SYS-2029U-TR25M
製品種別 | サーバ |
---|---|
CPUソケット数 | |
CPU | |
筐体サイズ | 2U |
最大GPU数 | |
電源仕様 | リダンダント電源 |
用途/特長 | |
製品説明 |
製品仕様
Product SKUs | SYS-2029U-TR25M | SuperServer 2029U-TR25M (Black) |
---|---|
プロセッサ/キャッシュ | CPU | Dual Socket P (LGA 3647) 2nd Gen. Intel® Xeon® Scalable Processors (Cascade Lake/Skylake)‡,Dual UPI up to 10.4GT/s Support CPU TDP 70-205W |
Cores | Up to 28 Cores |
Note | ‡ BIOS version 3.0a or above is required to support 2nd Gen. Intel® Xeon® Scalable processors |
メモリ | Memory Capacity | 24 DIMM slots Up to 6TB 3DS ECC DDR4-2933MHz† RDIMM/LRDIMM Supports Intel® Optane™ DCPMM†† |
Memory Type | 2933†/2666/2400/2133MHz ECC DDR4 RDIMM/LRDIMM 2666 ECC DDR4 NVDIMM |
Note | † 2933MHz in two DIMMs per channel can be achieved by using memory purchased from Supermicro†† Cascade Lake only. Contact your Supermicro sales rep for more info. |
オンボードデバイス | Chipset | Intel® C621 chipset |
SATA | SATA3 (6Gbps); RAID 0, 1, 5, 10 |
Network Connectivity | 2 25GbE SFP28 ports via AOC-2UR68-M2TS-O (Mellanox ConnectX-4 Lx EN) |
IPMI | Support for Intelligent Platform Management Interface v.2.0 IPMI 2.0 with virtual media over LAN and KVM-over-LAN support |
Graphics | ASPEED AST2500 BMC |
標準インターフェース | SATA | 14 SATA3 (6Gbps) ports |
LAN | 2 25GbE SFP28 ports 1 RJ45 Dedicated IPMI LAN port |
USB | 5 USB 3.0 ports(2 rear, 2 onboard header, 1 Type A) |
Video | 1 VGA Connector |
Serial Header | 1 Serial header |
DOM | 2 SuperDOM (Disk on Module) ports |
BIOS | BIOS Type | AMI 32Mb SPI Flash ROM |
マネージメント | Software | Intel® Node Manager Redfish API IPMI 2.0 KVM with dedicated LAN NMI SSM, SPM, SUM SuperDoctor® 5 |
Power Configurations | ACPI Power Management |
システム監視機能 | CPU | Monitors for CPU Cores, Chipset Voltages, Memory. 4+1 Phase-switching voltage regulator |
FAN | Fans with tachometer monitoring Status monitor for speed control Pulse Width Modulated (PWM) fan connectors |
Temperature | Monitoring for CPU and chassis environment Thermal Control for fan connectors |
シャーシ | Form Factor | 2U Rackmount |
Model | CSE-219U2AC4-R1K02-T |
外形寸法・重量 | Width | 17.2" (437mm) |
Height | 3.5" (89mm) |
Depth | 27.76" (705.3mm) |
Weight | Net Weight: 36 lbs (16.4 kg) Gross Weight: 72 lbs (32.7 kg) |
Available Colors | Black |
フロントパネル | Buttons | Power On/Off button System Reset button |
LEDs | Power status LED HDD activity LED Network activity LEDs System information (overheat/UID) LED |
拡張スロット | PCI-Express | 1 PCI-E 3.0 x16 (FH, 10.5" L) 5 PCI-E 3.0 x8 (FH, 10.5" L) 1 PCI-E 3.0 x8 (LP) 1 PCI-E 3.0 x8 (internal LP)(Both CPUs need to be installed for full access to PCI-E slots and onboard controllers. See manual block diagram and AOC Support for details.) |
ドライブベイ・ストレージ | Hot-swap | 24 Hot-swap 2.5" drive bays;14 SATA3 (optional 20 SAS3 + 4 NVMe/SAS3) |
M.2 | 1 M.2 PCI-E 3.0 x4 M-Key NVMe or 1 M.2 M-Key SATA3 (2240/2260/2280/22110) via optional riser card (see optional parts list) 2 M.2 PCI-E 3.0 x4 M-Key NVMe (2260/2280/22110) via optional add-on card AOC-SLG3-2M2 |
冷却機構 | Fans | 4 Heavy duty 8cm PWM fans |
電源 | Total Output Power | 800W: 100 – 127Vac 1000W: 200 – 240Vac 1000W: 200 – 240Vdc (for CCC only) |
Dimension(W x H x L) | 73.5 x 40 x 203 mm |
Input | 100-127Vac / 9.8 - 7A / 50-60Hz 200-240Vac / 7 - 5A / 50-60Hz 200-240Vdc / 7 - 5A (for CCC only) |
+12V | Max: 66.7A / Min: 0A (100-127Vac) Max: 83A / Min: 0A (200-240Vac) Max: 83A / Min: 0A (200-240Vdc) |
12Vsb | Max: 2.1A / Min: 0A |
Output Type | 25 Pairs Gold Finger Connector |
Certification | Titanium Level [ Test Report ] |
動作環境 | RoHS | RoHS Compliant |
Environmental Spec. | Operating Temperature: 10°C ~ 35°C (50°F ~ 95°F) Non-operating Temperature: -40°C to 60°C (-40°F to 140°F) Operating Relative Humidity: 8% to 90% (non-condensing) Non-operating Relative Humidity: 5% to 95% (non-condensing) |
パーツ仕様
パーツリスト | |||
---|---|---|---|
型番 | 数量 | 内容 | |
Motherboard / Chassis |
MBD-X11DPU CSE-219U2AC4-R1K02-T |
1 1 |
Super X11DPU Motherboard 2U Chassis |
Add-on Card / Module | AOC-2UR68-M2TS-P | 1 | 2U Ultra 2-port 25G SFP28, 1x PCI-E 3.0 x8 (internal) |
Backplane | BPN-SAS3-216A-N4 | 1 | 24-port 2U SAS3 12Gbps hybrid backplane, support up to 20x 2.5-inch SAS3/SATA3 HDD/SSD and 4x SAS3/SATA3/NVMe Storage Devices |
Cable 1 | CBL-PWEX-0673 | 3 | 8 pin female to 2x big 4 pin female power, 65/70CM, 18AWG,RoHS/REACH |
Cable 2 | CBL-SAST-0591 | 1 | MINI SAS HD-4 SATA,6G,INT,RF,Cross Over,75CM,75CM SB,30AWG |
Cable 3 | CBL-SAST-0655 | 1 | MINI SAS HD(ST)-MINI SAS(RA-RS EXIT),6G,INT,47CM,SB,30AWG |
Cable 4 | CBL-SAST-0656 | 1 | MINI SAS HD(ST)-MINI SAS(RA-RS EXIT),6G,INT,39CM,SB,30AWG |
Cable 5 | CBL-SAST-0657 | 1 | MINI SAS HD(ST)-MINI SAS(RA-RS EXIT),6G,INT,55CM,SB,30AWG |
Parts | MCP-240-82914-0N | 1 | Ultra I/O bracket for SC829U, 219U (B2TS) |
Air Shroud | MCP-310-82921-0N | 1 | Plastic air shroud for SC829U, 219U (X11 24DIMM, left side) |
Air Shroud | MCP-310-82922-0N | 1 | Plastic air shroud for SC829U, 219U (X11 24DIMM, right side) |
Riser Card | RSC-R1UW-E8R | 1 | 1U RHS WIO Riser card with one PCI-E x8 slot |
Riser Card | RSC-R2UW-4E8 | 1 | 2U LHS WIO Riser card with four PCI-E x8 slots |
Heatsink / Retention | SNK-P0068PS | 2 | 2U Passive CPU Heat Sink for X11 Purley Platform Equipped with a Narrow Retention Mechanism |
Power Supply | PWS-1K02A-1R | 2 | 1U 1000W Redundant Power Supply 73.5mm width Titanium Level,RoHS/REACH |
FAN 1 | FAN-0118L4 | 4 | 80 x 80 x 38 mm, 9.5K RPM, 4-pin PWM Fan, Hot |
オプションパーツリスト | |||
型番 | 数量 | 内容 | |
Add-on card for internal M.2 NVMe | AOC-SLG3-2M2 | 1 | Low Profile PCI-E x8 add-on card supports 2 PCI-E 3.0 x4 M-Key M.2 NVMe Modules |
2U Cable Management Arm | MCP-290-00128-0N & MCP-290-00127-0N |
1 | 2U Supermicro Cable Management Arm 2nd Gen (Compatible for racks that are 42" in depth) |
Internal Drive Tray for Two 2.5" Drives | MCP-120-82916-0N CBL-PWEX-0650 CBL-0080L CBL-0484L Or CBL-SAST-0654 Or CBL-SAST-0948 |
1 1 2 2 1 1 |
Internal drive plate Supports Two 2.5" Drive, PCI slots Power cable for Two internal 2.5" drives SATA3 S-S Cable miniSAS(iPass) to 4 SATA Cable miniSAS HD to 4 SATA Cable |
Cable for 4 NVMe Hybrid Drive Bays | 2 CBL-SAST-0929 & 2 CBL-SAST-0972 |
1 | OCuLink source to MiniSAS HD target V.91,INT,PCIe NVMe SSD, 57CM,34AWG |
2.5" NVMe Drive Trays |
MCP-220-00167-0B MCP-220-00127-0B |
1~4 |
Tool-less black hot-swap 2.5" NVMe drive tray (Orange tab, w/ key lock, clip design) Black hot-swap 2.5" NVMe drive tray (Orange tab, w/ key lock) |
2 Internal M.2 slots (1 SATA, 1 NVMe) | RSC-UMR-8 & CBL-SAST-0538 & MCP-120-82924-0N & MCP-310-21902-0N |
1 | 1U Ultra RHS Riser Card with 1 PCIE/SATA Hybrid M.2 &1 PCIE X8 |
2 Rear 2.5" Hot-swap SATA Drive Bays (Complete System Only) | MCP-240-82922-0N-OEM | - | Rear 2x 2.5" HDDs riser bracket kit for SC829U/219U, tool-less |
Storage Control Card and Cable(s) |
AOC-S3008L-L8e & 2x CBL-SAST-0593 AOC-S3008L-L8i & 2x CBL-SAST-0593 AOC-S3108L-H8iR & 2x CBL-SAST-0593 AOC-S3108L-H8iR-16DD & 2x CBL-SAST-0593 |
1~3 |
Std LP, 8 internal ports, 12Gb/s per port- Gen3, 122HDD, HBA; MINI SAS HD,12G,INT,60CM,30AWG Std LP, 8 internal ports, 12Gb/s per port- Gen3, 63HDD, RAID 0,1,1E; MINI SAS HD,12G,INT,60CM,30AWG Std LP, 8 internal ports, 12Gb/s per port- Gen3, 240HDD, RAID 0, 1, 5, 6, 10, 50, 60; MINI SAS HD,12G,INT,60CM,30AWG Std LP, 8 internal ports, 12Gb/s per port- Gen3, 16HDD, RAID 0, 1, 5, 6, 10, 50, 60; MINI SAS HD,12G,INT,60CM,30AWG |
Network Card(s) |
AOC-SGP-i2/4 AOC-STGN-i1S/i2S AOC-STGF-i2S AOC-STG-i4S AOC-STG-b4S AOC-STG-i2T AOC-STGS-i1/2T AOC-STG-i4T AOC-STG-i2 AOC-S25G-m2S AOC-S40G-i2Q More |
- - - - - - - - - - - - |
Standard LP, 2/4x GbE RJ45, PCI-E x4, Intel i350 Standard LP, 1/2x 10GbE SFP+, PCI-E x8, Intel 82599EN Standard LP, 2x 10GbE SFP+, PCI-E x8, Intel XL710-BM2 Standard LP, 4x 10GbE SFP+, PCI-E x8, Intel XL710 Standard LP, 4x 10GbE SFP+, PCI-E x8, Broadcom BCM57840S Standard LP, 2x 10GbE RJ45, PCI-E x8, Intel X540 Standard LP, 1/2x 10GbE RJ45, PCI-E x8, Intel X550 Standard LP, 4x 10GbE RJ45, PCI-E x8, Intel XL710 Standard LP, 2x 10GbE CX4, PCI-E x8, Intel 82598EB Standard LP, 2x 25GbE SFP28, Mellanox ConnectX-4 LX EN Standard LP 2-port 40GbE controller, Intel Fortville XL710 AOC Compatibility Matrix |
CacheVault(s) | BTR-CV3108-U1 | - | CacheVault for Broadcom 3108 with Supercap mounting for 2U Ultra |
TPM security module | AOM-TPM-9670H-S AOM-TPM-9671H-S |
1 1 |
TCG 2.0 compliant trusted platform module (TPM), Horizontal FF TCG 1.2 compliant trusted platform module (TPM), Horizontal FF |
Intel VROC RAID Key | AOC-VROCINTMOD AOC-VROCSTNMOD AOC-VROCPREMOD |
1 1 1 |
Intel VROC, RAID 0, 1, 5, 10 (Intel SSD Only) Intel VROC Standard, RAID 0, 1, 10 Intel VROC Premium, RAID 0, 1, 5, 10 |
Global Services & Support | OS4HR3/2/1 OSNBD3/2/1 |
- - |
3/2/1-year onsite 24x7x4 service 3/2/1-year onsite NBD service |
Software |
SFT-OOB-LIC OOB Management Package (per node license) consists of: • (X10 or Later Only) OOB System Checks such as Asset Information, System Utilization, Sensor Data • (X10 or Later Only) BIOS and BMC System Event Log management • BIOS Management functions such as in-band/OOB BIOS updates, provision BIOS config and DMI settings • BMC Management functions such as OOB BMC F/W updates and provisioning F/W settings • (X10 or Later Only) TPM provisioning • Scripting capabilities to mount virtual media Software tools: SUM ',ABOVE,ol_width=750,ol_border=1,ol_cellpad=6);" target="_blank">SFT-OOB-LIC • 1 |
OOB Management Package (per node license) | |
Software | SFT-DCMS-Single DataCenter Management Package (per node license) consists of: • OOB Management package capabilities provided by SFT-OOB-LIC • Centralized Management Console licenses for health monitoring, power management and firmware upgrades • RESTful API support to integrate server management into existing management infrastructure (roadmap Q1’15) • Advanced Power Management licenses to manage power on heterogeneous server vendor products • Remote Software installation support • Remote debug assistance directly from product engineers Software tools: SSM, SPM, SUM',ABOVE,ol_width=750,ol_border=1,ol_cellpad=6);">SFT-DCMS-Single |
1 | DataCenter Management Package (per node license) |