電源 (Zippy)

    M1K2-5C01V4H(1200W)

    製品仕様

    wattage1200W
    solutionServer ,Workstation ,Storage System
    dimension_mm400x106x41.3
    dimension_inch15.75x4.17x1.63
    input_specVOLTAGE: 90~264VAC FULL RANGE FREQUENCY: 47~63HZ INPUT CURRENT:7.5A (RMS)FOR 230VAC 15A(RMS)FOR 115VAC INRUSH CURRENT:15A MAX. FOR 115 VAC PER MODULE 30A MAX. FOR 230 VAC PER MODULE
    dc_output
    Output Voltage Output Current Min. Output Current Max. Regulation Load Regulation Line Output Ripple & Noise Max.[P-P]
    +5V 0 36 ±5% ±1% 50mV
    +12V 2 100 ±5% ±1% 120mV
    -12V 0 0.5 ±5% ±1% 120mV
    +3.3V 0 31 ±5% ±1% 50mV
    +5VSB 0.1 3 ±5% ±1% 50mV
    * POWER MODULE TOTAL OUTPUT POWER OF +5V AND +3.3V NOT EXCEED 210W
    * POWER MODULE TOTAL OUTPUT POWER NOT EXCEED 1200W


    features* TEMPERATURE RANGE:OPERATING 0℃~50℃,STORAGE -20℃~80℃
    * HOLD UP TIME:10mS MIN. AT FULL LOAD & 115 VAC INPUT VOLTAGE
    * DIELECTRIC WITHSTAND:INPUT/OUTPUT 1500 VAC FOR 1 minute INPUT TO FRAME GROUND 1500 VAC FOR 1 minute
    * EFFICIENCY:TYPICAL 83% AT 115V, 12V/83A 5VSB/0.1A; TYPICAL 86% AT 230V, 12V/83A 5VSB/0.1A
    * POWER GOOD SIGNAL:ON DELAY 100mS TO 500mS,OFF DELAY 1mS
    * OVER POWER PROTECTION:110~150% MAX
    * OVER VOLTAGE PROTECTION:+3.3V→3.7~4.1V, +5V→5.7~6.5V, +12V→12.8~13.9V
    * SHORT CIRCUIT PROTECTION: +5V, +3.3V, +12V, -12V
    * SAFETY:TO MEET UL, CUL, TUV
    * FAULTY ALARM METHODS: LED, BUZZER, TTL SIGNAL
    * MEET IEC-1000-3-2 CLASS D (ACTIVE PFC)


    * THE POWER-SUPPLY IS FOR CHASSIS-ASSEMBLY ONLY AND IS NOT ALLOWED TO BE OPERATED AS STAND-ALONE COMPONENT. FINAL ASSEMBLY HAS TO COMPLY WITH CORRESPONDING EMC- AND SAFETY-REGULATIONS.
    pdfDRAWING:http://www.zippy.com.tw//backend/DownLoad/DownLoad/Power/DRAWING/M1K2MA01.pdf CB:http://www.zippy.com.tw//backend/DownLoad/DownLoad/Power/CB/M1K-V%20and%20M1K2-V%20CB.pdf TUV:http://www.zippy.com.tw//backend/DownLoad/DownLoad/Power/TUV/M1K-V%20and%20M1K2-V%20TUV.pdf CCC:http://www.zippy.com.tw//backend/DownLoad/DownLoad/Power/CCC/M1K-V%20and%20M1K2-V%20CCC.pdf MTBF(RoHS)(35℃):http://www.zippy.com.tw//backend/DownLoad/DownLoad/Power/MTBF/M1K2-5C01V4H(RoHS)(35%e2%84%83).pdf MTBF(RoHS):http://www.zippy.com.tw//backend/DownLoad/DownLoad/Power/MTBF/M1K2-5C01V4H(RoHS).pdf CE (Radiation):http://www.zippy.com.tw//backend/DownLoad/DownLoad/Power/CE/M1K2-5C01V4H%20(Radiation).pdf FCC:http://www.zippy.com.tw//backend/DownLoad/DownLoad/Power/FCC/M1K2-5C01V4H%20FCC.pdf MTBF(RoHS)(40℃):http://www.zippy.com.tw//backend/DownLoad/DownLoad/Power/MTBF/M1K2-5C01V4H(RoHS)(40%e2%84%83).pdf