1018R-WC0R
製品種別 | サーバ |
---|---|
CPUソケット数 | |
CPU | |
筐体サイズ | 1U |
最大GPU数 | |
電源仕様 | リダンダント電源 |
用途/特長 | |
製品説明 |
製品仕様
Product SKUs | SYS-1018R-WC0R | SuperServer 1018R-WC0R (Black) |
---|---|
Processor | CPU | Intel® Xeon® processor E5-2600 v4†/v3, E5-1600 v4†/v3 family(up to 145W TDP **) Single Socket R3 (LGA 2011) |
Core / Cache | Up to 22 Cores† / Up to 55MB† Cache |
Note | † BIOS version 2.0 or above is required ** Motherboard supports this maximum TDP. Please verify your system can thermally support |
メモリ | Memory Capacity | 8x 288-pin DDR4 DIMM slots Up to 1TB ECC 3DS LRDIMM Up to 512GB ECC LRDIMM Up to 256GB ECC RDIMM |
Memory Type | 2400†/2133/1866/1600MHz ECC DDR4 SDRAM 72-bit, 288-pin (RDIMM / LRDIMM) / 284-pin gold-plated DIMMs |
DIMM Sizes | 3DS LRDIMM: 128GB LRDIMM: 64GB, 32GB RDIMM: 32GB, 16GB, 8GB, 4GB |
Memory Voltage | 1.2 V |
Error Detection | Corrects single-bit errors Detects double-bit errors (using ECC memory) |
オンボードデバイス | Chipset | Intel® C612 chipset |
SATA | SATA3 (6Gbps) via C612 controller RAID 0, 1, 5, 10 support |
IPMI | Support for Intelligent Platform Management Interface v.2.0 IPMI 2.0 with virtual media over LAN and KVM-over-LAN support ASPEED AST2400 BMC with 10/100/1000Mbps |
Network Controllers | Intel® i350-AM2 Dual Port Gigabit Ethernet Virtual Machine Device Queues reduce I/O overhead Supports 10BASE-T, 100BASE-TX, and 1000BASE-T, RJ45 output |
VGA | ASPEED AST2400 BMC |
標準インターフェース | SATA | 10x SATA3 (6Gbps) ports SATA DOM Power Connector |
LAN | 2x RJ45 Gigabit Ethernet LAN ports 1x RJ45 Dedicated IPMI LAN port |
USB | 2x USB 3.0 ports (rear) 2x USB 2.0 ports (rear) 2x USB 3.0 ports (front) |
VGA | 1x VGA port |
Serial Port / Header | 2x COM ports (1 rear, 1 header) |
DOM | 2x SuperDOM (Disk on Module) ports |
システム監視機能 | Voltage | Monitors for CPU Cores, +12V, +3.3V, +5V, +5V Standby, VBAT, HT, Memory, Chipset Voltages. 5-Phase-switching voltage regulator with auto-sense from 0.8375V-1.60V |
FAN | 6x 4-pin fan headers 6x fans w/ tachometer status monitoring Status monitor for speed control Status monitor for on/off control Support 3-pin fans (w/o speed control) Low noise fan speed control Pulse Width Modulated (PWM) fan connectors |
Temperature | Monitoring for CPU & chassis environment CPU thermal trip support FC temperature sensing logic Thermal Monitor 2 (TM2) support PECI |
LED | System Information LED +5V Standby alert LED |
Other Features | Chassis intrusion detection Chassis intrusion header |
Product SKUs | SYS-1018R-WC0R | SuperServer 1018R-WC0R (Black) |
Processor | CPU | Intel® Xeon® processor E5-2600 v4†/v3, E5-1600 v4†/v3 family(up to 145W TDP **) Single Socket R3 (LGA 2011) |
Core / Cache | Up to 22 Cores† / Up to 55MB† Cache |
Note | † BIOS version 2.0 or above is required ** Motherboard supports this maximum TDP. Please verify your system can thermally support |
メモリ | Memory Capacity | 8x 288-pin DDR4 DIMM slots Up to 1TB ECC 3DS LRDIMM Up to 512GB ECC LRDIMM Up to 256GB ECC RDIMM |
Memory Type | 2400†/2133/1866/1600MHz ECC DDR4 SDRAM 72-bit, 288-pin (RDIMM / LRDIMM) / 284-pin gold-plated DIMMs |
DIMM Sizes | 3DS LRDIMM: 128GB LRDIMM: 64GB, 32GB RDIMM: 32GB, 16GB, 8GB, 4GB |
Memory Voltage | 1.2 V |
Error Detection | Corrects single-bit errors Detects double-bit errors (using ECC memory) |
オンボードデバイス | Chipset | Intel® C612 chipset |
SATA | SATA3 (6Gbps) via C612 controller RAID 0, 1, 5, 10 support |
IPMI | Support for Intelligent Platform Management Interface v.2.0 IPMI 2.0 with virtual media over LAN and KVM-over-LAN support ASPEED AST2400 BMC with 10/100/1000Mbps |
Network Controllers | Intel® i350-AM2 Dual Port Gigabit Ethernet Virtual Machine Device Queues reduce I/O overhead Supports 10BASE-T, 100BASE-TX, and 1000BASE-T, RJ45 output |
VGA | ASPEED AST2400 BMC |
標準インターフェース | SATA | 10x SATA3 (6Gbps) ports SATA DOM Power Connector |
LAN | 2x RJ45 Gigabit Ethernet LAN ports 1x RJ45 Dedicated IPMI LAN port |
USB | 2x USB 3.0 ports (rear) 2x USB 2.0 ports (rear) 2x USB 3.0 ports (front) |
VGA | 1x VGA port |
Serial Port / Header | 2x COM ports (1 rear, 1 header) |
DOM | 2x SuperDOM (Disk on Module) ports |
システム監視機能 | Voltage | Monitors for CPU Cores, +12V, +3.3V, +5V, +5V Standby, VBAT, HT, Memory, Chipset Voltages. 5-Phase-switching voltage regulator with auto-sense from 0.8375V-1.60V |
FAN | 6x 4-pin fan headers 6x fans w/ tachometer status monitoring Status monitor for speed control Status monitor for on/off control Support 3-pin fans (w/o speed control) Low noise fan speed control Pulse Width Modulated (PWM) fan connectors |
Temperature | Monitoring for CPU & chassis environment CPU thermal trip support FC temperature sensing logic Thermal Monitor 2 (TM2) support PECI |
LED | System Information LED +5V Standby alert LED |
Other Features | Chassis intrusion detection Chassis intrusion header |
シャーシ | Form Factor | 1U Rackmount |
Model | CSE-116AC-R706WB |
外形寸法・重量 | Height | 1.7" (43mm) |
Width | 17.2" (437mm) |
Depth | 23.5" (597mm) |
Package | 8" (H) x 24" (W) x 32" (D) |
Weight | Gross Weight: 40 lbs (18.1 kg) Net Weight: 25 lbs (11.3 kg) |
Available Colors | Black |
フロントパネル | Buttons | Power On/Off button System Reset button |
LEDs | Power LED Hard drive activity LED 2x Network activity LEDs System Information LED |
拡張スロット | PCI-Express | 2x PCI-E 3.0 x16 Full-height Full-length slots 1x PCI-E 3.0 x8 (in x16) Half-height Half-length slot |
ドライブベイ | Hot-swap | 8x 2.5" Hot-swap SAS3/SATA3 HDD bays + 2x 2.5" Hot-swap SATA3 (total of 10) |
冷却機構 | Fans | 4x 40x56mm 4-pin PWM Cooling Fans 1x Additional fan to cool add-on cards |
AC/DC240V Input Redundant Power Supply | Total Output Power | 700W/750W |
Dimension(W x H x L) | 54.5 x 40.25 x 320 mm |
Input | 100 - 140Vac / 8 - 6A / 50-60Hz 200 - 240Vac / 4.5 - 3.8A / 50-60Hz 200 - 240Vdc / 4.5 - 3.8A (CCC Only) |
+12V | Max: 58A / Min: 0.5A (100 - 140Vac) Max: 62A / Min: 0.5A (200 - 240Vac) Max: 62A / Min: 0.5A (200 - 240Vdc)(CB/CCC Only) |
+5V sb | Max: 3A / Min: 0A |
Output Type | Gold Finger Connector Mating with Molex 45984-4343 |
Certification | Platinum Certified [ Test Report ] |
BIOS | BIOS Type | 64Mb SPI Flash EEPROM with AMI BIOS |
BIOS Features | Plug and Play (PnP) APM 1.2 DMI 2.3 PCI 2.3 ACPI 1.0 / 2.0 / 3.0 / 4.0 USB Keyboard support Hardware BIOS Virus protection SMBIOS 2.7.1 UEFI 2.3.1 RTC (Real Time Clock) Wakeup |
マネージメント | Software | IPMI (Intelligent Platform Management Interface) v2.0 with KVM support SuperDoctor® III Watch Dog NMI |
Power Configurations | ACPI / ACPM Power Management Main Switch Override Mechanism Power-on mode for AC power recovery Internal/External modem ring-on |
動作環境/コンプライアンス | RoHS | RoHS Compliant |
Environmental Spec. | Operating Temperature: 10°C to 35°C (50°F to 95°F) Non-operating Temperature: -40°C to 70°C (-40°F to 158°F) Operating Relative Humidity: 8% to 90% (non-condensing) Non-operating Relative Humidity: 5% to 95% (non-condensing) |
パーツ仕様
パーツリスト | |||
---|---|---|---|
型番 | 数量 | 内容 | |
Motherboard / Chassis | MBD-X10SRW-F | 1 | Super X10SRW-F Motherboard |
Motherboard / Chassis | CSE-116AC2-R706WB | 1 | 1U Chassis |
Backplane | BPN-SAS3-116A | 1 | 10-port 1U SAS3 12Gbps direct-attached backplane, support up to 10x 2.5-inch SAS3/SATA3 HDD/SSD |
Cable 1 | CBL-SAST-0591 | 2 | MINI SAS HD-4 SATA,6G,INT,RF,Cross Over,75CM,75CM SB,30AWG |
Cable 2 | CBL-0157L | 1 | CBL,SGPIO,2X4F TO 2X4F,P2.54,RIBBON IN RND TUBE,40CM,28AWG |
Cable 3 | CBL-0207L | 2 | SATA,INT,ROUND,ST-ST,59CM,26AWG |
Label | LBL-0108 | 1 | CAUTION LABEL FOR REDUNDANT PWR SYSTEMS |
Manual | MNL-1608-QRG | 1 | SYS-1018R-WC0R, QRG,HF,RoHS/REACH |
Riser Card | RSC-R1UW-2E16 | 1 | 1U LHS WIO Riser card with two PCI-E x16 slots |
Riser Card | RSC-R1UW-E8R | 1 | 1U RHS WIO Riser card with one PCI-E x8 slot |
Heatsink / Retention | SNK-P0047PS | 1 | 1U Passive CPU Heat Sink for X9, X10 Systems Equipped w/ a Narrow ILM MB |
Fan | FAN-0101L4 | 1 | 40x40x56mm 14.4K-10.7K RPM Counter-rotating Fan |
Power Supply | PWS-706P-1R | 2 | 1U 750W redundant power width 54.5mm(Platinum),HF,RoHS/REACH,PBF |
オプションパーツリスト | |||
型番 | 数量 | 内容 | |
Storage Control Card and Cable(s) | AOC-S3008L-L8e & 2x CBL-SAST-0593 AOC-S3008L-L8i & 2x CB | - | Std LP, 8 internal ports, 12Gb/s per port- Gen3, 122HDD, HBA; Internal Mini-SAS HD to Mini-SAS HD 60cm,30AWG,12Gb/s Std LP, 8 internal ports, 12Gb/s per port- Gen3, 63HDD, RAID 0,1,1E; Internal Mini-SAS HD to Mini-SAS HD 60cm,30AWG,12Gb/s Std LP, 8 internal ports, 12Gb/s per port- Gen3, 240HDD, RAID 0, 1, 5, 6, 10, 50, 60; Internal Mini-SAS HD to Mini-SAS HD 60cm,30AWG,12Gb/s |
Cable 1 | CBL-SAST-0590 | - | Internal Mini-SAS HD to Mini-SAS HD for PCIe SSD, Internal Mini-SAS HD cablefor PCIe SSD NVMe, 12Gb/s, 70cm,30AWG |
Cable 2 | CBL-SAST-0508-01 | - | Internal Mini-SAS to Mini-SAS HD 50cm w/ SB, 30AWG,HF,RoHS/REACH,PBF |
Cable 3 | CBL-SAST-0532 | - | Internal Mini-SAS HD to Mini-SAS HD 50cm,30AWG,12Gb/s,HF,RoHS/REACH,PBF |
Cable 4 | CBL-SAST-0568 | - | Internal Mini-SAS HD to Mini-SAS HD 35cm,30AWG,12Gb/s,HF,RoHS/REACH,PBF |
パーツリスト | |||
型番 | 数量 | 内容 | |
Motherboard / Chassis | CSE-116AC-R706WB | 1 | 1U Chassis |
オプションパーツリスト | |||
型番 | 数量 | 内容 | |
Storage Controller card & cable | AOC-S3108L-H8iR & 2x CBL-SAST-0593 | Standard LP, 8 Internal ports (12Gb/s) PCI-E 3.0 x8, RAID controller, RAID 0, 1, 5, 6, 10, 50, 60 | |
Front Bezels | MCP-210-11601-0B | 1 | Black front bezels |
TPM security module | AOM-TPM-9665V | 1 | TPM 2.0, vertical form factor |
TPM security module | AOM-TPM-9655V | 1 | TPM 1.2, vertical form factor |
Global Services & Support | OS4HR3/2/1 | 1 | 3/2/1-year onsite 24x7x4 service |
Global Services & Support | OSNBD3/2/1 | 1 | 3/2/1-year onsite NBD service |
Software | SFT-OOB-LIC • | 1 | OOB Management Package (per node license) |
Software | SFT-DCMS-Single | 1 | DataCenter Management Package (per node license) |