電源 (Zippy)

    P2H-5400V(400W)

    製品仕様

    wattage 400W
    solution Server ,Workstation ,Storage System ,IPC
    dimension_mm 215x100x70
    dimension_inch 8.46×3.94×2.76
    input_spec VOLTAGE: 90~264 VAC FULL RANGE
    FREQUENCY: 47~63HZ
    INPUT CURRENT:6A (RMS) FOR 115 VAC/
    3A (RMS) FOR 230 VAC
    INRUSH CURRENT:40A MAX. FOR 115 VAC/
    60A MAX. FOR 230 VAC
    dc_output
















































































    Output Voltage Output Current Min. Output Current Max. Regulation Load Regulation Line Output Ripple & Noise Max.[P-P]
    +5V 1 22 ±5% ±1% 70mV
    +12V 1 32 ±5% ±1% 120mV
    -12V 0.1 0.8 ±10% ±1% 120mV
    +3.3V 1 22 ±5% ±1% 70mV
    +5VSB 0.1 3.5 ±5% ±1% 70mV




    features * TEMPERATURE RANGE:OPERATING 0℃~40℃

    * HOLD UP TIME:16mS MINIMUM AT FULL LOAD & NOMINAL INPUT VOLTAGE

    * DIELECTRIC WITHSTAND:INPUT/OUTPUT 1800 VAC FOR 1 SECOND
    INPUT TO FRAME GROUND 1800 VAC FOR 1 SECOND

    * EFFICIENCY:83% TYPICAL AT 115VAC , FULL LOAD

    * POWER GOOD SIGNAL:ON DELAY 100mS TO 500mS,OFF DELAY 1mS

    * OVER POWER PROTECTION:110~160% MAX

    * OVER VOLTAGE PROTECTION:+5V→5.6V~6.6V +3.3V→3.6V~4.3V +12V→13.2V~15V

    * SHORT CIRCUIT PROTECTION:+5V、+12V、+3.3V

    * EMI NOISE FILTER : FCC CLASS A, CISPR22 CLASS A

    * SAFETY : TO MEET UL, CUL, TUV

    * REMOTE ON/OFF CONTROL
    THE POWER SUPPLY SHALL ACCEPT A LOGIC OPEN COLLECTOR LEVEL WHICH WILL DISABLE/ENABLE ALL THE OUTPUT VOLTAGE (EXCLUDE +5V STAND BY).
    AS LOGIC LEVEL IS LOW,OUTPUTS VOLTAGE WERE ENABLE,
    AS LOGIC LEVEL IS HIGH,OUTPUTS VOLTAGE WERE DISABLE.

    * 3.3V & 5V REMOTE SENSING

    * COOLING: ONE 40mm DC FANS

    * MEET IEC-1000-3-2 CLASS D



    *THE POWER-SUPPLY IS FOR CHASSIS-ASSEMBLY ONLY AND IS NOT ALLOWED TO BE OPERATED AS STAND-ALONE COMPONENT. FINAL ASSEMBLY HAS TO COMPLY WITH CORRESPONDING EMC- AND SAFETY-REGULATIONS.
    pdf CB:http://www.zippy.com.tw//backend/DownLoad/DownLoad/Power/CB/P1H,%20P2H-V%20CB.pdf
    TUV:http://www.zippy.com.tw//backend/DownLoad/DownLoad/Power/TUV/P1H,P2H-V%20TUV.pdf
    CCC:http://www.zippy.com.tw//backend/DownLoad/DownLoad/Power/CCC/P1H,P2H-V%20CCC.pdf
    FCC:http://www.zippy.com.tw//backend/DownLoad/DownLoad/Power/FCC/P2H-5400V%20FCC.pdf
    DRAWING:http://www.zippy.com.tw//backend/DownLoad/DownLoad/Power/DRAWING/P2HVMA00.pdf
    MTBF(RoHS):http://www.zippy.com.tw//backend/DownLoad/DownLoad/Power/MTBF/P2H-5400V(RoHS).pdf
    CE:http://www.zippy.com.tw//backend/DownLoad/DownLoad/Power/CE/P2H-5400V%20(+Radiation).pdf
    MTBF(RoHS)(40℃):http://www.zippy.com.tw//backend/DownLoad/DownLoad/Power/MTBF/P2H-5400V(RoHS)(40%e2%84%83).pdf