電源 (Zippy)

    R1S2-5300V4H(300W)

    製品仕様

    wattage300W
    solutionServer ,Workstation ,Storage System
    dimension_mm230x176x41.8
    dimension_inch9.06x6.93x1.65
    input_specVOLTAGE: 90~264VAC FULL RANGE FREQUENCY: 47~63HZ INPUT CURRENT:4.5A (RMS) FOR 115 VAC 2.0A (RMS) FOR 230 VAC INRUSH CURRENT:15A MAX. FOR 115 VAC PER MODULE 30A MAX. FOR 230 VAC PER MODULE
    dc_output
    Output Voltage Output Current Min. Output Current Max. Regulation Load Regulation Line Output Ripple & Noise Max.[P-P]
    +5V 0.5 20 ±5% ±1% 50mV
    +12V 2.0 24 ±5% ±1% 120mV
    -12V 0.1 0.5 ±10% ±1% 120mV
    +3.3V 0.5 20 ±5% ±1% 50mV
    +5VSB 0.1 2.5 ±5% ±1% 50mV
    * +5V AND +3.3V TOTAL OUTPUT MAX: 140W
    * TOTAL OUTPUT MAX: 300W
    * THE CONDITIONS OF BOTH +5V/0A & +3.3V/0A, MIN LOAD OF 4A AT +12V IS MUST.


    features* TEMPERATURE RANGE:OPERATING 0℃~40℃, STORAGE -20℃~80℃
    * HOLD UP TIME:WHEN POWER SHUTDOWN DC OUTPUT 5V MUST BE MAINTAIN 16MSEC IN REGULATION LIMIT AT NORMAL INPUT VOLTAGE
    * EFFICIENCY:84% TYPICAL,AT FULL LOAD 115VAC
    * LEAKAGE CURRENT: 3.5 MA. MAX. AT NOMINAL VOLTAGE 250VAC
    * POWER GOOD SIGNAL:ON DELAY 100mS TO 550mS,OFF DELAY 1Ms
    * OVER POWER PROTECTION:110~160% MAX
    * OVER VOLTAGE PROTECTION: +5V→5.6~6.7V, +3.3V→3.6~4.3V, +12V→13~16V
    * SHORT CIRCUIT PROTECTION: +5V, +3.3V, +12V, -12V, +5VSB
    * SAFETY: MEET UL60950, TUV EN-60950, CB IEC 60950
    * WARNING METHOD: AUDIO ALARM(BUZZER SOUND, RESETABLE), FALUT LED, TTL


    *THE POWER-SUPPLY IS FOR CHASSIS-ASSEMBLY ONLY AND IS NOT ALLOWED TO BE OPERATED AS STAND-ALONE COMPONENT. FINAL ASSEMBLY HAS TO COMPLY WITH CORRESPONDING EMC- AND SAFETY-REGULATIONS.
    pdfTUV:http://www.zippy.com.tw//backend/DownLoad/DownLoad/Power/TUV/P1S-2400V%20&%20R1S2-V%20TUV.pdf DRAWING:http://www.zippy.com.tw//backend/DownLoad/DownLoad/Power/DRAWING/R1S2MA00.pdf CCC:http://www.zippy.com.tw//backend/DownLoad/DownLoad/Power/CCC/P1S-2400V%20&%20R1S2-V%20CCC.pdf MTBF(ROHS):http://www.zippy.com.tw//backend/DownLoad/DownLoad/Power/MTBF/R1S2-5300V4H(RoHS).pdf CB:http://www.zippy.com.tw//backend/DownLoad/DownLoad/Power/CB/P1S-2400V%20&%20R1S2-V%20CB.pdf MTBF(RoHS)(50℃)(NO FAN):http://www.zippy.com.tw//backend/DownLoad/DownLoad/Power/MTBF/R1S2-5300V4H(RoHS)(50%e2%84%83)(NO%20FAN).pdf MTBF(RoHS)(50℃):http://www.zippy.com.tw//backend/DownLoad/DownLoad/Power/MTBF/R1S2-5300V4H(RoHS)(50%e2%84%83).pdf MTBF(RoHS)(No FAN):http://www.zippy.com.tw//backend/DownLoad/DownLoad/Power/MTBF/R1S2-5300V4H(RoHS)(NO%20FAN).pdf CE(Radiation):http://www.zippy.com.tw//backend/DownLoad/DownLoad/Power/CE/R1S2-5300V4H%20(+Radiation).pdf CE(Radiation):http://www.zippy.com.tw//backend/DownLoad/DownLoad/Power/CE/R1S2-5300V4H%20(Radiation).pdf FCC:http://www.zippy.com.tw//backend/DownLoad/DownLoad/Power/FCC/R1S2-5300V4H%20FCC.pdf