1028R-WTNR
製品種別 | サーバ |
---|---|
CPUソケット数 | |
CPU | |
筐体サイズ | 1U |
最大GPU数 | |
電源仕様 | リダンダント電源 |
用途/特長 | |
製品説明 |
製品仕様
Product SKUs | SYS-1028R-WTNR | SuperServer 1028R-WTNR (Black) |
---|---|
プロセッサ/キャッシュ | CPU | Intel® Xeon® processor E5-2600 v4†/v3 family(up to 145W TDP)* Dual Socket R3 (LGA 2011) |
Cores / Cache | Up to 22 Cores† / Up to 55MB† Cache |
System Bus | QPI up to 9.6 GT/s |
Note | † BIOS version 2.0 or above is required * Please contact Supermicro Technical Support for additional information about frequency optimized CPUs and specialized system optimization. |
メモリ | Memory Capacity | 16x 288-pin DDR4 DIMM slots Up to 2TB† ECC 3DS LRDIMM, 512GB ECC RDIMM |
Memory Type | 2400†/2133/1866/1600MHz ECC DDR4 SDRAM 72-bit |
DIMM Sizes | RDIMM:64GB, 32GB, 16GB, 8GB, 4GB LRDIMM: 64GB, 32GB 3DS LRDIMM: 128GB |
Memory Voltage | 1.2 V |
Error Detection | Corrects single-bit errors |
オンボードデバイス | Chipset | Intel® C612 chipset |
SATA | SATA3 (6Gbps); RAID 0, 1, 5, 10 |
IPMI | Support for Intelligent Platform Management Interface v.2.0 IPMI 2.0 with virtual media over LAN and KVM-over-LAN support ASPEED AST2400 BMC |
Network Controllers | Intel® i350 Dual Port Gigabit Ethernet Controller Virtual Machine Device Queues reduce I/O overhead Supports 10BASE-T, 100BASE-TX, and 1000BASE-T, RJ45 output 1x Realtek RTL8211E PHY (dedicated IPMI) |
Video | ASPEED AST2400 BMC |
標準インターフェース | Serial ATA | 8 SATA3 (6 Gbps) ports and 2 NVMe/SATA3 hybrid ports |
LAN | 2x RJ45 Gigabit Ethernet LAN ports 1x RJ45 Dedicated IPMI LAN port |
USB | 2x USB 3.0 ports (front via header) 4x USB 2.0 ports (rear) |
Video | 1x VGA port |
Serial Port / Header | 1x Fast UART 16550 header |
DOM | 2x SuperDOM (Disk on Module) ports |
システム監視機能 | Voltage | Monitors for CPU Cores, +1.8V, +3.3V, +5V, +12V, +3.3V Standby, +5V Standby, VBAT, Memory Voltages. 5+1 Phase-switching voltage regulator |
FAN | 6x 4-pin fan headers (up to 6 fans) 6x fans with tachometer monitoring Status monitor for speed control Pulse Width Modulated (PWM) fan connectors |
Temperature | Monitoring for CPU and chassis environment CPU thermal trip support Thermal Control for 8x Fan Connectors Thermal Monitor 2 (TM2) support PECI |
LED | System Information LED Suspend static indicator LED UID/Remote UID |
Other Features | Chassis intrusion detection Chassis intrusion header SDDC Support RoHS |
Product SKUs | SYS-1028R-WTNR | SuperServer 1028R-WTNR (Black) |
プロセッサ/キャッシュ | CPU | Intel® Xeon® processor E5-2600 v4†/v3 family(up to 145W TDP)* Dual Socket R3 (LGA 2011) |
Cores / Cache | Up to 22 Cores† / Up to 55MB† Cache |
System Bus | QPI up to 9.6 GT/s |
Note | † BIOS version 2.0 or above is required * Please contact Supermicro Technical Support for additional information about frequency optimized CPUs and specialized system optimization. |
メモリ | Memory Capacity | 16x 288-pin DDR4 DIMM slots Up to 2TB† ECC 3DS LRDIMM, 512GB ECC RDIMM |
Memory Type | 2400†/2133/1866/1600MHz ECC DDR4 SDRAM 72-bit |
DIMM Sizes | RDIMM:64GB, 32GB, 16GB, 8GB, 4GB LRDIMM: 64GB, 32GB 3DS LRDIMM: 128GB |
Memory Voltage | 1.2 V |
Error Detection | Corrects single-bit errors |
オンボードデバイス | Chipset | Intel® C612 chipset |
SATA | SATA3 (6Gbps); RAID 0, 1, 5, 10 |
IPMI | Support for Intelligent Platform Management Interface v.2.0 IPMI 2.0 with virtual media over LAN and KVM-over-LAN support ASPEED AST2400 BMC |
Network Controllers | Intel® i350 Dual Port Gigabit Ethernet Controller Virtual Machine Device Queues reduce I/O overhead Supports 10BASE-T, 100BASE-TX, and 1000BASE-T, RJ45 output 1x Realtek RTL8211E PHY (dedicated IPMI) |
Video | ASPEED AST2400 BMC |
標準インターフェース | Serial ATA | 8 SATA3 (6 Gbps) ports and 2 NVMe/SATA3 hybrid ports |
LAN | 2x RJ45 Gigabit Ethernet LAN ports 1x RJ45 Dedicated IPMI LAN port |
USB | 2x USB 3.0 ports (front via header) 4x USB 2.0 ports (rear) |
Video | 1x VGA port |
Serial Port / Header | 1x Fast UART 16550 header |
DOM | 2x SuperDOM (Disk on Module) ports |
システム監視機能 | Voltage | Monitors for CPU Cores, +1.8V, +3.3V, +5V, +12V, +3.3V Standby, +5V Standby, VBAT, Memory Voltages. 5+1 Phase-switching voltage regulator |
FAN | 6x 4-pin fan headers (up to 6 fans) 6x fans with tachometer monitoring Status monitor for speed control Pulse Width Modulated (PWM) fan connectors |
Temperature | Monitoring for CPU and chassis environment CPU thermal trip support Thermal Control for 8x Fan Connectors Thermal Monitor 2 (TM2) support PECI |
LED | System Information LED Suspend static indicator LED UID/Remote UID |
Other Features | Chassis intrusion detection Chassis intrusion header SDDC Support RoHS |
シャーシ | Form Factor | 1U Rackmount |
Model | CSE-116AC2-R706WB |
外形寸法・重量 | Width | 17.2" (437mm) |
Height | 1.7" (43mm) |
Depth | 23.5" (597mm) |
Gross Weight | 46 lbs (20.9kg) |
Available Colors | Black |
フロントパネル | Buttons | Power On/Off button UID button |
LEDs | Power status LED HDD activity LED 2x Network activity LEDs Universal Information (UID) LED |
拡張スロット | PCI-Express | 2x PCI-E 3.0 x16 full-height, half-length slots |
ドライブベイ | Hot-swap | 8x SATA3 (6Gbps) ports and 2x NVMe/SATA3 hybrid ports (connected to onboard storage controller) |
冷却機構 | Fans | 5x 4cm heavy-duty counter-rotating fans w/ air shroud and optimal fan speed control |
AC/DC240V Input Redundant Power Supply | Total Output Power | 700W/750W |
Dimension(W x H x L) | 54.5 x 40.25 x 320 mm |
Input | 100 - 140Vac / 8 - 6A / 50-60Hz 200 - 240Vac / 4.5 - 3.8A / 50-60Hz 200 - 240Vdc / 4.5 - 3.8A (CCC Only) |
+12V | Max: 58A / Min: 0.5A (100 - 140Vac) Max: 62A / Min: 0.5A (200 - 240Vac) Max: 62A / Min: 0.5A (200 - 240Vdc)(CB/CCC Only) |
+5V sb | Max: 3A / Min: 0A |
Output Type | Gold Finger Connector Mating with Molex 45984-4343 |
Certification | Platinum Certified [ Test Report ] |
BIOS | BIOS Type | 128Mb SPI Flash EEPROM with AMI BIOS |
BIOS Features | Plug and Play (PnP) APM 1.2 PCI 2.3 ACPI 1.0 / 2.0 / 3.0 / 4.0 USB Keyboard support SMBIOS 2.7.1 UEFI 2.3.1 |
マネージメント | Software | SuperDoctor® 5 Watch Dog NMI IPMI 2.0 Intel Node Manager |
Power Configurations | ACPI / APM Power Management Power-on mode for AC power recovery |
動作環境/コンプライアンス | RoHS | RoHS Compliant |
Environmental Spec. | Operating Temperature: 10°C to 35°C (50°F to 95°F) Non-operating Temperature: -40°C to 70°C (-40°F to 158°F) Operating Relative Humidity: 8% to 90% (non-condensing) Non-operating Relative Humidity: 5% to 95% (non-condensing) |
パーツ仕様
パーツリスト | |||
---|---|---|---|
型番 | 数量 | 内容 | |
Motherboard / Chassis | MBD-X10DRW-N | 1 | Super X10DRW-N Motherboard |
Motherboard / Chassis | CSE-116AC2-R706WB | 1 | 1U Chassis |
Backplane | BPN-SAS3-116A-N2 | 1 | 10-Port 1U Backplane for 8x2.5\" SAS3/SATA3 HDD/SSD and 2xSAS2/SATA3 HDD/SSD or NVMe SSD |
Cable 1 | CBL-CDAT-0662 | 1 | 8 pin to 8 pin round SGPIO cable, 61.5cm, 28AWG, pinout 1-1,RoHS/REACH |
Cable 2 | CBL-SAST-0590 | 2 | Internal Mini-SAS HD to Mini-SAS HD for PCIe SSD, Internal Mini-SAS HD cablefor PCIe SSD NVMe, 12Gb/s, 70cm,30AWG |
Cable 3 | CBL-0484L | 2 | 55cm 30AWG SATA S-S cable |
Cable 4 | CBL-SAST-0631 | 2 | cross-over mini SAS HD to 4 SATA w/SB, S. 55cm. 30AWG,RoHS/REACH |
Label | LBL-0108 | 1 | CAUTION LABEL FOR REDUNDANT PWR SYSTEMS |
Manual | MNL-1724-QRG | 1 | QRG for 1028R-WTNR(T),HF |
Riser Card | RSC-R1UW-2E16 | 1 | RSC-R1UW-2E16-O-P |
Heatsink / Retention | SNK-P0047PSC | 1 | 1U Passive Front CPU Heat Sink w/ a Side Air Channel for X9, X10 Systems Equipped with a Narrow ILM MB |
Heatsink / Retention | SNK-P0057PS | 1 | 1U High Performance Passive CPU Heat Sink for X9, X10 Systems Equipped w/ a Narrow ILM MB |
Power Supply | PWS-706P-1R | 2 | 1U 750W redundant power width 54.5mm(Platinum),HF,RoHS/REACH,PBF |
Fan | FAN-0101L4 | 5 | 40x56, 4 Pin PWM |
Rail Set | MCP-290-00063-0N | 1 | Rail set, quick/quick, for 1U 17.2"W SC113 (Note: this is additional set to the default set included w/ Chassis) |
オプションパーツリスト | |||
型番 | 数量 | 内容 | |
Cable for Storage Controller Card Connection | CBL-0343L-01 | 1 | IPASS to 4 SATA Cable, 30AWG 76/66/54/45CM, W/ 66CM |
CachVault(s) | BTR-CV3108-1U1 | 1 | LSI 3108 CacheVault 1U dummy fan kit |
CacheVault Installation Kits | MCP-240-00127-0N BKT-BBU-BRACKET-05 | - | SuperCap installation kit for thick 2.5" HDD location SuperCap installation kit for PCI-E location |
BBU for 2208 | BTR-0022L-LSI00279 | - | LSI00279 IBBU09 BATTERY BACKUP FOR SAS2208 |
Cable | CBL-SAST-0531 | - | Internal Mini-SAS HD to Mini-SAS HD 80cm, 30AWG, 12Gb/s, HF, RoHS/REACH, PBF |
Cable | CBL-0388L-01 | - | IPASS TO 4 SATA 75/75/90/90CM W/ 75cm SB. RA. 30AWG for 2208, 2108, 2008, SAS2 cards |
Network Card(s) | AOC-SGP-i2 | - | Standard LP, 2x GbE RJ45, PCI-E x4, Intel®i350AM2 |
Network Card(s) | AOC-SGP-i4 | - | Standard LP, 4x GbE RJ45, PCI-E x4, Intel®i350 |
Network Card(s) | AOC-SG-i2 | - | Standard LP, 2x GbE RJ45, PCI-E x4, Intel®82575EB |
Network Card(s) | AOC-SG-i4 | - | Standard LP, 4x GbE RJ45, PCI-E x4, Intel®82576EB |
Network Card(s) | AOC-STG-b4S | - | Standard LP, 4x 10GbE SFP+, PCI-E x8, Broadcom®BCM57840S |
Network Card(s) | AOC-STGN-i2S | - | Standard LP, 2x 10GbE SFP+, PCI-E x8, Intel®82599ES |
Network Card(s) | AOC-STG-i2T | - | Standard LP, 2x 10GbE RJ45, PCI-E x8, Intel®X540 |
Network Card(s) | AOC-STG-i2 | - | Standard LP, 2x 10GbE CX4, PCI-E x8, Intel®82598EB |
Storage Controller Card(s) | AOC-S3008L-L8e | - | Standard LP, 8 internal ports (12Gb/s) Gen-3, 122HDD, HBA |
Storage Controller Card(s) | AOC-S3008L-L8i | - | Standard LP, 8 internal ports (12Gb/s) Gen-3, 63HDD, RAID 0,1,1E |
Storage Controller Card(s) | AOC-S3108L-H8iR | - | Standard LP, 8 internal ports (12Gb/s) Gen-3, 240HDD, RAID 0, 1, 5, 6, 10, 50, 60 |
Storage Controller Card(s) | AOC-S2308L-L8e | - | Standard LP, 8 internal ports (6Gb/s) Gen-3, 122HDD, HBA |
Storage Controller Card(s) | AOC-S2308L-L8i | - | Standard LP, 8 internal ports (6Gb/s) Gen-3, 63HDD, RAID 0,1,1E |
Storage Controller Card(s) | AOC-S2208L-H8iR | - | Standard LP, 8 internal ports (6Gb/s) Gen-3, 240HDD, RAID 0, 1, 5, 6, 10, 50, 60 |
Storage Controller Card(s) | AOC-SAS2LP-MV8 | - | Standard LP, 8 internal ports (6Gb/s) Gen-2, HBA |
Storage Controller Card(s) | AOC-SAS2LP-H4iR | - | Standard LP, 4 internal & 4 external ports (6Gb/s) Gen-2, 240HDD, RAID 0, 1, 5, 6, 10, 50, 60 |
Storage Controller Card(s) | AOC-SAS2LP-H8iR | - | Standard LP, 8 internal ports (6Gb/s) Gen-2, 240HDD, RAID 0, 1, 5, 6, 10, 50, 60 |
Onsite Service Program | OS4HR3/2/1 | - | 3/2/1-year onsite 24x7x4 service |
Onsite Service Program | OSNBD3/2/1 | - | 3/2/1-year onsite NBD service |
Software | SFT-OOB-LIC | 1 | OOB Management Package (per node license) |
Software | SFT-DCMS-Single | 1 | DataCenter Management Package (per node license) |