電源 (Zippy)

    DP2H-5550V(550W)

    製品仕様

    wattage 550W
    solution Server ,Workstation ,IPC ,Communication
    dimension_mm 215x100x70
    dimension_inch 8.46×3.94×2.76
    input_spec VOLTAGE: -36 ~ -72 VDC
    INPUT CURRENT: -36~-72VDC / 25~10AMP(16 AMP AT -48VDC)
    INRUSH CURRENT: 50AMPS @-48VDC (AT 25DEGREES AMBIENT COLD START)
    dc_output
















































































    Output Voltage Output Current Min. Output Current Max. Regulation Load Regulation Line Output Ripple & Noise Max.[P-P]
    +5V 0 25 ± 5% ± 50mV 50mV
    +12V 2 45 ± 5% ± 50mV 120mV
    -12V 0 0.8 ± 10% ± 100mV 120mV
    +3.3V 0 25 ± 5% ± 50mV 50mV
    +5VSB 0.1 3 ± 5% ± 50mV 50mV

    +5V AND +3.3V TOTAL OUTPUT MAX: 170W

    TOTAL OUTPUT MAX: 550W



    features * TEMPERATURE RANGE: OPERATING 0℃ — 40℃, STORAGE -20~80℃

    * HOLD UP TIME: 1.6 ms MINIMUM AT FULL LOAD & NOMINAL INPUT VOLTAGE

    * EFFICIENCY: >80% TYPICAL AT DC-48 INPUT, FULL LOAD

    * POWER GOOD SIGNAL: ON DELAY 100 ms TO 500 ms, OFF DELAY 1 ms

    * OVER POWER PROTECTION: 110~150%

    * OVER VOLTAGE PROTECTION: +5V: 5.5~6.5V, +12V: 13.2~15V, +3.3V: 3.6~4.3V

    * OVER CURRENT PROTECTION: +3.3V→27.5~37.5A, +5V→27.5~37.5A, +12V→49.5~67.5A

    * SHORT CIRCUIT PROTECTION: +5V, +3.3V, +12V, -12V, AUTO-RECOVERED: +5VSB

    * EMI NOISE FILTER: FCC CLASS A, CISPR22 CLASS A

    * SAFETY: TO MEET UL, TUV, CB

    * COOLING: 40mm DC FANS


    *THE POWER-SUPPLY IS FOR CHASSIS-ASSEMBLY ONLY AND IS NOT ALLOWED TO BE OPERATED AS STAND-ALONE COMPONENT. FINAL ASSEMBLY HAS TO COMPLY WITH CORRESPONDING EMC- AND SAFETY-REGULATIONS.
    pdf CE:http://www.zippy.com.tw//backend/DownLoad/DownLoad/Power/CE/DP2H-5550V%20(Radiation).pdf
    FCC:http://www.zippy.com.tw//backend/DownLoad/DownLoad/Power/FCC/DP2H-5550V%20FCC.pdf
    CB:http://www.zippy.com.tw//backend/DownLoad/DownLoad/Power/CB/DPxH-5V%20&%20BPxH-5V%20CB.pdf
    TUV:http://www.zippy.com.tw//backend/DownLoad/DownLoad/Power/TUV/BP1H-V%20&%20BP2H-V%20&%20DP1H-V%20&%20DP2H-V%20TUV.pdf
    CCC:http://www.zippy.com.tw//backend/DownLoad/DownLoad/Power/CCC/BP1H-V%20&%20BP2H-V%20&%20DP1H-V%20&%20DP2H-V%20CCC.pdf
    DRAWING:http://www.zippy.com.tw//backend/DownLoad/DownLoad/Power/DRAWING/DP2HVMA00.pdf