    DR1S2-5380V4H(380W)

    製品仕様

    wattage380W
    solutionServer ,Workstation ,Storage System ,IPC ,Communication ,Networking
    dimension_mm230x176x41.8
    dimension_inch9.06x6.93x1.65
    input_specVOLTAGE:-36 ~ -72VDC FREQUENCY: DC STEADY-STATE CURRENT: 15/7A MAXIMUN AT ANY LOW/HIGH RANGE INPUT VOLTAGE INRUSH CURRENT: 70A MAX. @-48VDC INPUT (AT 25DEGREES AMBIENT COLD START) START UP CURRENT: 13AMPS MAX. @ -48VDC INPUT
    dc_output
    Output Voltage Output Current Min. Output Current Max. Regulation Load Regulation Line Output Ripple & Noise Max.[P-P]
    +5V 0.5 20 ±5% ±1% 50mV
    +12V 2 30 ±5% ±1% 120mV
    -12V 0.1 0.5 ±10% ±1% 120mV
    +3.3V 0.5 20 ±5% ±1% 50mV
    +5VSB 0.1 2.5 ±5% ±1% 50mV
    * POWER MODULE TOTAL OUTPUT POWER OF +5V AND +3.3V NOT EXCEED 140W
    * TOTAL OUTPUT MAX 380W
    * WHEN CONDITIONS OF BOTH +5V/0A & +3.3V/0A, MIN LOAD OF 4A AT +12V IS A MUST


    features* TEMPERATURE RANGE:OPERATING 0℃~50℃, STOREAGE -20℃~80℃
    * HOLD UP TIME:1.6mS MIN.
    * DIELECTRIC WITHSTAND:INPUT/OUTPUT 1500 VAC FOR 1 MINUTE INPUT TO FRAME GROUND 1500 VAC FOR 1 MINUTE
    * EFFICIENCY: POWER SUPPLY EFFICIENCY TYPICAL >80% AT -48VDC
    * OVER POWER PROTECTION: 110~160%
    * OVER VOLTAGE PROTECTION:+3.3V→3.6V~5V,+5V→5.6V~6.7V,+12V→13V~17V
    * SHORT CIRCUIT PROTECTION: +5V, +3.3V, +12V, -12V
    * REMOTE ON / OFF CONTROL
    * REMOTE SENSING DESIGN
    * BALANCE LOAD SHARING DESIGN
    * HOT-SWAPPABLE/HOT PLUGGABLE REDUNDANCY FUNCTION
    * ISOLATION: BUILT-IN THE POWER MODULE
    * FAULTY ALARM METHODS: LED, BUZZER, TTL SIGNAL
    * EMI NOISE FILTER: FCC CLASS A , CISPR 22 CLASS A
    * SAFETY:MEET UL, CUL, TUV, CCC


    *THE POWER-SUPPLY IS FOR CHASSIS-ASSEMBLY ONLY AND IS NOT ALLOWED TO BE OPERATED AS STAND-ALONE COMPONENT. FINAL ASSEMBLY HAS TO COMPLY WITH CORRESPONDING EMC- AND SAFETY-REGULATIONS.
    pdfDRAWING:http://www.zippy.com.tw//backend/DownLoad/DownLoad/Power/DRAWING/DR1S2MA00.pdf CE:http://www.zippy.com.tw//backend/DownLoad/DownLoad/Power/CE/DR1S2-5380V4H.pdf FCC:http://www.zippy.com.tw//backend/DownLoad/DownLoad/Power/FCC/DR1S2-5380V4H%20FCC.pdf CB:http://www.zippy.com.tw//backend/DownLoad/DownLoad/Power/CB/DP1S,%20DR1S2-V4V,%20DR1S2-V4H%20CB.pdf TUV:http://www.zippy.com.tw//backend/DownLoad/DownLoad/Power/TUV/DP1S,%20DR1S2-V4V,%20DR1S2-V4H%20TUV.pdf CCC:http://www.zippy.com.tw//backend/DownLoad/DownLoad/Power/CCC/DR1S2-V%20CCC.pdf MTBF(RoHS):http://www.zippy.com.tw//backend/DownLoad/DownLoad/Power/MTBF/DR1S2-5380V4H(RoHS).pdf CE(Radiation):http://www.zippy.com.tw//backend/DownLoad/DownLoad/Power/CE/DR1S2-5380V4H%20(Radiation).pdf