SYS-4029GP-TRT3
製品種別 | サーバ |
---|---|
CPUソケット数 | 2 |
CPU | |
筐体サイズ | 4U |
最大GPU数 | 8 |
電源仕様 | リダンダント電源 |
用途/特長 | |
製品説明 |
製品仕様
Product SKUs | SYS-4029GP-TRT3 | SuperServer 4029GP-TRT3 (Black) |
---|---|
プロセッサ/キャッシュ | CPU | Dual Socket P (LGA 3647) 2nd Gen. Intel® Xeon® Scalable Processors (Cascade Lake/Skylake)‡,3 UPI up to 10.4GT/s Support CPU TDP 70-205W |
Cores | Up to 28 Cores |
Note | ‡ BIOS version 3.0a or above is required to support 2nd Gen. Intel® Xeon® Scalable processors |
GPU Support | Please refer to: Compatible GPU list |
メモリ | Memory Capacity | 24 DIMM slots Up to 6TB 3DS ECC DDR4-2933MHz† RDIMM/LRDIMM Supports Intel® Optane™ DCPMM†† |
Memory Type | 2933†/2666/2400/2133MHz ECC DDR4 RDIMM/LRDIMM |
Note | † 2933MHz in two DIMMs per channel can be achieved by using memory purchased from Supermicro†† Cascade Lake only. Contact your Supermicro sales rep for more info. |
オンボードデバイス | Chipset | Intel® C622 chipset |
SATA | SATA3 (6Gbps) with RAID 0, 1, 5, 10 |
Network Controllers | Dual Port 10GbE from C622 |
IPMI | Support for Intelligent Platform Management Interface v.2.0 IPMI 2.0 with virtual media over LAN and KVM-over-LAN support |
Graphics | ASPEED AST2500 BMC |
標準インターフェース | SATA | 10 SATA3 (6Gbps) ports |
LAN | 2 RJ45 10GBase-T LAN ports 1 RJ45 Dedicated IPMI LAN port |
USB | 4 USB 3.0 ports (rear) |
Video | 1 VGA Connector |
COM Port | 1 COM port (header) |
BIOS | BIOS Type | AMI 32Mb SPI Flash ROM |
マネージメント | Software | Intel® Node Manager IPMI 2.0 KVM with dedicated LAN SSM, SPM, SUM SuperDoctor® 5 Watchdog |
システム監視機能 | CPU | Monitors for CPU Cores, Chipset Voltages, Memory. 4+1 Phase-switching voltage regulator |
FAN | Fans with tachometer monitoring Status monitor for speed control Pulse Width Modulated (PWM) fan connectors |
Temperature | Monitoring for CPU and chassis environment Thermal Control for fan connectors |
シャーシ | Form Factor | 4U Rackmountable Rackmount Kit (MCP-290-00057-0N) |
Model | CSE-418GTS-R4000BP2 |
外形寸法/重量 | Height | 7.0" (178mm) |
Width | 17.2" (437mm) |
Depth | 29" (737mm) |
Weight | Net Weight: 65.5 lbs (29.7 kg) Gross Weight: 100 lbs (45.3 kg) |
Available Colors | Black |
ドライブベイ・ストレージ | Hot-swap | Up to 24x 2.5" SAS/SATA drive bays 8x 2.5" SATA supported natively 2x 2.5" NVMe supported natively |
M.2 | 1 NVMe based M.2 SSD Form Factors: 2260, 2280, 22110 |
拡張スロット | PCI-Express | 11 PCI-E 3.0 x16 (FH, FL) slots 1 PCI-E 3.0 x8 (FH, FL, in x16) slot |
冷却機構 | Fans | 8x 92mm heavy duty counter-rotating fans |
電源 | Total Output Power | 1000W: 100 – 120Vac 1800W: 200 – 220Vac 1980W: 220 – 230Vac 2000W: 230 – 240Vac 2000W: 200 – 240Vac (UL/CUL only) |
Dimension(W x H x L) | 73.5 x 40 x 265 mm |
Input | 100-120Vac / 12.5-9.5A / 50-60Hz 200-220Vac / 10-9.5A / 50-60Hz 220-230Vac / 10-9.8A / 50-60Hz 230-240Vac / 10-9.8A / 50-60Hz 200-240Vac / 11.8-9.8A / 50-60Hz (UL/cUL only) |
+12V | Max: 83.3A / Min: 0A (100-120Vac) Max: 150A / Min: 0A (200-220Vac) Max: 165A / Min: 0A (220-230Vac) Max: 166.7A / Min: 0A (230-240Vac) Max: 166.7A / Min: 0A (200-240Vac) (UL/cUL only) |
12Vsb | Max: 2.1A / Min: 0A |
Output Type | 25 Pairs Gold Finger Connector |
Certification | Titanium Level [ Test Report ] |
動作環境 | RoHS | RoHS Compliant |
Environmental Spec. | Operating Temperature: 10°C ~ 35°C (50°F ~ 95°F) Non-operating Temperature: -40°C to 60°C (-40°F to 140°F) Operating Relative Humidity: 8% to 90% (non-condensing) Non-operating Relative Humidity: 5% to 95% (non-condensing) |
パーツ仕様
パーツリスト | |||
---|---|---|---|
型番 | 数量 | 内容 | |
Motherboard / Chassis |
MBD-X11DPG-OT-CPU MBD-X11DPG-O-PCIE CSE-418GTS-R4000BP2 |
1 1 1 |
Super X11DPG-OT-CPU Motherboard Super X11DPG-O-PCIE Motherboard CSE-418GTS-R4000BP2 Chassis |
Backplane | BPN-SAS3-216A-N4 | 1 | 24-port 2U SAS3 12Gbps hybrid backplane, support up to 20x 2.5-inch SAS3/SATA3 HDD/SSD and 4x SAS3/SATA3/NVMe Storage Devices |
Cable 1 | CBL-0449L | 2 | HDD power extension for X8OBN, special 8 pin to 4 HDD. 45cm. 18AWG |
Cable 2 | CBL-PWEX-1028 | 8 | GPU,2x4F/CPU to 2x4F/CPU,P4.2, 30CM,16AWG, 10A/pin, -40~105C |
Cable 3 | CBL-SAST-0507-01 | 2 | MINI SAS HD-MINI SAS,6G,INT,80CM,SB,28AWG |
Cable 4 | CBL-SAST-0972 | 2 | OcuLink V. 1.0 source to MiniSAS HD,INT,PCIe, 70CM,34AWG,RoH |
Parts | MCP-130-41802-0B | 1 | Black plastic palm cover for X10DRG-O-PCIE |
Riser Card | RSC-X9DRG-O | 4 | RSC-X9DRG-O |
Heatsink / Retention | SNK-P0068APS4 | 2 | 2U Active CPU Heat Sink Supporting Narrow Bolster Plate Mounting Mechanism for X11 Purley Platform |
* Power Supply | PWS-2K05A-1R | 4 | 1U 2000W Redundant Titanium Power Supply W/PMbus 73.5x40x265mm,RoHS/REACH |
* Cable 5 | CBL-0071L | 1 | CBL,FRONT CNTL,16 TO 16 PIN,RA,RND TUBE,75CM,28AWG |
* Cable 6 | CBL-0174L | 4 | PWCD,US,NEMA5-15P TO IEC60320 C13,6FT,14AWG,15A,125V,RoHS/REACH |
* FAN 1 | FAN-0151L4 | 8 | 92x92x38 mm, 11.5K RPM, SC418G Middle Fan w/ Housing,RoHS/REACH,PBF |
* Drive Tray(s) | MCP-220-00047-0B | 2 4 |
Black gen 3rd hot-swap 2.5inch HDD tray |
* Rear Window | MCP-240-84802-0N | 1 | 21 slot rear window for SC418X |
* Parts | MCP-260-41801-0N | 1 | IO shield for X9DRG-O in SC418G |
* Front Panel | MCP-280-82601-0N | 1 | Front control board adapter (TB826) for SC216,826,936,846 |
* Rail Set | MCP-290-00057-0N | 1 set | Rail set, quick/quick, default for 4U 17.2"; W |
* Rail Set | MCP-290-00060-0N | 1 | Threaded rail adapter default for round hole rack |
* Drive Tray(s) | MCP-290-21301-0B | 3 | Black 2.5\" HDD dummy cover for SC213,216 (Cover 8 HDD) |
* Rail Set | MCP-290-00115-0N | 1 | Inner rail, quick-release type |
* Rail Set | MCP-290-00117-0N | 1 | Outer rail, quick-release type |
* FAN 2 | MCP-340-00044-0N | 1 | 92x92x38 mm, 11.5K RPM, 4-pin PWM Bare Fan |
オプションパーツリスト | |||
型番 | 数量 | 内容 | |
NVIDIA Quadro & Generic GPU Cables | CBL-PWEX-1040 | 1 per GPU | GPU,2x4M/CPU to two (2x3F+2x1F)/PCIe,P4.2, 5CM,16/20AWG, 10.5A/pin(16AWG), 8A/pin(20AWG), -25~85C,RoHS |
Storage Control Card and Cable for 2x Hybrid NVMe/SAS Drive Bays | AOC-S3008L-L8e & CBL-SAST-0531 AOC-S3008L-L8i & CBL-SAST-0531 AOC-S3108L-H8iR & CBL-SAST-0531 |
1 AOC + 2 CBL 1 AOC + 2 CBL 1 AOC + 2 CBL |
Std LP, 8 internal ports, 12Gb/s per port- Gen3, 122 HDD, HBA Std LP, 8 internal ports, 12Gb/s per port- Gen3, 63 HDD, RAID 0,1,1E Std LP, 8 internal ports, 12Gb/s per port- Gen3, 240 HDD, RAID 0,1,5,6,10,50,60 |
2.5" NVMe Drive Trays | MCP-220-00121-0B MCP-220-00167-0B |
1-2 | Black Gen-3 2.5" NVMe drive tray, Orange tab with lock Tool-less black hot-swap 2.5" NVMe drive tray (Orange tab, w/ key lock, clip design) |
Super Cap for LSI 3108 | BKT-BBU-BRACKET-05 BTR-TFM8G-LSICVM02 |
1 1 |
Mounting Bracket for LSI BBUs LSI Super Cap |
Global Services & Support | OS4HR3/2/1 OSNBD3/2/1 |
- - |
3/2/1-year onsite 24x7x4 service 3/2/1-year onsite NBD service |
Software |
SFT-OOB-LIC OOB Management Package (per node license) consists of: • (X10 or Later Only) OOB System Checks such as Asset Information, System Utilization, Sensor Data • (X10 or Later Only) BIOS and BMC System Event Log management • BIOS Management functions such as in-band/OOB BIOS updates, provision BIOS config and DMI settings • BMC Management functions such as OOB BMC F/W updates and provisioning F/W settings • (X10 or Later Only) TPM provisioning • Scripting capabilities to mount virtual media Software tools: SUM ',ABOVE,ol_width=750,ol_border=1,ol_cellpad=6);" target="_blank">SFT-OOB-LIC • 1 |
OOB Management Package (per node license) | |
Software | SFT-DCMS-Single DataCenter Management Package (per node license) consists of: • OOB Management package capabilities provided by SFT-OOB-LIC • Centralized Management Console licenses for health monitoring, power management and firmware upgrades • RESTful API support to integrate server management into existing management infrastructure (roadmap Q1’15) • Advanced Power Management licenses to manage power on heterogeneous server vendor products • Remote Software installation support • Remote debug assistance directly from product engineers Software tools: SSM, SPM, SUM',ABOVE,ol_width=750,ol_border=1,ol_cellpad=6);">SFT-DCMS-Single |
1 | DataCenter Management Package (per node license) |