    DP2H-6400F(400W)

    製品仕様

    wattage400W
    solutionServer ,Workstation ,IPC ,Communication
    dimension_mm215x100x70
    dimension_inch8.46x3.94x2.76
    input_specVOLTAGE: DC -36V ~ -72 V INPUT CURRENT: 12A (RMS) FOR -48VDC INRUSH CURRENT: 10.0A MAX.
    dc_output
    Output Voltage Output Current Min. Output Current Max. Regulation Load Regulation Line Output Ripple & Noise Max.[P-P]
    +5V 1.0 35 ± 5% ± 50mV 50mV
    -5V 0.1 0.5 ± 10% ± 50mV 120mV
    +12V 1 22 ± 5% ± 50mV 120mV
    -12V 0 0.5 ± 5% ± 50mV 150mV
    +3.3V 1.0 20 ± 5% ± 50mV 50mV
    +5VSB 0.1 2.0 ± 5% ± 50mV 50mV


    features‧TEMPRATURE RANGE: OPERATING -10℃ ---40℃
    ‧HUMIDITY:OPERATING:20%-95%, NON-OPERATING:10%-95%
    ‧REMARKS:85% IS NORMAL CONDITION AND 95% IS WITH SPECIAL COATING PROCESS
    ‧HOLD UP TIME: 1.6ms MINUMUM AT FULL LOAD & NOMINAL INPUT VOLTAGE
    ‧DIELECTRIC WITHSTAND: INPUT/OUTPUT 1500 VAC FOR 1 SECOND
    INPUT TO FRAME GROUND 1500 VAC FOR 1 SECOND
    ‧EFFICIENCY: 65% TYPICAL, AT FULL LOAD
    ‧POWER GOOD SIGNAL: ON DELAY 100ms TO 500ms, OFF DELAY ms
    ‧OVER LOAD PROTECTION: 110~150%
    ‧OVER VOLTAGE PROTECTION: +5V→5.5V~6.5V, +3.3V→3.9V~5.0V, +12V→13.0V~15.0V
    ‧SHORT CIRCUT PROTECTION: +5V, +12V, +3.3V
    ‧EMI NOISE FILTER: FCC CLASS A, CISPR22 CLASS A
    ‧SAFETY: UL 1950, CSA 22.2 NO/950, TUV IEC 950
    ‧REMOTE ON /OFF CONTROL
    THE UNIT SHALL ACCEPT A LOGIC OPEN COLLECTOR LEVEL WHICH WILL DISABLE/ENABLE ALL THE OUTUT VOLTAGE(EXCLUDE +5V STANDBY), AS LOGIC LEVEL IS LOW, OUTPUTS VOLTAGE WERE ENABLE, AS LOGIC LEVEL IS HIGH, OUTPUTS VOLTAGE WERE DISABLE.
    ‧COOLING: 40mm DC FANS


    *THE POWER-SUPPLY IS FOR CHASSIS-ASSEMBLY ONLY AND IS NOT ALLOWED TO BE OPERATED AS STAND-ALONE COMPONENT. FINAL ASSEMBLY HAS TO COMPLY WITH CORRESPONDING EMC- AND SAFETY-REGULATIONS.
    pdfMTBF:http://www.zippy.com.tw//backend/DownLoad/DownLoad/Power/MTBF/DP2H-6400F.pdf CB:http://www.zippy.com.tw//backend/DownLoad/DownLoad/Power/CB/DP1H%20&%20DP2H%20CB.pdf TUV:http://www.zippy.com.tw//backend/DownLoad/DownLoad/Power/TUV/DP1H%20&%20DP2H%20TUV.pdf CCC:http://www.zippy.com.tw//backend/DownLoad/DownLoad/Power/CCC/DP1H%20&%20DP2H%20CCC.pdf DRAWING:http://www.zippy.com.tw//backend/DownLoad/DownLoad/Power/DRAWING/DP2HMA00.pdf DRAWING:http://www.zippy.com.tw//backend/DownLoad/DownLoad/Power/DRAWING/DP2HMA01.pdf CE:http://www.zippy.com.tw//backend/DownLoad/DownLoad/Power/CE/DP2H-6400F.pdf