SYS-6029UZ-TR4_
製品種別 | サーバ |
---|---|
CPUソケット数 | |
CPU | |
筐体サイズ | 2U |
最大GPU数 | |
電源仕様 | リダンダント電源 |
用途/特長 | |
製品説明 |
製品仕様
Product SKUs | SYS-6029UZ-TR4+ | SuperServer 6029UZ-TR4+ (Black) |
---|---|
プロセッサ/キャッシュ | CPU | Dual Socket P (LGA 3647) 2nd Gen. Intel® Xeon® Scalable Processors (Cascade Lake/Skylake)‡,3 UPI up to 10.4GT/s Support CPU TDP 70-205W |
Cores | Up to 28 Cores |
Note | ‡ BIOS version 3.0a or above is required to support 2nd Gen. Intel® Xeon® Scalable processors |
メモリ | Memory Capacity | 24 DIMM slots Up to 6TB 3DS ECC DDR4-2933MHz† RDIMM/LRDIMM Supports Intel® Optane™ DCPMM†† |
Memory Type | 2933†/2666/2400/2133MHz ECC DDR4 RDIMM/LRDIMM |
Note | † 2933MHz in two DIMMs per channel can be achieved by using memory purchased from Supermicro†† Cascade Lake only. Contact your Supermicro sales rep for more info. |
オンボードデバイス | Chipset | Intel® C621 chipset |
SATA | SATA3 (6Gbps); RAID 0, 1, 5, 10 |
Network Connectivity | 4x 1GbE LAN ports via Intelî i350 (AOC-2UR68-i4G) |
IPMI | Support for Intelligent Platform Management Interface v.2.0 IPMI 2.0 with virtual media over LAN and KVM-over-LAN support |
Graphics | ASPEED AST2500 BMC |
標準インターフェース | SATA | 10 SATA3 (6Gbps) ports |
LAN | 4 GbE ports 1 RJ45 Dedicated IPMI LAN port |
USB | 3 USB 3.0 ports (2 rear, 1 Type A) |
Video | 2 VGA ports (1 rear, 1 onboard) |
Serial Port | 1 Serial header |
DOM | 2 SuperDOM (Disk on Module) ports |
BIOS | BIOS Type | AMI 32Mb SPI Flash ROM |
マネージメント | Software | Intel® Node Manager Redfish API IPMI 2.0 KVM with dedicated LAN NMI SSM, SPM, SUM SuperDoctor® 5 |
Power Configurations | ACPI Power Management |
システム監視機能 | CPU | Monitors for CPU Cores, Chipset Voltages, Memory. 4+1 Phase-switching voltage regulator |
FAN | Fans with tachometer monitoring Status monitor for speed control Pulse Width Modulated (PWM) fan connectors |
Temperature | Monitoring for CPU and chassis environment Thermal Control for fan connectors |
シャーシ | Form Factor | 2U Rackmount |
Model | CSE-219U2AC4-R1K62-T |
外形寸法・重量 | Height | 3.5" (89mm) |
Width | 17.2" (437mm) |
Depth | 28.46" (723mm) |
Weight | Net Weight: 36 lbs (16.4 kg) Gross Weight: 72 lbs (32.7 kg) |
Available Color | Black |
フロントパネル | Buttons | Power On/Off button System UID button |
LEDs | Power LED Hard drive activity LED Network activity LEDs UID LED |
拡張スロット | PCI-Express | 1 PCI-E 3.0 x16 slot (FH, 10.5"L) 5 PCI-E 3.0 x8 slot (FH, 10.5"L) 1 PCI-E 3.0 x8 slot (LP) 1 PCI-E 3.0 x8 slot (internal LP) |
ドライブベイ・ストレージ | Hot-swap | 12 Hot-swap 3.5" drive baysOptional 8 SAS3 + 4 SAS3/NVMe 2 Rear Hot-swap 2.5" drive bays |
M.2 | 1 M.2 PCI-E 3.0 x4 M-Key NVMe or 1 M.2 M-Key SATA3 (2240/2260/2280/22110) via optional riser card (see optional parts list) 2 M.2 PCI-E 3.0 x4 M-Key NVMe (2260/2280/22110) via optional add-on card AOC-SLG3-2M2 |
冷却機構 | Fans | 4 Heavy duty 8cm fans |
電源 | Total Output Power | 1600W/1000W |
Dimension(W x H x L) | 73.5 x 40 x 203 mm |
Input | 100-127Vac / 13 - 9A / 50-60Hz 200-240Vac / 10 - 8A / 50-60Hz |
+12V | Max: 83.3A / Min: 0A (100-127Vac) Max: 133A / Min: 0A (200-240Vac) |
12Vsb | Max: 2.1A / Min: 0A |
Output Type | 25 Pairs Gold Finger Connector |
Certification | Titanium Level [ Test Report ] |
動作環境 | RoHS | RoHS Compliant |
Environmental Spec. | Operating Temperature: 10°C ~ 35°C (50°F ~ 95°F) Non-operating Temperature: -40°C to 60°C (-40°F to 140°F) Operating Relative Humidity: 8% to 90% (non-condensing) Non-operating Relative Humidity: 5% to 95% (non-condensing) |
パーツ仕様
パーツリスト | |||
---|---|---|---|
型番 | 数量 | 内容 | |
Motherboard / Chassis |
MBD-X11DPU-Z+ CSE-829U2AC4-R1K62-T |
1 1 |
Super X11DPU-Z+ Motherboard CSE-829U2AC4-R1K62-T |
Add-on Card / Module | AOC-2UR68-I4G-P | 1 | 2U Ultra Riser based on Intel i350AM4 controller with 4 GbE RJ45 ports, 1 internal PCI-E x8 3.0 slot, 1 PCI-E x16 3.0, and I PCI-E x8 3.0 (in x16 slot) |
Backplane | BPN-SAS3-826A-N4 | 1 | 12-port 2U SAS3 12Gbps hybrid backplane, support up to 8x 3.5-inch SAS3/SATA3 HDD/SSD and 4x SAS3/SATA3/NVMe Storage Devices |
Cable 1 | CBL-0306L | 1 | CBL,FRONT CNTL,16 TO 16 PIN,RA,RND TUBE,65CM,28AWG |
Cable 2 | CBL-PWEX-0652 | 1 | 8 pin female to 2x RA(Right Angle) big 4 pin female power, 60/65CM, 18AWG,RoHS/REACH |
Cable 3 | CBL-PWEX-0673 | 1 | 8 pin female to 2x big 4 pin female power, 65/70CM, 18AWG,RoHS/REACH |
Cable 4 | CBL-SAST-0591 | 1 | MINI SAS HD-4 SATA,6G,INT,RF,Cross Over,75CM,75CM SB,30AWG |
Cable 5 | CBL-SAST-0655 | 1 | MINI SAS HD(ST)-MINI SAS(RA-RS EXIT),6G,INT,47CM,SB,30AWG |
Cable 6 | CBL-SAST-0657 | 1 | MINI SAS HD(ST)-MINI SAS(RA-RS EXIT),6G,INT,55CM,SB,30AWG |
Air Shroud | MCP-310-82921-0N | 1 | Plastic air shroud for SC829U, 219U (X11 24DIMM, left side) |
Air Shroud | MCP-310-82922-0N | 1 | Plastic air shroud for SC829U, 219U (X11 24DIMM, right side) |
Riser Card | RSC-R1UW-E8R | 1 | 1U RHS WIO Riser card with one PCI-E x8 slot |
Riser Card | RSC-R2UW-4E8 | 1 | 2U LHS WIO Riser card with four PCI-E x4 slots |
Heatsink / Retention | SNK-P0068PS | 2 | 2U Passive CPU Heat Sink for X11 Purley Platform Equipped with a Narrow Retention Mechanism |
* Power Supply | PWS-1K62A-1R | 2 | AC-DC 1600W, Titanium Level, Redundancy, 1U, DC Output: +12V and +12Vs, 203 x 73.5 x 40 mm, AC Input: 90 - 264 VAC/47-63Hz, PMBus 1.2 with DSP controller,HF,RoHS/REACH |
* Cable 7 | CBL-0088L | 4 | 4 PIN MIDDLE FAN POWER CABLE (PWM). 27cm, 24AWG |
* Cable 8 | CBL-0160L | 2 | NEMA5-15P to C13 US power cord 16AWG 6ft, PBF (default for high watt) |
* Cable 9 | CBL-0318L | 1 | CBL,FRONT CNTL,16 TO 16 PIN,RA,RND TUBE,24CM,28AWG |
* FAN 1 | FAN-0118L4 | 4 | 80 x 80 x 38 mm, 9.5K RPM, 4-pin PWM Fan, Hot |
* Parts | MCP-150-00009-0B | 1 | Internal AOC rubber support for SC819U, 119U |
* Drive Tray(s) | MCP-220-00075-0B | 1 2 |
Black gen 5.5 hot-swap 3.5"; HDD tray |
* Rail Set | MCP-290-00057-0N | 1 | Rail set, quick/quick, default for 4U 17.2"; W |
* Rail Set | MCP-290-00060-0N | 1 | Threaded rail adapter default for round hole rack |
* Air Shroud | MCP-310-81905-0B | 1 | Plastic air shroud for SC819U, 119U, 829U, 219U (PWS),RoHS/REACH |
* Front Panel | TB826 | 1 | Front panel adaptor board (TB826) forSC826,213,216,219 |
* Rail Set | MCP-290-00115-0N | 1 | Inner rail, quick-release type |
* Rail Set | MCP-290-00117-0N | 1 | Outer rail, quick-release type |
オプションパーツリスト | |||
型番 | 数量 | 内容 | |
Add-on card for internal M.2 NVMe | AOC-SLG3-2M2 | 1 | Low Profile PCI-E x8 add-on card supports 2 PCI-E 3.0 x4 M-Key M.2 NVMe Modules |
2U Ultra optional rear drive kit | MCP-240-82922-0N-OEM | 1 | Rear 2x2.5" HDDs riser bracket kit for SC829U/219U, tool-less |
2 Rear 2.5" Hot-swap SATA Drive Bays | MCP-240-82922-0N-OEM | - | Rear 2x 2.5" HDDs riser bracket kit for SC829U/219U, tool-less |
Storage Control Card and Cable for 4x Hybrid NVMe/SAS Drive Bays |
AOC-S3008L-L8e & 2 CBL-SAST-0593 (1~2) AOC-S3008L-L8i & 2 CBL-SAST-0593 (1~2) AOC-S3108L-H8iR & 2 CBL-SAST-0593 (1~2) AOC-S3108L-H8iR-16DD & 2 CBL-SAST-0593 (1~2) |
- |
Std LP, 8 internal ports, 12Gb/s per port- Gen3, 122HDD, HBA Std LP, 8 internal ports, 12Gb/s per port- Gen3, 63HDD, RAID 0,1,1E Std LP, 8 internal ports, 12Gb/s per port- Gen3, 240HDD, RAID 0, 1, 5, 6, 10, 50, 60 LSI 3108 based SAS3 RAID, 12Gb, 8 internal ports, 16 drives with expander - RAID 0,1,10,5,6,50,60, Gen3 x8 Standard Low Profile |
Cable for 4 NVMe Hybrid Drive Bays | 2 CBL-SAST-0929 & 2 CBL-SAST-0972 |
1 | OCuLink source to MiniSAS HD target V.91,INT,PCIe NVMe SSD, 57CM,34AWG |
Hot-swap 3.5" to 2.5" NVMe Drive Tray | MCP-220-00138-0B | 1 ~ 4 | Tool-less black hot-swap 3.5-to-2.5 converter NVMe drive tray (Orange tab) |
2 Internal M.2 slots (1 SATA, 1 NVMe) | RSC-UMR-8 & CBL-SAST-0538 & MCP-120-82924-0N & MCP-310-21902-0N |
1 | 1U Ultra RHS Riser Card with 1 PCIE/SATA Hybrid M.2 &1 PCIE X8 |
Cable for internal M.2 SATA | CBL-SAST-0538 | 1 | 29cm 30AWG SATA S-RA cable |
Network Card(s) |
AOC-SGP-i2/4 AOC-STGN-i1S/i2S AOC-STGF-i2S AOC-STG-i4S AOC-STG-b4S AOC-STG-i2T AOC-STGS-i1/2T AOC-STG-i4T AOC-STG-i2 AOC-S25G-m2S AOC-S40G-i2Q More |
- - - - - - - - - - - - |
Standard LP, 2/4x GbE RJ45, PCI-E x4, Intel i350 Standard LP, 1/2x 10GbE SFP+, PCI-E x8, Intel 82599EN Standard LP, 2x 10GbE SFP+, PCI-E x8, Intel XL710-BM2 Standard LP, 4x 10GbE SFP+, PCI-E x8, Intel XL710 Standard LP, 4x 10GbE SFP+, PCI-E x8, Broadcom BCM57840S Standard LP, 2x 10GbE RJ45, PCI-E x8, Intel X540 Standard LP, 1/2x 10GbE RJ45, PCI-E x8, Intel X550 Standard LP, 4x 10GbE RJ45, PCI-E x8, Intel XL710 Standard LP, 2x 10GbE CX4, PCI-E x8, Intel 82598EB Standard LP, 2x 25GbE SFP28, Mellanox ConnectX-4 LX EN Standard LP 2-port 40GbE controller, Intel Fortville XL710 AOC Compatibility Matrix |
2U Cable Management Arm | MCP-290-00128-0N & MCP-290-00127-0N |
1 | 2U Supermicro Cable Management Arm 2nd Gen (Compatible for racks that are 42" in depth) |
CacheVault(s) | BTR-CV3108-U1 | - | CacheVault for Broadcom 3108 with Supercap mounting for 2U Ultra |
TPM security module | AOM-TPM-9670V | 1 | SPI capable TPM 2.0 with Infineon 9670 controller, Vertical form factor |
TPM security module | AOM-TPM-9671V | 1 | SPI capable TPM 1.2 with Infineon 9670 controller, Vertical form factor |
Intel VROC RAID Key | AOC-VROCINTMOD AOC-VROCSTNMOD AOC-VROCPREMOD |
1 1 1 |
Intel VROC, RAID 0, 1, 5, 10 (Intel SSD Only) Intel VROC Standard, RAID 0, 1, 10 Intel VROC Premium, RAID 0, 1, 5, 10 |
Global Services & Support | OS4HR3/2/1 OSNBD3/2/1 |
- - |
3/2/1-year onsite 24x7x4 service 3/2/1-year onsite NBD service |
Software |
SFT-OOB-LIC OOB Management Package (per node license) consists of: • (X10 or Later Only) OOB System Checks such as Asset Information, System Utilization, Sensor Data • (X10 or Later Only) BIOS and BMC System Event Log management • BIOS Management functions such as in-band/OOB BIOS updates, provision BIOS config and DMI settings • BMC Management functions such as OOB BMC F/W updates and provisioning F/W settings • (X10 or Later Only) TPM provisioning • Scripting capabilities to mount virtual media Software tools: SUM ',ABOVE,ol_width=750,ol_border=1,ol_cellpad=6);" target="_blank">SFT-OOB-LIC • 1 |
OOB Management Package (per node license) | |
Software | SFT-DCMS-Single DataCenter Management Package (per node license) consists of: • OOB Management package capabilities provided by SFT-OOB-LIC • Centralized Management Console licenses for health monitoring, power management and firmware upgrades • RESTful API support to integrate server management into existing management infrastructure (roadmap Q1’15) • Advanced Power Management licenses to manage power on heterogeneous server vendor products • Remote Software installation support • Remote debug assistance directly from product engineers Software tools: SSM, SPM, SUM',ABOVE,ol_width=750,ol_border=1,ol_cellpad=6);">SFT-DCMS-Single |
1 | DataCenter Management Package (per node license) |