電源 (Zippy)

    P2U-6300P(300W)

    製品仕様

    wattage300W
    solutionServer ,Workstation ,Storage System ,IPC
    dimension_mm200x100x70
    dimension_inch7.87x3.94x2.76
    input_specVOLTAGE: 90 ~ 264 VAC FULL RANGE FREQUENCY : 47 ~ 63 HZ INPUT CURRENT: 6.0 A ( RMS ) FOR 115VAC 3.0 A ( RMS ) FOR 230VAC INRUSH CURRENT: 60.0A MAX. FOR 115 VAC 80.0A MAX. FOR 230 VAC
    dc_output
    Output Voltage Output Current Min. Output Current Max. Regulation Load Regulation Line Output Ripple & Noise Max.[P-P]
    5V 3 35 ± 5% ± 1% 80mV
    12V 2 16 ± 8% ± 1% 120mV
    -5V 0.05 0.5 ±10% ± 1% 120mV
    -12V 0.05 1 ±10% ± 1% 150mV
    3.3V 1 20 ± 5% ± 1% 70mV
    +5VSB 0.1 2 ± 5% ± 1% 60mV


    features*Active PFC (full range), MEET IEC-1000-3-2 CLASS D
    *12V Max. Current :16A
    *TEMPERATURE RANGE: OPERATING 0℃ ~ 40℃.
    * HUMIDITY:OPERATING:20%-95%, NON-OPERATING:10%-95%
    * REMARKS:85% IS NORMAL CONDITION AND 95% IS WITH SPECIAL COATING PROCESS
    *EMI NOISE FILTER: FCC CLASS B, CISPR22 CLASS B
    *OVER POWER PROTECTION
    *OVER VOLTAGE PROTECTION
    *SHORT CIRCUIT PROTECTOIN
    *SAFETY: UL, CSA, TUV
    *Remote on/off control
    *Cooling: TWO 60 mm DC Fans
    *3.3V /5V Remote sensing
    *Serial ATA optional

    *THE POWER-SUPPLY IS FOR CHASSIS-ASSEMBLY ONLY AND IS NOT ALLOWED TO BE OPERATED AS STAND-ALONE COMPONENT. FINAL ASSEMBLY HAS TO COMPLY WITH CORRESPONDING EMC- AND SAFETY-REGULATIONS.
    pdfDRAWING:http://www.zippy.com.tw//backend/DownLoad/DownLoad/Power/DRAWING/P2U0MA00.pdf CB:http://www.zippy.com.tw//backend/DownLoad/DownLoad/Power/CB/P2U-P%20CB.pdf FCC:http://www.zippy.com.tw//backend/DownLoad/DownLoad/Power/FCC/P2U-6300P.pdf TUV:http://www.zippy.com.tw//backend/DownLoad/DownLoad/Power/TUV/P2U-P%20TUV.pdf MTBF:http://www.zippy.com.tw//backend/DownLoad/DownLoad/Power/MTBF/P2U-6300P.pdf CCC:http://www.zippy.com.tw//backend/DownLoad/DownLoad/Power/CCC/P2U-P%20CCC.pdf MTBF(RoHS):http://www.zippy.com.tw//backend/DownLoad/DownLoad/Power/MTBF/P2U-6300P(RoHS).pdf MTBF(RoHS)(50℃)(NO FAN):http://www.zippy.com.tw//backend/DownLoad/DownLoad/Power/MTBF/P2U-6300P(RoHS)(50%e2%84%83)(NO%20FAN).pdf MTBF(RoHS)(50℃):http://www.zippy.com.tw//backend/DownLoad/DownLoad/Power/MTBF/P2U-6300P(RoHS)(50%e2%84%83).pdf MTBF(RoHS)(NO FAN):http://www.zippy.com.tw//backend/DownLoad/DownLoad/Power/MTBF/P2U-6300P(RoHS)(NO%20FAN).pdf FCC:http://www.zippy.com.tw//backend/DownLoad/DownLoad/Power/FCC/P2U-6300P%20FCC.pdf CE:http://www.zippy.com.tw//backend/DownLoad/DownLoad/Power/CE/P2U-6300P%20(+Radiation).pdf CE(Radiation):http://www.zippy.com.tw//backend/DownLoad/DownLoad/Power/CE/P2U-6300P%20(Radiation).pdf