製品情報

H262-PC0 (rev. 100)

製品種別 サーバ
CPUソケット数 2
CPU  
筐体サイズ
最大GPU数
電源仕様 リダンダント電源
用途/特長   
製品説明

第3世代 Intel Xeon Scalable プロセッサーについて


製品仕様

Dimensions (WxHxD, mm) 2U 4 Nodes - Rear access
440 x 87 x 840
Motherboard MH62-HD0
CPU 3rd Generation Intel® Xeon® Scalable Processors
Intel® Xeon® Platinum Processor, Intel® Xeon® Gold Processor, Intel® Xeon® Silver Processor
10nm technology, CPU TDP up to 270W
NOTE: If only 1 CPU is installed, some PCIe or memory functions might be unavailable
Socket Per Node:
2 x LGA 4189
Total:
8 x LGA 4189
Socket P+
Chipset Intel® C621A Express Chipset
Memory Per node:
16 x DIMM slots

Total:
64 x DIMM slots
DDR4 memory supported only
8-channel memory architecture
RDIMM modules up to 64GB supported
LRDIMM modules up to 128GB supported
3DS RDIMM/LRDIMM modules up to 256GB supported
1.2V modules: 3200/2933/2666 MHz
LAN Per node:
2 x 10GbE BASE-T LAN ports (1 x Intel® X710-AT2)
1 x Dedicated management port

Total:
8 x 10GbE BASE-T LAN ports (1 x Intel® X710-AT2)
4 x Dedicated management port

* CMC: Chassis Management Controller, to monitor all status of computing nodes
Video Integrated in Aspeed® AST2500
2D Video Graphic Adapter with PCIe bus interface
1920x1200@60Hz 32bpp, DDR4 SDRAM

Management chip on CMC board:
Integrated in Aspeed® AST2520A2-GP
Audio N/A
Storage Per node:
2 x SATA/SAS/NVMe hot-swappable bays
1 x SATA DOM

Total:
8 x SATA/SAS/NVMe hot-swappable bays
4 x SATA DOM
SAS N/A
RAID For SATA drives:
Intel® SATA RAID 0/1
For NVMe drives:
Intel® Virtual RAID On CPU (VROC) RAID 0, 1
Note:
1) VROC module is compatible for Intel®SSD only
2) Default 1 PCS VROC module for one 2U 4 Nodes server system
Peripheral Drives N/A
Expansion Slots Per node:
Riser Card CRSH010:
- 1 x Half-length low-profile slot with PCIe x16 (Gen4 x16 bus)

Riser Card CRSH011:
- 1 x Half-length low-profile slots with PCIe x8 (Gen4 x8 bus)

1 x OCP mezzanine slot with PCIe Gen3 x16 bus

Total:
4 x Half-length low-profile slots with PCIe x16 (Gen4 x16 bus)
4 x Half-length low-profile slots with PCIe x8 (Gen4 x8 bus)
4 x OCP mezzanine slots with PCIe Gen3 x16 bus
Internal I/O Per node:
1 x COM header
1 x SATA 7-pin connectors
1 x TPM header
1 x BMC SGPIO header
1 x JTAG BMC header
1 x PLD header
1 x Clear CMOS jumper
1 x IPMB connector
1 x Buzzer
Front I/O Per node:
1 x Power button with LED
1 x ID button with LED
1 x Status LED
1 x Reset button

Total:
4 x Power button with LED
4 x ID button with LED
4 x Status LED
4 x Reset button

*1 x CMC Status LED
*1 x CMC Reset button

*Only one CMC Status LED and Reset button per system
Rear I/O Per node:
2 x USB 3.0
1 x VGA
1 x RJ45 MLAN
1 x ID LED

Total:
8 x USB 3.0
4 x VGA
4 x RJ45 MLAN
4 x ID LEDs
*1 x CMC global management port

*Only one CMC global management port per system
Backplane I/O 8 x ports
PCIe Gen4 x4 U.2 per port
TPM 1 x TPM header with SPI interface
Optional TPM2.0 kit: CTM010
Power Supply 2 x 2200W redundant PSUs
80 PLUS Platinum

AC Input:
- 100-127V~/ 14A, 47-63Hz
- 200-240V~/ 12.6A, 47-63Hz

DC Output:
- Max 1200W/ 100-127V~
+12.12V/ 95.6A
+12Vsb/ 3.5A
- Max 2200W/ 200-240V
+12.12V/ 178.1A
+12Vsb/ 3.5A

NOTE:
* The system power supply requires C19 type power cord
System Management Aspeed® AST2500 management controller
AMI MegaRAC SP-X Solution Web interface

  • Dashboard
  • JAVA Based Serial Over LAN
  • HTML5 KVM
  • Sensor Monitor (Voltage, RPM, Temperature, CPU Status …etc.)
  • Sensor Reading History Data
  • FRU Information
  • SEL Log in Linear Storage / Circular Storage Policy
  • Hardware Inventory
  • Fan Profile
  • System Firewall
  • Power Consumption
  • Power Control
  • LDAP / AD / RADIUS Support
  • Backup & Restore Configuration
  • Remote BIOS/BMC/CPLD Update
  • Event Log Filter
  • User Management
  • Media Redirection Settings
  • PAM Order Settings
  • SSL Settings
  • SMTP Settings
OS Compatibility Windows Server 2016
Windows Server 2019

Red Hat Enterprise Linux 7.8 ( x64) or later
Red Hat Enterprise Linux 7.9 ( x64) or later
Red Hat Enterprise Linux 8.2 ( x64) or later
Red Hat Enterprise Linux 8.3 ( x64) or later

SUSE Linux Enterprise Server 15 SP2 ( x64) or later

Ubuntu 20.04 LTS (x64) or later
Ubuntu 20.04.1 LTS (x64) or later

VMware ESXi 7.0 Update1 or later
VMware ESXi 7.0 Update2 or later
System Fans 8 x 80x80x38mm (16,300rpm)
Operating Properties Operating temperature: 10°C to 35°C
Operating humidity: 8-80% (non-condensing)
Non-operating temperature: -40°C to 60°C
Non-operating humidity: 20%-95% (non-condensing)
Packaging Dimensions 1180 x 779 x 300 (mm)
Packaging Content 1 x H262-PC0
8 x CPU heatsinks
1 x Rail Kit
1 x VROC module
Part Numbers Barebone package: 6NH262PC0MR-00
Spare parts:
- Motherboard: 9MH62HD0NR-00
- VROC module: 25FD0-R181N0-10R
- Rail kit: 25HB2-AN6103-K0R
- CPU heatsink: 25ST1-253208-F2R/25ST1-253209-F2R
- Back plane board: 9CBPH0O4NR-00
- Power Supply: 25EP0-222003-D0S
- C19 type power cord 125V/15A (US): 25CP1-018000-Q0R (optional)
- C19 type power cord 250V/16A (EU): 25CP3-01830H-Q0R (optional)
- C19 type power cord 250V/15A (US): 25CP1-018300-Q0R (optional)
- Ring topology kit: 6NH262Z65SR-00-100 (optional extra)