製品仕様
| Product SKUs | |
|---|---|
| AS-1022G-NTF | A+ Server 1022G-NTF (Black) |
| Processor/Chipset | |
| CPU | Dual 1944-pin Socket G34 Supports up to two 16/12/8/4-Core ready AMD Opteron 6000 Series processors HT3.0 Link support |
| 3.2GHz Hyper-Transport (HT3) link | |
| Chipset | AMD chipset SR5670 / SP5100 |
| Note | Supports 6000 processors with Max ACP 80W (TDP 115W) |
| System Memory | |
| Memory Capacity | 16 DIMM sockets Support up to 512GB Registered ECC or 128GB Unbuffered ECC/non-ECC 1600/1333/1066 SDRAM in 16 DIMMs Quad channel memory bus For Dual or Quad CPUs: Recommended that memory be populated equally in adjacent memory banks SC815TQ-563UB |
| Dimensions | |
| Height | 1.7" (43mm) |
| Width | 17.2" (437mm) |
| Depth | 25.6" (650mm) |
| Gross Weight | 36 lbs (16.4kg) |
| Available Colors | Black |
| Front Panel | |
| Buttons | Power On/Off button System Reset button |
| LEDs | Power LED Hard drive activity LED 2x Network activity LEDs System Overheat LED (UID LED) |
| Drive Bays | |
| Hot-swap | 4x 3.5" SATA Hot-swap drive trays Enterprise SATA HDD only recommended |
| Peripheral Drives | |
| DVD-ROM | Slim DVD-ROM drive |
| System Cooling | |
| Fans | 4x 4cm Counter-rotating PWM fans |
| Power Supply | |
| AC Voltage | 100-240 V, 50-60 Hz, 7.5 Amp max |
| +5V | 18 Amp |
| +5V standby | 3 Amp |
| +12V | 46 Amp @ 100-180V; 49 Amp @ 180-240V |
| -12V | 0.5 Amp |
| +3.3V | 15 Amp |
| Certification | |
| PC Health Monitoring | |
| CPU | Monitors CPU Core Voltages, +3.3V, +5V, ±12V, HyperTransport Link voltage, memory voltage, VBAT, Chipset voltage CPU switching voltage regulator |
| FAN | Total up to 8-fan status tachometer monitoring Status monitor for speed control Stauts monitor for on/off control Low noise fan speed control |
| Temperature | Monitoring for CPU and chassis environment CPU Thermal Trip Support Thermal Control for 8x Fan Connectors I2C Temperature Sensing Logic |
| LED | CPU / System Overheat LED Suspend-State Indicator LED +5V Standby Alert LED UID/Remote LED |
| Other Features | Chassis Intrusion Detection Chassis Intrusion Header |
| Operating Environment / Compliance | |
| RoHS | RoHS Compliant |
| Environmental Spec. | Operating Temperature: 10°C to 30°C (50°F to 86°F) Non-operating Temperature: -40°C to 70°C (-40°F to 158°F) Operating Relative Humidity: 8% to 90% (non-condensing) Non-operating Relative Humidity: 5% to 95% (non-condensing) |
ご注文から納品までの流れ「発注方法がわからない」「納品までの流れがイメージできない」そんな不安を解消いたします!
-
お問い合わせ
まずは、お電話またはお問い合わせフォームよりご連絡ください。
ご希望のサーバーやシステム構成、導入目的、台数、納期などについて、ヒアリングさせていただきます。以下の情報をお知らせいただければ、スムーズに製品提案が可能でございます。
・CPU (コア数,クロック数)
・メモリ (容量)
・ストレージ (SSD/HDD,SATA/SAS/NVMe, 容量, 本数)
・OS
・GPU等拡張カードの有無
・I/Oポート仕様
・保証期間 (センドバック対応が標準です。オンサイト保守をご希望の際はご指示ください。)
・希望納期お問い合わせ先
Tel:03-3815-9001
URL:https://www.sunwaytech.co.jp/contact/ -
ご提案・お見積り
お客様のニーズに合った最適なサーバーや構成をご提案し、お見積書を作成いたします。
技術的なご質問やカスタマイズのご要望にも柔軟に対応いたしますので、お気軽にご相談ください。 -
ご注文
お見積り内容にご納得いただけましたら、ご注文書をご提出ください。
ご注文後、正式な納期や手配状況をご案内いたします。 -
入荷検査・キッティング
海外メーカーよりサーバーが入荷後、弊社にて検品および動作確認を行います。
ご要望に応じて、初期設定やOSのインストールなども承ります。 -
納品
ご指定の場所へサーバーを発送いたします。
納品時に万が一トラブルが発生した場合も、迅速にサポートいたします。 -
アフターサポート
納品後も安心してご利用いただけるよう、サポート体制を整えております。
ご購入者様向けの会員サイトからRMA申請・修理状況の確認が可能です。サポート窓口
Tel:03-3815-9001
URL:https://member.sunwaytech.co.jp/login安心・確実なサーバー導入をサポートいたします!
まずはお気軽にお問い合わせください。