電源 (Zippy)

    P2H-6400P(400W)

    製品仕様

    wattage400W
    solutionServer ,Workstation ,Storage System ,IPC
    dimension_mm215x100x70
    dimension_inch8.46x3.94x2.76
    input_specVOLTAGE: 90 ~ 264 VAC FULL RANGE FREQUENCY : 47 ~ 63 HZ INPUT CURRENT: 8.0 A ( RMS ) FOR 110VAC 4.0 A ( RMS ) FOR 220VAC INRUSH CURRENT: 60A MAX. FOR 110 VAC 80A MAX. FOR 220 VAC
    dc_output
    Output Voltage Output Current Min. Output Current Max. Regulation Load Regulation Line Output Ripple & Noise Max.[P-P]
    5V 3 25 ± 5% ± 1% 80mV
    12V 2 28 ± 6% ± 1% 120mV
    -5V 0 0.5 ±10% ± 1% 150mV
    -12V 0 0.5 ±10% ± 1% 150mV
    3.3V 1 20 ± 5% ± 1% 80mV
    +5VSB 0.1 2 ± 5% ± 1% 80mV
    REMARKS:
    THE OUTPUT POWER OF 5V & 3.3V NOT EXCEED 175W; 5V & 3.3V &12V NOT EXCEED 384WATTS


    features*Active PFC (full range), MEET IEC-1000-3-2 CLASS D
    *12V Max. Current :28A
    *TEMPERATURE RANGE: OPERATING 0℃ ~ 40℃.
    * HUMIDITY:OPERATING:20%-95%, NON-OPERATING:10%-95%
    * REMARKS:85% IS NORMAL CONDITION AND 95% IS WITH SPECIAL COATING PROCESS
    *OVER POWER PROTECTION
    *OVER VOLTAGE PROTECTION
    *SHORT CIRCUIT PROTECTION
    *EMI NOISE FILTER: FCC CLASS B, CISPR22 CLASS B
    *SAFETY: UL, CSA, TUV
    *Remote on/off control
    *Cooling: ONE 60 mm DC Fan
    *Serial ATA optional

    *THE POWER-SUPPLY IS FOR CHASSIS-ASSEMBLY ONLY AND IS NOT ALLOWED TO BE OPERATED AS STAND-ALONE COMPONENT. FINAL ASSEMBLY HAS TO COMPLY WITH CORRESPONDING EMC- AND SAFETY-REGULATIONS.
    pdfDRAWING:http://www.zippy.com.tw//backend/DownLoad/DownLoad/Power/DRAWING/P2H0MA00.pdf CB:http://www.zippy.com.tw//backend/DownLoad/DownLoad/Power/CB/P1H,P2H%20CB.pdf CCC:http://www.zippy.com.tw//backend/DownLoad/DownLoad/Power/CCC/P1H,P2H%20CCC.pdf TUV:http://www.zippy.com.tw//backend/DownLoad/DownLoad/Power/TUV/P1H,P2H%20TUV.pdf MTBF:http://www.zippy.com.tw//backend/DownLoad/DownLoad/Power/MTBF/P2H-6400P.pdf FCC:http://www.zippy.com.tw//backend/DownLoad/DownLoad/Power/FCC/P2H-6400P-FCC.pdf MTBF(RoHS):http://www.zippy.com.tw//backend/DownLoad/DownLoad/Power/MTBF/P2H-6400P(RoHS).pdf MTBF(RoHS)(40℃):http://www.zippy.com.tw//backend/DownLoad/DownLoad/Power/MTBF/P2H-6400P(RoHS)(40%e2%84%83).pdf MTBF(RoHS)(50℃):http://www.zippy.com.tw//backend/DownLoad/DownLoad/Power/MTBF/P2H-6400P(RoHS)(50%e2%84%83).pdf MTBF(RoHS)(60℃:http://www.zippy.com.tw//backend/DownLoad/DownLoad/Power/MTBF/P2H-6400P(RoHS)(60%e2%84%83).pdf FCC:http://www.zippy.com.tw//backend/DownLoad/DownLoad/Power/FCC/P2H-6400P%20FCC.pdf CE:http://www.zippy.com.tw//backend/DownLoad/DownLoad/Power/CE/P2H-6400P%20(+Radiation).pdf