製品仕様
wattage | 250W | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
solution | Server ,Workstation ,Storage System ,IPC | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
dimension_mm | 190x100x40 | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
dimension_inch | 7.48x3.94x1.57 | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
input_spec | VOLTAGE: 90 ~ 264 VAC FULL RANGE FREQUENCY : 47 ~ 63 HZ INPUT CURRENT: 4~2 AMPS MAXIMUM AT ANY LOW/HIGH RANGE INPUT VOLTAGE. INRUSH CURRENT: 65/130 AMPS @110/220 VAC (AT 25 DEGREES AMBIENT COLD START) | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
dc_output |
2. +5V,+3.3V AND +12V TOTAL OUTPUT MAX : 236W 3. +3.3V CURRENT DERATING LINEARLY TO 10A AT 45℃ | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
features | * TEMPERATURE RANGE: OPERATING 0℃ ~ 45℃, STORAGE -20℃~80℃ * EFFICIENCY: POWER SUPPLY EFFICIENCY TYPICAL 65% AT 115V,FULL LOAD. * HOLD UP TIME: WHEN POWER SHUTDOWN DC OUTPUT 5V MUST BE MAINTAIN 16MSEC IN REGULATION LIMIT AT NORMAL INPUT VOLTAGE * HUMIDITY:OPERATING:20%-80%, NON-OPERATING:10%-90% * REMARKS:85% IS NORMAL CONDITION AND 95% IS WITH SPECIAL COATING PROCESS * OVER POWER PROTECTION: 110~160% * OVER VOLTAGE PROTECTION: +5V :5.6V ∼ 6.6V, +3.3V :3.6V ∼ 4.2V, +12V :13.2V ∼ 14.6V * SHORT CIRCUIT PROTECTION * LEAKAGE CURRENT: 3.5 MA. MAX. AT NOMINAL VOLTAGE 250 VAC * SAFETY: TO MEEET UL, CUL, TUV * REMOTE ON/OFF CONTROL *THE POWER-SUPPLY IS FOR CHASSIS-ASSEMBLY ONLY AND IS NOT ALLOWED TO BE OPERATED AS STAND-ALONE COMPONENT. FINAL ASSEMBLY HAS TO COMPLY WITH CORRESPONDING EMC- AND SAFETY-REGULATIONS. | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
FCC:http://www.zippy.com.tw//backend/DownLoad/DownLoad/Power/FCC/P1U-6250P%20FCC.pdf CCC:http://www.zippy.com.tw//backend/DownLoad/DownLoad/Power/CCC/P1U%20SERIES%20CCC.pdf MTBF(RoHS):http://www.zippy.com.tw//backend/DownLoad/DownLoad/Power/MTBF/P1U-6250P(RoHS).pdf CE:http://www.zippy.com.tw//backend/DownLoad/DownLoad/Power/CE/P1U-6250P.pdf |
ご注文から納品までの流れ「発注方法がわからない」「納品までの流れがイメージできない」そんな不安を解消いたします!
キーワードから探す
CLOSE