPS-P   1 AOM-TPM-9670V-S-FIPS TPM 2.0 support TAA and FIPS,RoHS
AOM-TPM-9670V-S-P   AOM-TPM-9670V-S-P   1 SPI capable vertical TPM 2.0 provisioned for server,RoHS
AOM-TPM-9671V-S-P  AOM-TPM-9671V-S-P  1 SPI capable vertical TPM 1.2 provisioned for server,RoHS
BTR-CV3108-U1 BTR-CV3108-U1 - CacheVault for Broadcom 3108 with Supercap mounting for 2U Ultra
BTR-CVPM05 + BKT-BBU-BRACKET-05 BTR-CVPM05 + BKT-BBU-BRACKET-05 - CacheVault for Broadcom 3908/3916 with Supercap
CBL-KIT-620U-TNR-12N +1 AOC-SLG4-2E4T-P CBL-KIT-620U-TNR-12N +1 AOC-SLG4-2E4T-P 1 12 NVMe Kit for X12 Ultra 620U-TNR without NIC UIO
CBL-KIT-620U-TNR-12 + 1 AOC-SLG4-2E4T-P CBL-KIT-620U-TNR-12 + 1 AOC-SLG4-2E4T-P 1 12 NVMe Kit for X12 Ultra 620U-TNR with NIC UIO
MCP-220-00138-0B MCP-220-00138-0B 1 ~ 12 Black gen-5.5 tool-less NVMe 3.5-to-2.5 drive tray, Orange tab
MCP-240-82922-0N-OEM MCP-240-82922-0N-OEM 1 Rear 2x 2.5" HDDs riser bracket kit for SC829U/219U, tool-less
OS4HR3/2/1 OS4HR3/2/1 - 3/2/1-year onsite 24x7x4 service
OSNBD3/2/1 OSNBD3/2/1 - 3/2/1-year onsite NBD service
SFT-DCMS-Single SFT-DCMS-Single 1 DataCenter Management Package (per node license)