電源 (Zippy)

    MHU2-5400V(400W)

    製品仕様

    wattage400W
    solutionServer ,Workstation ,Storage System ,IPC ,Networking
    dimension_mm150x140x86
    dimension_inch5.91x5.51x3.39
    input_specVOLTAGE:100~240VAC FULL RANGE(WITH ±10% TOLERANCE) FREQUENCY:47~63HZ INPUT CURRENT:6A (RMS) FOR 115 VAC 3A (RMS) FOR 230 VAC INRUSH CURRENT:20A MAX. FOR 115 VAC 40A MAX. FOR 230 VAC
    dc_output
    Output Voltage Output Current Min. Output Current Max. Regulation Load Regulation Line Output Ripple & Noise Max.[P-P]
    +5V 0.5 18 ±5% ±1% 50mV
    +12V 2 32 ±5% ±1% 120mV
    -12V 0 0.5 ±5% ±1% 120mV
    +3.3V 0.5 18 ±5% ±1% 50mV
    +5VSB 0.1 2 ±5% ±1% 50mV
    +5V AND +3.3V TOTAL MAX.:30A TOTAL POWER: 400W(MAX)

    features* TEMPERATURE RANGE:OPERATING 0℃~40℃
    * HOLD UP TIME:16mS MINIMUM AT 115V LOAD
    * EFFICIENCY:80-85% TYPICAL,AT 25℃ FULL LOAD 115VAC
    * POWER GOOD SIGNAL:ON DELAY 100mS TO 500mS,OFF DELAY 1Ms
    * OVER POWER PROTECTION: 120~160% MAX
    * OVER VOLTAGE PROTECTION: +5V→5.6V~6.5V, +3.3V→3.6V~4.3V, +12V→13.2V~15V
    * SHORT CIRCUIT PROTECTION: +5V、+12V、-12V、+3.3V
    * RESTART AFTER PRETECTION
    * EMI NOISE FILTER: FCC CLASS B, CISPR22 CLASS B
    * SAFETY: TO MEET UL60601, TUV EN-60601
    * LEAKAGE CURRENT: 0.3mA. MAX. AT NOMINAL VOLTAGE 264VAC
    * REMOTE ON/OFF CONTROL: THE POWER SUPPLY SHALL ACCEPT A LOGIC OPEN COLLECTOR LEVEL WHICH WILL DISABLE/ENABLE ALL THE OUTPUT VOLTAGE (EXCLUDE +5V STAND BY). AS LOGIC LEVEL IS LOW,OUTPUTS VOLTAGE WERE ENABLE,AS LOGIC LEVEL IS HIGH,OUTPUTS VOLTAGE WERE DISABLE.


    *THE POWER-SUPPLY IS FOR CHASSIS-ASSEMBLY ONLY AND IS NOT ALLOWED TO BE OPERATED AS STAND-ALONE COMPONENT. FINAL ASSEMBLY HAS TO COMPLY WITH CORRESPONDING EMC- AND SAFETY-REGULATIONS.
    pdfDRAWING:http://www.zippy.com.tw//backend/DownLoad/DownLoad/Power/DRAWING/MHU2MA00.pdf CB:http://www.zippy.com.tw//backend/DownLoad/DownLoad/Power/CB/MHU2%20&%20MPSM-V%20CB.pdf FCC:http://www.zippy.com.tw//backend/DownLoad/DownLoad/Power/FCC/MHU2-5400V%20FCC.pdf TUV:http://www.zippy.com.tw//backend/DownLoad/DownLoad/Power/TUV/MHU2-V%20&%20MPSM-V%20TUV.pdf CE (Radiation):http://www.zippy.com.tw//backend/DownLoad/DownLoad/Power/CE/MHU2-5400V%20(Radiation).pdf MTBF(RoHS):http://www.zippy.com.tw//backend/DownLoad/DownLoad/Power/MTBF/MHU2-5400V(RoHS).pdf MTBF(RoHS)(40℃)(NO FAN):http://www.zippy.com.tw//backend/DownLoad/DownLoad/Power/MTBF/MHU2-5400V(RoHS)(40%e2%84%83)(NO%20FAN).pdf MTBF(RoHS)(40℃):http://www.zippy.com.tw//backend/DownLoad/DownLoad/Power/MTBF/MHU2-5400V(RoHS)(40%e2%84%83).pdf MTBF(RoHS)(NO FAN):http://www.zippy.com.tw//backend/DownLoad/DownLoad/Power/MTBF/MHU2-5400V(RoHS)(NO%20FAN).pdf