製品情報

SYS-2029UZ-TR4_

製品種別 サーバ
CPUソケット数
CPU  
 
筐体サイズ 2U
最大GPU数
電源仕様 リダンダント電源
用途/特長  
製品説明

Supermicroについて


製品仕様

Product SKUs
SYS-2029UZ-TR4+ SuperServer 2029UZ-TR4+ (Black)
プロセッサ/キャッシュ
CPU Dual Socket P (LGA 3647)
2nd Gen. Intel® Xeon® Scalable Processors (Cascade Lake/Skylake),
3 UPI up to 10.4GT/s
Support CPU TDP 70-205W
Cores Up to 28 Cores
Note BIOS version 3.0a or above is required to support 2nd Gen. Intel® Xeon® Scalable processors
メモリ
Memory Capacity 24 DIMM slots
Up to 6TB 3DS ECC DDR4-2933MHz RDIMM/LRDIMM
Supports Intel® Optane™ DCPMM††
Memory Type 2933/2666/2400/2133MHz ECC DDR4 RDIMM/LRDIMM
Note 2933MHz in two DIMMs per channel can be achieved by using memory purchased from Supermicro
†† Cascade Lake only. Contact your Supermicro sales rep for more info.
オンボードデバイス
Chipset Intel® C621 chipset
SATA SATA3 (6Gbps); RAID 0, 1, 5, 10
Network Connectivity 4x 1GbE LAN ports via Intel® i350 (AOC-2UR68-i4G)
IPMI Support for Intelligent Platform Management Interface v.2.0
IPMI 2.0 with virtual media over LAN and KVM-over-LAN support
Graphics ASPEED AST2500 BMC
標準インターフェース
SATA 10 SATA3 (6Gbps) ports
LAN 4 GbE ports
1 RJ45 Dedicated IPMI LAN port
USB 3 USB 3.0 ports (2 rear, 1 Type A)
Video 2 VGA ports (1 rear, 1 onboard)
Serial Port 1 Serial header
DOM 2 SuperDOM (Disk on Module) ports
BIOS
BIOS Type AMI 32Mb SPI Flash ROM
マネージメント
Software Intel® Node Manager
Redfish API
IPMI 2.0
KVM with dedicated LAN
NMI
SSM, SPM, SUM
SuperDoctor® 5
Power Configurations ACPI Power Management
システム監視機能
CPU Monitors for CPU Cores, Chipset Voltages, Memory.
4+1 Phase-switching voltage regulator
FAN Fans with tachometer monitoring
Status monitor for speed control
Pulse Width Modulated (PWM) fan connectors
Temperature Monitoring for CPU and chassis environment
Thermal Control for fan connectors
シャーシ
Form Factor 2U Rackmount
Model CSE-219U2AC4-R1K62-T
外形寸法・重量
Height 3.5" (89mm)
Width 17.2" (437mm)
Depth 27.76" (705mm)
Weight Net Weight: 36 lbs (16.4 kg)
Gross Weight: 72 lbs (32.7 kg)
Available Color Black
フロントパネル
Buttons Power On/Off button
System UID button
LEDs Power LED
Hard drive activity LED
Network activity LEDs
UID LED
拡張スロット
PCI-Express 1 PCI-E 3.0 x16 slot (FH, 10.5"L)
5 PCI-E 3.0 x8 slot (FH, 10.5"L)
1 PCI-E 3.0 x8 slot (LP)
1 PCI-E 3.0 x8 slot (internal LP)
ドライブベイ・ストレージ
Hot-swap 24 Hot-swap 2.5" drive bays
Optional 20 SAS3 + 4 SAS3/NVMe
2 Rear Hot-swap 2.5" drive bays
M.2 1 M.2 PCI-E 3.0 x4 M-Key NVMe or 1 M.2 M-Key SATA3 (2240/2260/2280/22110) via optional riser card (see optional parts list)
2 M.2 PCI-E 3.0 x4 M-Key NVMe (2260/2280/22110) via optional add-on card AOC-SLG3-2M2
冷却機構
Fans 4 Heavy duty 8cm fans
電源
Total Output Power 1600W/1000W
Dimension
(W x H x L)
73.5 x 40 x 203 mm
Input 100-127Vac / 13 - 9A / 50-60Hz
200-240Vac / 10 - 8A / 50-60Hz
+12V Max: 83.3A / Min: 0A (100-127Vac)
Max: 133A / Min: 0A (200-240Vac)
12Vsb Max: 2.1A / Min: 0A
Output Type 25 Pairs Gold Finger Connector
Certification   Titanium Level
  [ Test Report ]
動作環境
RoHS RoHS Compliant
Environmental Spec. Operating Temperature:
   10°C ~ 35°C (50°F ~ 95°F)
Non-operating Temperature:
   -40°C to 60°C (-40°F to 140°F)
Operating Relative Humidity:
   8% to 90% (non-condensing)
Non-operating Relative Humidity:
   5% to 95% (non-condensing)

パーツ仕様

パーツリスト
型番 数量 内容
Motherboard / Chassis MBD-X11DPU-Z+
CSE-219U2AC4-R1K62-T
1
1
Super X11DPU-Z+ Motherboard
CSE-219U2AC4-R1K62-T
Add-on Card / Module AOC-2UR68-I4G-P 1 2U Ultra Riser based on Intel i350AM4 controller with 4 GbE RJ45 ports, 1 internal PCI-E x8 3.0 slot, 1 PCI-E x16 3.0, and I PCI-E x8 3.0 (in x16 slot)
Backplane BPN-SAS3-216A-N4 1 24-port 2U SAS3 12Gbps hybrid backplane, support up to 20x 2.5-inch SAS3/SATA3 HDD/SSD and 4x SAS3/SATA3/NVMe Storage Devices
Cable 1 CBL-0306L 1 CBL,FRONT CNTL,16 TO 16 PIN,RA,RND TUBE,65CM,28AWG
Cable 2 CBL-PWEX-0673 3 8 pin female to 2x big 4 pin female power, 65/70CM, 18AWG,RoHS/REACH
Cable 3 CBL-SAST-0591 1 MINI SAS HD-4 SATA,6G,INT,RF,Cross Over,75CM,75CM SB,30AWG
Cable 4 CBL-SAST-0655 1 MINI SAS HD(ST)-MINI SAS(RA-RS EXIT),6G,INT,47CM,SB,30AWG
Cable 5 CBL-SAST-0657 1 MINI SAS HD(ST)-MINI SAS(RA-RS EXIT),6G,INT,55CM,SB,30AWG
Air Shroud MCP-310-82921-0N 1 Plastic air shroud for SC829U, 219U (X11 24DIMM, left side)
Air Shroud MCP-310-82922-0N 1 Plastic air shroud for SC829U, 219U (X11 24DIMM, right side)
Riser Card RSC-R1UW-E8R 1 1U RHS WIO Riser card with one PCI-E x8 slot
Riser Card RSC-R2UW-4E8 1 2U LHS WIO Riser card with four PCI-E x4 slots
Heatsink / Retention SNK-P0068PS 2 2U Passive CPU Heat Sink for X11 Purley Platform Equipped with a Narrow Retention Mechanism
* Power Supply PWS-1K62A-1R 2 AC-DC 1600W, Titanium Level, Redundancy, 1U, DC Output: +12V and +12Vs, 203 x 73.5 x 40 mm, AC Input: 90 - 264 VAC/47-63Hz, PMBus 1.2 with DSP controller,HF,RoHS/REACH
* Cable 6 CBL-0088L 4 4 PIN MIDDLE FAN POWER CABLE (PWM). 27cm, 24AWG
* Cable 7 CBL-0160L 2 NEMA5-15P to C13 US power cord 16AWG 6ft, PBF (default for high watt)
* Cable 8 CBL-0318L 1 CBL,FRONT CNTL,16 TO 16 PIN,RA,RND TUBE,24CM,28AWG
* FAN 1 FAN-0158L4 4 80x80x38 mm, 10.5K RPM, Optional Middle Cooling Fan for X10 2U Ultra and HFT Series Servers,RoHS/REACH
* Drive Tray(s) MCP-220-00047-0B 2
4
Black gen 3rd hot-swap 2.5inch HDD tray
* Rail Set MCP-290-00057-0N 1 Rail set, quick/quick, default for 4U 17.2"; W
* Rail Set MCP-290-00060-0N 1 Threaded rail adapter default for round hole rack
* Air Shroud MCP-310-81905-0B 1 Plastic air shroud for SC819U, 119U, 829U, 219U (PWS),RoHS/REACH
* Front Panel TB826 1 Front panel adaptor board (TB826) forSC826,213,216,219
* Rail Set MCP-290-00115-0N 1 Inner rail, quick-release type
* Rail Set MCP-290-00117-0N 1 Outer rail, quick-release type
オプションパーツリスト
型番 数量 内容
Add-on card for internal M.2 NVMe AOC-SLG3-2M2 1 Low Profile PCI-E x8 add-on card supports 2 PCI-E 3.0 x4 M-Key M.2 NVMe Modules
2U Ultra optional rear drive kit MCP-240-82922-0N-OEM 1 Rear 2x2.5" HDDs riser bracket kit for SC829U/219U, tool-less
2 Rear 2.5" Hot-swap SATA Drive Bays MCP-240-82922-0N-OEM - Rear 2x 2.5" HDDs riser bracket kit for SC829U/219U, tool-less
Storage Control Card and Cable for 4x Hybrid NVMe/SAS Drive Bays AOC-S3008L-L8e &
2 CBL-SAST-0593 (1~3)
AOC-S3008L-L8i &
2 CBL-SAST-0593 (1~3)
AOC-S3108L-H8iR &
2 CBL-SAST-0593 (1~3)
AOC-S3108L-H8iR-16DD
& 2 CBL-SAST-0593 (1~3)
- Std LP, 8 internal ports, 12Gb/s per port- Gen3, 122HDD, HBA

Std LP, 8 internal ports, 12Gb/s per port- Gen3, 63HDD, RAID 0,1,1E
Std LP, 8 internal ports, 12Gb/s per port- Gen3, 240HDD, RAID 0, 1, 5, 6, 10, 50, 60
LSI 3108 based SAS3 RAID, 12Gb, 8 internal ports, 16 drives with expander - RAID 0,1,10,5,6,50,60, Gen3 x8 Standard Low Profile
Cable for 4 NVMe Hybrid Drive Bays 2 CBL-SAST-0929 &
2 CBL-SAST-0972
1 OCuLink source to MiniSAS HD target V.91,INT,PCIe NVMe SSD, 57CM,34AWG
2.5" NVMe Drive Trays MCP-220-00167-0B
MCP-220-00127-0B
1 ~ 4 Tool-less black hot-swap 2.5" NVMe drive tray (Orange tab, w/ key lock, clip design)
Black hot-swap 2.5" NVMe drive tray (Orange tab, w/ key lock)
2 Internal M.2 slots
(1 SATA, 1 NVMe)
RSC-UMR-8 &
CBL-SAST-0538 &
MCP-120-82924-0N &
MCP-310-21902-0N
1 1U Ultra RHS Riser Card with 1 PCIE/SATA Hybrid M.2 &1 PCIE X8
Cable for internal M.2 SATA CBL-SAST-0538 1 29cm 30AWG SATA S-RA cable
Network Card(s) AOC-SGP-i2/4
AOC-STGN-i1S/i2S
AOC-STGF-i2S
AOC-STG-i4S
AOC-STG-b4S
AOC-STG-i2T
AOC-STGS-i1/2T
AOC-STG-i4T
AOC-STG-i2
AOC-S25G-m2S
AOC-S40G-i2Q
More
-
-
-
-
-
-
-
-
-
-
-
-
Standard LP, 2/4x GbE RJ45, PCI-E x4, Intel i350
Standard LP, 1/2x 10GbE SFP+, PCI-E x8, Intel 82599EN
Standard LP, 2x 10GbE SFP+, PCI-E x8, Intel XL710-BM2
Standard LP, 4x 10GbE SFP+, PCI-E x8, Intel XL710
Standard LP, 4x 10GbE SFP+, PCI-E x8, Broadcom BCM57840S
Standard LP, 2x 10GbE RJ45, PCI-E x8, Intel X540
Standard LP, 1/2x 10GbE RJ45, PCI-E x8, Intel X550
Standard LP, 4x 10GbE RJ45, PCI-E x8, Intel XL710
Standard LP, 2x 10GbE CX4, PCI-E x8, Intel 82598EB
Standard LP, 2x 25GbE SFP28, Mellanox ConnectX-4 LX EN
Standard LP 2-port 40GbE controller, Intel Fortville XL710
AOC Compatibility Matrix
2U Cable Management Arm MCP-290-00128-0N &
MCP-290-00127-0N
1 2U Supermicro Cable Management Arm 2nd Gen (Compatible for racks that are 42" in depth)
CacheVault(s) BTR-CV3108-U1 - CacheVault for Broadcom 3108 with Supercap mounting for 2U Ultra
TPM security module AOM-TPM-9670V 1 SPI capable TPM 2.0 with Infineon 9670 controller,
Vertical form factor
TPM security module AOM-TPM-9671V 1 SPI capable TPM 1.2 with Infineon 9670 controller,
Vertical form factor
Intel VROC RAID Key AOC-VROCINTMOD
AOC-VROCSTNMOD
AOC-VROCPREMOD
1
1
1
Intel VROC, RAID 0, 1, 5, 10 (Intel SSD Only)
Intel VROC Standard, RAID 0, 1, 10
Intel VROC Premium, RAID 0, 1, 5, 10
Global Services & Support OS4HR3/2/1
OSNBD3/2/1
-
-
3/2/1-year onsite 24x7x4 service
3/2/1-year onsite NBD service
Software SFT-OOB-LIC
OOB Management Package (per node license) consists of:
  • (X10 or Later Only) OOB System Checks such as Asset Information, System Utilization, Sensor Data
  • (X10 or Later Only) BIOS and BMC System Event Log management
  • BIOS Management functions such as in-band/OOB BIOS updates, provision BIOS config and DMI settings
  • BMC Management functions such as OOB BMC F/W updates and provisioning F/W settings
  • (X10 or Later Only) TPM provisioning
  • Scripting capabilities to mount virtual media

Software tools: SUM
',ABOVE,ol_width=750,ol_border=1,ol_cellpad=6);" target="_blank">SFT-OOB-LIC 1
OOB Management Package (per node license)
Software SFT-DCMS-Single
DataCenter Management Package (per node license) consists of:
  • OOB Management package capabilities provided by SFT-OOB-LIC
  • Centralized Management Console licenses for health monitoring, power management and firmware upgrades
  • RESTful API support to integrate server management into existing management infrastructure (roadmap Q1’15)
  • Advanced Power Management licenses to manage power on heterogeneous server vendor products
  • Remote Software installation support
  • Remote debug assistance directly from product engineers

Software tools: SSM, SPM, SUM',ABOVE,ol_width=750,ol_border=1,ol_cellpad=6);">SFT-DCMS-Single
1 DataCenter Management Package (per node license)