製品情報

1018R-WC0R

製品種別 サーバ
CPUソケット数
CPU  
 
 
 
筐体サイズ 1U
最大GPU数
電源仕様 リダンダント電源
用途/特長
製品説明

Supermicroについて


製品仕様

Product SKUs
SYS-1018R-WC0R SuperServer 1018R-WC0R (Black)
Processor
CPU Intel® Xeon® processor E5-2600 v4/v3, E5-1600 v4/v3 family(up to 145W TDP **)
Single Socket R3 (LGA 2011)
Core / Cache Up to 22 Cores / Up to 55MB Cache
Note BIOS version 2.0 or above is required
** Motherboard supports this maximum TDP. Please verify your system can thermally support
メモリ
Memory Capacity 8x 288-pin DDR4 DIMM slots
Up to 1TB ECC 3DS LRDIMM
Up to 512GB ECC LRDIMM
Up to 256GB ECC RDIMM
Memory Type 2400/2133/1866/1600MHz ECC DDR4 SDRAM 72-bit, 288-pin (RDIMM / LRDIMM) / 284-pin gold-plated DIMMs
DIMM Sizes 3DS LRDIMM: 128GB
LRDIMM: 64GB, 32GB
RDIMM: 32GB, 16GB, 8GB, 4GB
Memory Voltage 1.2 V
Error Detection Corrects single-bit errors
Detects double-bit errors (using ECC memory)
オンボードデバイス
Chipset Intel® C612 chipset
SATA SATA3 (6Gbps) via C612 controller
RAID 0, 1, 5, 10 support
IPMI Support for Intelligent Platform Management Interface v.2.0
IPMI 2.0 with virtual media over LAN and KVM-over-LAN support
ASPEED AST2400 BMC with 10/100/1000Mbps
Network Controllers Intel® i350-AM2 Dual Port Gigabit Ethernet
Virtual Machine Device Queues reduce I/O overhead
Supports 10BASE-T, 100BASE-TX, and 1000BASE-T, RJ45 output
VGA ASPEED AST2400 BMC
標準インターフェース
SATA 10x SATA3 (6Gbps) ports
SATA DOM Power Connector
LAN 2x RJ45 Gigabit Ethernet LAN ports
1x RJ45 Dedicated IPMI LAN port
USB 2x USB 3.0 ports (rear)
2x USB 2.0 ports (rear)
2x USB 3.0 ports (front)
VGA 1x VGA port
Serial Port / Header 2x COM ports (1 rear, 1 header)
DOM 2x SuperDOM (Disk on Module) ports
システム監視機能
Voltage Monitors for CPU Cores, +12V, +3.3V, +5V, +5V Standby, VBAT, HT, Memory, Chipset Voltages.
5-Phase-switching voltage regulator with auto-sense from 0.8375V-1.60V
FAN 6x 4-pin fan headers
6x fans w/ tachometer status monitoring
Status monitor for speed control
Status monitor for on/off control
Support 3-pin fans (w/o speed control)
Low noise fan speed control
Pulse Width Modulated (PWM) fan connectors
Temperature Monitoring for CPU & chassis environment
CPU thermal trip support
FC temperature sensing logic
Thermal Monitor 2 (TM2) support
PECI
LED System Information LED
+5V Standby alert LED
Other Features Chassis intrusion detection
Chassis intrusion header
Product SKUs
SYS-1018R-WC0R SuperServer 1018R-WC0R (Black)
Processor
CPU Intel® Xeon® processor E5-2600 v4/v3, E5-1600 v4/v3 family(up to 145W TDP **)
Single Socket R3 (LGA 2011)
Core / Cache Up to 22 Cores / Up to 55MB Cache
Note BIOS version 2.0 or above is required
** Motherboard supports this maximum TDP. Please verify your system can thermally support
メモリ
Memory Capacity 8x 288-pin DDR4 DIMM slots
Up to 1TB ECC 3DS LRDIMM
Up to 512GB ECC LRDIMM
Up to 256GB ECC RDIMM
Memory Type 2400/2133/1866/1600MHz ECC DDR4 SDRAM 72-bit, 288-pin (RDIMM / LRDIMM) / 284-pin gold-plated DIMMs
DIMM Sizes 3DS LRDIMM: 128GB
LRDIMM: 64GB, 32GB
RDIMM: 32GB, 16GB, 8GB, 4GB
Memory Voltage 1.2 V
Error Detection Corrects single-bit errors
Detects double-bit errors (using ECC memory)
オンボードデバイス
Chipset Intel® C612 chipset
SATA SATA3 (6Gbps) via C612 controller
RAID 0, 1, 5, 10 support
IPMI Support for Intelligent Platform Management Interface v.2.0
IPMI 2.0 with virtual media over LAN and KVM-over-LAN support
ASPEED AST2400 BMC with 10/100/1000Mbps
Network Controllers Intel® i350-AM2 Dual Port Gigabit Ethernet
Virtual Machine Device Queues reduce I/O overhead
Supports 10BASE-T, 100BASE-TX, and 1000BASE-T, RJ45 output
VGA ASPEED AST2400 BMC
標準インターフェース
SATA 10x SATA3 (6Gbps) ports
SATA DOM Power Connector
LAN 2x RJ45 Gigabit Ethernet LAN ports
1x RJ45 Dedicated IPMI LAN port
USB 2x USB 3.0 ports (rear)
2x USB 2.0 ports (rear)
2x USB 3.0 ports (front)
VGA 1x VGA port
Serial Port / Header 2x COM ports (1 rear, 1 header)
DOM 2x SuperDOM (Disk on Module) ports
システム監視機能
Voltage Monitors for CPU Cores, +12V, +3.3V, +5V, +5V Standby, VBAT, HT, Memory, Chipset Voltages.
5-Phase-switching voltage regulator with auto-sense from 0.8375V-1.60V
FAN 6x 4-pin fan headers
6x fans w/ tachometer status monitoring
Status monitor for speed control
Status monitor for on/off control
Support 3-pin fans (w/o speed control)
Low noise fan speed control
Pulse Width Modulated (PWM) fan connectors
Temperature Monitoring for CPU & chassis environment
CPU thermal trip support
FC temperature sensing logic
Thermal Monitor 2 (TM2) support
PECI
LED System Information LED
+5V Standby alert LED
Other Features Chassis intrusion detection
Chassis intrusion header
シャーシ
Form Factor 1U Rackmount
Model CSE-116AC-R706WB
外形寸法・重量
Height 1.7" (43mm)
Width 17.2" (437mm)
Depth 23.5" (597mm)
Package 8" (H) x 24" (W) x 32" (D)
Weight Gross Weight: 40 lbs (18.1 kg)
Net Weight: 25 lbs (11.3 kg)
Available Colors Black
フロントパネル
Buttons Power On/Off button
System Reset button
LEDs Power LED
Hard drive activity LED
2x Network activity LEDs
System Information LED
拡張スロット
PCI-Express 2x PCI-E 3.0 x16 Full-height Full-length slots
1x PCI-E 3.0 x8 (in x16) Half-height Half-length slot
ドライブベイ
Hot-swap 8x 2.5" Hot-swap SAS3/SATA3 HDD bays + 2x 2.5" Hot-swap SATA3 (total of 10)
冷却機構
Fans 4x 40x56mm 4-pin PWM Cooling Fans
1x Additional fan to cool add-on cards
AC/DC240V Input Redundant Power Supply
Total Output Power 700W/750W
Dimension
(W x H x L)
54.5 x 40.25 x 320 mm
Input 100 - 140Vac / 8 - 6A / 50-60Hz
200 - 240Vac / 4.5 - 3.8A / 50-60Hz
200 - 240Vdc / 4.5 - 3.8A (CCC Only)
+12V Max: 58A / Min: 0.5A (100 - 140Vac)
Max: 62A / Min: 0.5A (200 - 240Vac)
Max: 62A / Min: 0.5A (200 - 240Vdc)
(CB/CCC Only)
+5V sb Max: 3A / Min: 0A
Output Type Gold Finger Connector Mating with Molex 45984-4343
Certification
  Platinum Certified
  [ Test Report ]
BIOS
BIOS Type 64Mb SPI Flash EEPROM with AMI BIOS
BIOS Features Plug and Play (PnP)
APM 1.2
DMI 2.3
PCI 2.3
ACPI 1.0 / 2.0 / 3.0 / 4.0
USB Keyboard support
Hardware BIOS Virus protection
SMBIOS 2.7.1
UEFI 2.3.1
RTC (Real Time Clock) Wakeup
マネージメント
Software IPMI (Intelligent Platform Management Interface) v2.0 with KVM support
SuperDoctor® III
Watch Dog
NMI
Power Configurations ACPI / ACPM Power Management
Main Switch Override Mechanism
Power-on mode for AC power recovery
Internal/External modem ring-on
動作環境/コンプライアンス
RoHS
RoHS Compliant
Environmental Spec. Operating Temperature:
   10°C to 35°C (50°F to 95°F)
Non-operating Temperature:
   -40°C to 70°C (-40°F to 158°F)
Operating Relative Humidity:
   8% to 90% (non-condensing)
Non-operating Relative Humidity:
   5% to 95% (non-condensing)

パーツ仕様

パーツリスト
型番 数量 内容
Motherboard / Chassis MBD-X10SRW-F 1 Super X10SRW-F Motherboard
Motherboard / Chassis CSE-116AC2-R706WB 1 1U Chassis
Backplane BPN-SAS3-116A 1 10-port 1U SAS3 12Gbps direct-attached backplane, support up to 10x 2.5-inch SAS3/SATA3 HDD/SSD
Cable 1 CBL-SAST-0591 2 MINI SAS HD-4 SATA,6G,INT,RF,Cross Over,75CM,75CM SB,30AWG
Cable 2 CBL-0157L 1 CBL,SGPIO,2X4F TO 2X4F,P2.54,RIBBON IN RND TUBE,40CM,28AWG
Cable 3 CBL-0207L 2 SATA,INT,ROUND,ST-ST,59CM,26AWG
Label LBL-0108 1 CAUTION LABEL FOR REDUNDANT PWR SYSTEMS
Manual MNL-1608-QRG 1 SYS-1018R-WC0R, QRG,HF,RoHS/REACH
Riser Card RSC-R1UW-2E16 1 1U LHS WIO Riser card with two PCI-E x16 slots
Riser Card RSC-R1UW-E8R 1 1U RHS WIO Riser card with one PCI-E x8 slot
Heatsink / Retention SNK-P0047PS 1 1U Passive CPU Heat Sink for X9, X10 Systems Equipped w/ a Narrow ILM MB
Fan FAN-0101L4 1 40x40x56mm 14.4K-10.7K RPM Counter-rotating Fan
Power Supply PWS-706P-1R 2 1U 750W redundant power width 54.5mm(Platinum),HF,RoHS/REACH,PBF
オプションパーツリスト
型番 数量 内容
Storage Control Card and Cable(s) AOC-S3008L-L8e & 2x CBL-SAST-0593 AOC-S3008L-L8i & 2x CB - Std LP, 8 internal ports, 12Gb/s per port- Gen3, 122HDD, HBA; Internal Mini-SAS HD to Mini-SAS HD 60cm,30AWG,12Gb/s Std LP, 8 internal ports, 12Gb/s per port- Gen3, 63HDD, RAID 0,1,1E; Internal Mini-SAS HD to Mini-SAS HD 60cm,30AWG,12Gb/s Std LP, 8 internal ports, 12Gb/s per port- Gen3, 240HDD, RAID 0, 1, 5, 6, 10, 50, 60; Internal Mini-SAS HD to Mini-SAS HD 60cm,30AWG,12Gb/s
Cable 1 CBL-SAST-0590 - Internal Mini-SAS HD to Mini-SAS HD for PCIe SSD, Internal Mini-SAS HD cablefor PCIe SSD NVMe, 12Gb/s, 70cm,30AWG
Cable 2 CBL-SAST-0508-01 - Internal Mini-SAS to Mini-SAS HD 50cm w/ SB, 30AWG,HF,RoHS/REACH,PBF
Cable 3 CBL-SAST-0532 - Internal Mini-SAS HD to Mini-SAS HD 50cm,30AWG,12Gb/s,HF,RoHS/REACH,PBF
Cable 4 CBL-SAST-0568 - Internal Mini-SAS HD to Mini-SAS HD 35cm,30AWG,12Gb/s,HF,RoHS/REACH,PBF
パーツリスト
型番 数量 内容
Motherboard / Chassis CSE-116AC-R706WB 1 1U Chassis
オプションパーツリスト
型番 数量 内容
Storage Controller card & cable AOC-S3108L-H8iR & 2x CBL-SAST-0593 Standard LP, 8 Internal ports (12Gb/s) PCI-E 3.0 x8, RAID controller, RAID 0, 1, 5, 6, 10, 50, 60
Front Bezels MCP-210-11601-0B 1 Black front bezels
TPM security module AOM-TPM-9665V 1 TPM 2.0, vertical form factor
TPM security module AOM-TPM-9655V 1 TPM 1.2, vertical form factor
Global Services & Support OS4HR3/2/1 1 3/2/1-year onsite 24x7x4 service
Global Services & Support OSNBD3/2/1 1 3/2/1-year onsite NBD service
Software SFT-OOB-LIC • 1 OOB Management Package (per node license)
Software SFT-DCMS-Single 1 DataCenter Management Package (per node license)