SYS-610C-TR
製品種別 | サーバ |
---|---|
CPUソケット数 | 2 |
CPU | |
筐体サイズ | 1U |
最大GPU数 | |
電源仕様 | リダンダント電源 |
用途/特長 | |
製品説明 |
製品仕様
Product SKUs | SYS-610C-TR | SuperServer SYS-610C-TR (Black front & sliver body) |
---|---|
マザーボード | Super X12DDW-A6 |
Processor/Cache | CPU | Dual Socket P+ (LGA-4189) 3rd Gen Intel® Xeon® Scalable processors 3 UPI up to 11.2GT/s Support CPU TDP 270W CPUs with TDP higher than 205W may have support conditions due to power and thermal limitations. |
Cores | Up to 40C/80T |
System Memory | Memory | Memory Capacity: 16 DIMM slots UP to 4TB: 16x 256 GB DRAM UP to 6TB: 8x 256 GB DRAM and 8x 512 GB PMem Memory Type: 3200/2933/2666MHz ECC DDR4 RDIMM;LRDIMM Intel® Optane™ persistent memory 200 series |
Memory Voltage | 1.2 V |
Error Detection | ECC |
On-Board Devices | SATA | SATA3 (6Gbps); RAID 0/1/5/10 support |
Chipset | Intel® C621A |
Network Connectivity | Via Slim-AIOM |
IPMI | Support for Intelligent Platform Management Interface v.2.0 IPMI 2.0 with virtual media over LAN and KVM-over-LAN support |
Input / Output | SATA | 1 SuperDOM port(s) |
LAN | 1 Dedicated IPMI LAN port |
USB | 2 USB 3 port(s) (2 Rear_USB) |
Video | 1 VGA port(s) |
BIOS | BIOS Type | AMI 32MB SPI FLASH ROM |
マネージメント | Software | SCC Redfish API IPMI 2.0 SSM Intel® Node Manager SPM KVM with dedicated LAN SUM NMI Watch Dog SuperDoctor® 5 |
Power Configurations | ACPI/APM Power Management |
システム監視機能 | CPU | 4+1 Phase-switching voltage regulator Monitors for CPU Cores, Chipset Voltages, Memory. |
FAN | Fans with tachometer monitorin Pulse Width Modulated (PWM) fan connectors Status monitor for speed control |
Temperature | Monitoring for CPU and chassis environment Thermal Control for fan connectors |
シャーシ | Form Factor | 1U Rackmount |
Model | CSE-LA15TQC-R860AW |
外形寸法・重量 | Height | 1.7" (43mm) |
Width | 17.2" (437mm) |
Depth | 25.6" (650mm) |
Package | 7.8" (H) x 23.8" (W) x 34.6" (D) |
Weight | Net Weight: 25.5 lbs (11.6 kg) Gross Weight: 41.5 lbs (18.8 kg) |
Available Color | Black front & sliver body |
フロントパネル | Buttons | Power On/Off button UID button |
LEDs | HDD activity LED Network activity LEDs Power status LED Universal Information (UID) LED |
Expansion Slots | PCI-Express (PCI-E) | Slot 1: PCI-E 4.0 x16 FHHL Slot 2: PCI-E 4.0 x16 FHHL |
Drive Bays / Storage | Hot-swap | 4x 3.5" hot-swap SATA/SAS drive bays |
M.2 | 2 M.2 NVMe M-Key, 2280 |
Peripheral Bays | 2x 2.5" drive bays (optional) |
冷却機構 | Fans | 6x 4cm heavy duty fans with optimal fan speed control |
Air Shroud | 2 Air Shroud(s) |
Power Supply | Dimension(W x H x L) | 54.5 x 40.25 x 320 mm |
Output Type | Gold Finger |
Certification | |
動作環境 | Environmental Spec. | Operating Temperature: 10°C ~ 35°C (50°F ~ 95°F) Non-operating Temperature: -40°C to 60°C (-40°F to 140°F) Operating Relative Humidity: 8% to 90% (non-condensing) Non-operating Relative Humidity: 5% to 95% (non-condensing) |
パーツ仕様
パーツリスト | |||
---|---|---|---|
型番 | 数量 | 内容 | |
Motherboard / Chassis | MBD-X12DDW-A6 CSE-LA15TQC-R860AW | 1 1 | Super X12DDW-A6 Motherboard 1U Chassis |
Backplane | BPN-SAS3-815TQ | 1 |
1U 4-Port 12Gbps Backplane Support 4x3.5 |
Cable 1 | CBL-SAST-1295LP-100 | 1 |
SlimlineLP x4 (STR) to 4x SATA (STR),75/75/90/90/75CM,10 |
FAN 1 | FAN-0101L4 | 2 |
40x56,4 Pin PWM,Primary for SC809,111, Sec.for SC816,819,808 |
Parts | MCP-150-00015-0B | 6 |
Rubber pad, 3.0mm H, 10x10mm |
Air Shroud | MCP-310-00105-0B | 2 |
Mylar Air Shroud for LA15-AW,LB13-AW,LB16-AW + X12DDW |
Manual | MNL-2343-QRG | 1 |
610C-TR Quick Reference Guide |
Riser Card | RSC-D-6G4 | 1 |
1U LHS DCO Riser card with one PCI-E 4.0 x16 slot,HF,RoHS |
Riser Card | RSC-DR-6G4 | 1 |
1U RHS DCO Riser card with one PCI-E 4.0 x16 slot,HF,RoHS |
Heatsink / Retention | SNK-P0077P | 2 |
1U Passive CPU Heat Sink for X12 Generation Intel Whitley and Cedar Island Platforms |
*Power Supply | PWS-860P-1R2 | 2 |
1U 860W, Redundant power supply, 54.5mm width, Platinum with |
*Power Distributor | PDB-PT116-SL8824 | 1 |
Based on PDB-PT116-L8824 to optimize 24Pin etc cable lengths |
*Cable 2 | CBL-CDAT-0680-55 | 1 |
[NR]FRNT CNTL,FLAT,IDC 2x10,PH1.27 TO 2x10,PH1.27,55CM,28AWG |
*Cable 3 | CBL-PWCD-0160-IS | 2 |
PWCD,US,NEMA5-15P TO IEC60320 C13,6FT,16AWG,RoHS/REACH |
*FAN 2 | FAN-0101L4 | 4 |
40x56,4 Pin PWM,Primary for SC809,111, Sec.for SC816,819,808 |
*Front Panel | FPB-FP815U | 1 |
815 UIO front control board (U) |
*Parts | MCP-160-00028-0B | 1 |
Mylar Cable Channel for Cloud-DC, X12 DDW |
*Drive Tray(s) | MCP-220-00184-0B | 4 |
Black gen-9 tool-less cost-effective 3.5 |
*Rear Window | MCP-240-00173-0N | 1 |
1U X12 AWIO Rear window for LA15,LB16,LB13 Redundant PWS |
*Power Supply | MCP-250-81502-0N | 1 |
SC815 Redundant Power Distributor Cover |
*Rail Set | MCP-290-00054-0N | 1set | Rail set, quick/quick, optional for 1U 17.2 |
*Fan Holder | MCP-320-00056-0B | 2 4 |
40X56 rubber fan pin for SC819U, SC119U,RoHS/REACH |
*Fan Holder | MCP-320-00066-0B | 1 |
Fan holder with cable channel, 40X56mm fan, for LA15,LB16,LB13 |
*Parts | MCP-320-00067-0B | 1 |
Chassis base Air Foam block set (L+R) for Cloud-DC |
*Fan Holder | MCP-340-00035-0B | 2 |
Dummy fan 40x56mm for 40x56 counter-rotating fan (cost-effective) |
オプションパーツリスト | |||
型番 | 数量 | 内容 | |
3108 CacheVault | BTR-CV3108-1U1 | 1 |
CacheVault for Broadcom 3108 with SuperCap mounting in 1U 40x56 fan tray |
BTR-TFM8G-LSICVM02 | 1 | CacheVault for Broadcom 3108 | |
BKT-BBU-BRACKET-05 | 1 | SuperCap mounting bracket for PCI-E location | |
MCP-240-00127-0N | 1 | SuperCap mounting bracket for 2.5" HDD location | |
3108 RAID Card | CBL-SAST-0699 | 1 |
Mini SAS HD-4 SATA,12G,75/75/90/90CM,75CM SB |
AOC-S3108L-H8IR-16DD | 1 | Standard LP, 8 internal ports (12Gb/s) Gen-3, 16HDD; RAID 0, 1, 5, 6, 10, 50, 60; | |
3808 HBA Card | CBL-SAST-1275A-100 | 1 |
Slimline x8 (STR) to 4x SATA, 75/75/90/90CM,75CM SB |
AOC-S3808L-L8IT | 1 | Standard LP, 8 internal ports (12Gb/s) Gen-4, 16HDD; HBA; | |
3908 RAID Card | AOC-S3908L-H8IR-16DD | 1 |
Standard LP, 8 internal ports (12Gb/s) Gen-3, 122HDD; RAID 0, 1, 5, 6, 10, 50, 60; |
CBL-SAST-1275A-100 | 1 | Slimline x8 (STR) to 4x SATA, 75/75/90/90CM,75CM SB | |
3908/3916 CacheVault | BKT-BBU-BRACKET-05 | 1 |
SuperCap mounting bracket for PCI-E location |
MCP-240-00127-0N | 1 | SuperCap mounting bracket for 2.5" HDD location | |
BTR-CVPM05 | 1 | CacheVault for Broadcom 3908/3916 | |
Add-on card for additional M.2 | AOC-SLG3-2H8M2 | - | Low Profile PCI-E x8 add-on card supports 2 PCI-E 3.0 x4 M-Key M.2 NVMe/SATA Modules; RAID 0,1 |
AOC-SLG3-2M2 | - | Low Profile PCI-E x8 add-on card supports 2 PCI-E 3.0 x4 M-Key M.2 NVMe Modules | |
AIOM Network Card(s) | AOC-AG-i4M | - | OCP 3.0 AIOM NIC, 4x 1GbE RJ45, PCI-E 2.1 x4, Intel® i350-AM4 |
AOC-AH25G-m2S2TM | - | OCP 3.0 AIOM NIC, 2x 25GbE SFP28 & 2x 10GbE RJ45, PCI-E x8/x4, Mellanox® CX4 Lx EN & Intel® X550-AT2 | |
AOC-A100G-b2CM | - | OCP 3.0 AIOM NIC, 2x 100GbE QSFP28, PCI-E 4.0 x16, Broadcom® BCM57508 | |
AOC-ATG-i2SM | - | OCP 3.0 AIOM NIC, 2x 10GbE SFP+, PCI-E 3.0 x8, Intel® X710-BM2 | |
AOC-A25G-b2SM | - | OCP 3.0 AIOM NIC, 2x 25GbE SFP28, PCI-E x8, Broadcom® BCM57414 | |
AOC-ATG-i2TM | - | OCP 3.0 AIOM NIC, 2x 10GbE RJ45, PCI-E 3.0 x4, Intel® X550-AT2 | |
AOC-AG-i2M | - | OCP 3.0 AIOM NIC, 2x 1GbE RJ45, PCI-E 2.1 x4, Intel® i350-AM2 | |
AOC-AG-i4SM | - | OCP 3.0 AIOM NIC, 4x 1GbE SFP, PCI-E 2.1 x4, Intel® i350-AM4 | |
AOC-ATGC-i2TM | - | OCP 3.0 AIOM NIC, 2x 10GbE RJ45, PCI-E 3.0 x4, Intel X710-AT2 | |
AOC-A100G-m2CM | - | OCP 3.0 AIOM NIC, 2x 100GbE QSFP28, PCI-E 4.0 x16, Mellanox® CX-6 DX | |
AOC-ATG-i2T2SM | - | OCP 3.0 AIOM NIC, 4x 10GbE RJ45 & SFP+, PCI-E x8, Intel® X710-TM4 | |
AOC-A25G-m2SM | - | OCP 3.0 AIOM NIC, 2x 25GbE SFP28, PCI-E x8, Mellanox® CX-6 LX | |
AOC-ATG-i4SM | - | OCP 3.0 AIOM NIC, 4x 10GbE SFP+, PCI-E 3.0 x8, Intel® XL710-BM1 | |
Cable Management Arm | MCP-290-00152-0N | 1 |
1U Supermicro Cable Management Arm 2nd Gen |
Fan Upgrade | FAN-0163L4 | 6 |
40x40x56 mm, 23.3K-20.3K RPM, Counter-rotating Fan |
Fixed 2.5" Drive Kit | CBL-0289L | 1 |
30CM SATA Power Cable (1 TO 2 SATA) |
MCP-220-81511-0N | 2 | FDD-size tray support for 1x 2.5" 7mm drive | |
CBL-SAST-0624 | 2 | 70cm SATA Cable S-S | |
Intel VROC Key | AOC-VROCPREMOD | 1 |
Intel VROC Premium, RAID 0, 1, 5, 10 |
AOC-VROCINTMOD | 1 | Intel VROC, RAID 0, 1, 5, 10 (Intel SSD Only) | |
AOC-VROCSTNMOD | 1 | Intel VROC Standard, RAID 0, 1, 10 | |
Software | SFT-DCMS-Single | 1 |
DataCenter Management Package (per node license) |
TPM security module | AOM-TPM-9670V-S-FIPS | 1 |
SPI capable TPM 2.0 with Infineon 9670 controller w/ FIPS; vertical form factor |
AOM-TPM-9671V | 1 | SPI capable TPM 1.2 with Infineon 9670 controller; vertical form factor | |
AOM-TPM-9670V | 1 | SPI capable TPM 2.0 with Infineon 9670 controller; vertical form factor |