電源 (Zippy)

    M1S2-5400V4H(400W)

    製品仕様

    wattage400W
    solutionServer ,Workstation ,Storage System
    dimension_mm355x106x41.3
    dimension_inch13.98x4.17x1.63
    input_specVOLTAGE: 90~264VAC FULL RANGE FREQUENCY: 47~63HZ INPUT CURRENT:3A(RMS)FOR HIGH RANGE INPUT VOLTAGE 6A(RMS)FOR LOW RANGE INPUT VOLTAGE INRUSH CURRENT:20A MAX. FOR 132 VAC PER MODULE 40A MAX. FOR 264 VAC PER MODULE
    dc_output
    Output Voltage Output Current Min. Output Current Max. Regulation Load Regulation Line Output Ripple & Noise Max.[P-P]
    +5V 1 25 ±5% ±1% 50mV
    +12V 2 33 ±5% ±1% 120mV
    -12V 0 0.8 ±10% ±1% 120mV
    +3.3V 1 25 ±5% ±1% 50mV
    +5VSB 0.1 3.5 ±5% ±1% 50mV


    features* TEMPERATURE RANGE:OPERATING 0℃~40℃,STORAGE -20℃~80℃
    * HOLD UP TIME:16mS MIN. AT FULL LOAD & 115 VAC INPUT VOLTAGE
    * DIELECTRIC WITHSTAND:INPUT/OUTPUT 1500 VAC FOR 1 minute, INPUT TO FRAME GROUND 1500 VAC FOR 1 MINUTE
    * EFFICIENCY:84% / 85% MAX. TYPICAL AT FULL LOAD
    * POWER GOOD SIGNAL:ON DELAY 100mS TO 500mS,OFF DELAY 1Ms
    * OVER POWER PROTECTION:110~150% MAX
    * OVER VOLTAGE PROTECTION:+5V→5.8V~6.9V,+3.3V→3.9V~4.6V ,+12V→13.9V~16.4V
    * OVER CURRENT PROTECTION: +3.3V→27.5~37.5A, +5V→27.5~37.5A, +12V→36.3~49.5A
    * SHORT CIRCUIT: +12V, -12V, +3.3V, +5V, +5VSB
    * EMI : FCC CLASS A , CISPR 22 CLASS A
    * SAFETY:UL 60950-1, CSA 22.2 NO.60950-1-03 1ST Edition , TUV IEC60950-1, CCC
    * FAULTY ALARM METHODS: LED, BUZZER, TTL SIGNAL
    * MEET IEC-1000-3-2 CLASS D (ACTIVE PFC)
    * HOT-SWAPPABLE/HOT PLUGGABLE REDUNDANCY FUNCTION
    * DIMENSION: 355(D) * 106(W) * 41.3 (H)mm
    * COOLING: ONE 40mm DC FANS (MODULE)
    * AC INLET IN EACH MODULE


    *THE POWER-SUPPLY IS FOR CHASSIS-ASSEMBLY ONLY AND IS NOT ALLOWED TO BE OPERATED AS STAND-ALONE COMPONENT. FINAL ASSEMBLY HAS TO COMPLY WITH CORRESPONDING EMC- AND SAFETY-REGULATIONS.
    pdfDRAWING:http://www.zippy.com.tw//backend/DownLoad/DownLoad/Power/DRAWING/M1S2MA00.pdf CB:http://www.zippy.com.tw//backend/DownLoad/DownLoad/Power/CB/M1S-V%20&%20M1S2-V%20%20CB.pdf TUV:http://www.zippy.com.tw//backend/DownLoad/DownLoad/Power/TUV/M1S-V%20&%20M1S2-V%20TUV.pdf MANUAL:http://www.zippy.com.tw//backend/DownLoad/DownLoad/Power/MANUAL/M1S2.pdf CCC:http://www.zippy.com.tw//backend/DownLoad/DownLoad/Power/CCC/M1S-V%20&%20M1S2-V%20CCC.pdf MTBF(ROHS):http://www.zippy.com.tw//backend/DownLoad/DownLoad/Power/MTBF/M1S2-5400V4H(RoHS).pdf MTBF(RoHS)(45℃):http://www.zippy.com.tw//backend/DownLoad/DownLoad/Power/MTBF/M1S2-5400V4H(RoHS)(45%e2%84%83).pdf MTBF(RoHS)(60℃):http://www.zippy.com.tw//backend/DownLoad/DownLoad/Power/MTBF/M1S2-5400V4H(RoHS)(60%e2%84%83).pdf MTBF(RoHS)(35℃):http://www.zippy.com.tw//backend/DownLoad/DownLoad/Power/MTBF/M1S2-5400V4H(RoHS)(35%e2%84%83).pdf DRAWING:http://www.zippy.com.tw//backend/DownLoad/DownLoad/Power/DRAWING/M1S0MA00.pdf CE:http://www.zippy.com.tw//backend/DownLoad/DownLoad/Power/CE/M1S2-5400V4H%20(+Radiation).pdf BSMI:http://www.zippy.com.tw//backend/DownLoad/DownLoad/Power/BSMI/M1S-V%20,%20M1S2-V%20BSMI.pdf MTBF(SR-332 Issue2):http://www.zippy.com.tw//backend/DownLoad/DownLoad/Power/MTBF/M1S2-5400V4H%20MTBF%20T25%20(SR-332%20Issue2).pdf MTBF(SR-332 Issue3):http://www.zippy.com.tw//backend/DownLoad/DownLoad/Power/MTBF/M1S2-5400V4H%20MTBF%20T25%20(SR-332%20Issue3).pdf

    ご注文から納品までの流れ「発注方法がわからない」「納品までの流れがイメージできない」そんな不安を解消いたします!

    複数条件から探す

    メーカー、筐体サイズ、仕様(CPU、CPUソケット数、最大GPU数)、特長・用途などから製品を探せます。

    キーワードから探す

    CLOSE

    サーバー・産業用PCに関するご相談・お見積りなど
    お気軽にお問い合わせをください。

    03-3815-9001 受付時間/平日9:30 〜 18:00