電源 (Zippy)

    M1Y2-5150V2H(150W)

    製品仕様

    wattage150W
    solutionServer ,Workstation ,Storage System ,IPC
    dimension_mm275x106x41.3
    dimension_inch10.83x4.17x1.63
    input_specVOLTAGE: 90~264VAC FULL RANGEFREQUENCY: 47~63HZINPUT CURRENT:2.5A (RMS) FOR 115 VAC / 1A (RMS) FOR 230 VACINRUSH CURRENT:15A MAX. FOR 115 VAC PER MODULE / 30A MAX. FOR 230 VAC PER MODULEPFC: Up to the target of 95% @115V 90% OF LOAD OR @230V FULL LOAD
    dc_output
    Output Voltage Output Current Min. Output Current Max. Regulation Load Regulation Line Output Ripple & Noise Max.[P-P]
    +5V 0.5 10 ±5% ±1% 50mV
    +12V 2 12 ±5% ±1% 120mV
    +3.3V 0.5 10 ± 5% ±1% 50mV
    -12V 0 0.3 ±10% ± 1% 120mV
    +5VSB 0 2 ±5% ±1% 50mV
    * +5V AND +3.3V Max. POWER: 60W
    * TOTAL POWER: 150W (MAX)


    features* TEMPERATURE RANGE:OPERATING 0℃~50℃, STORAGE -20℃~80℃
    * HOLD UP TIME:WHEN POWER SHUTDOWN DC OUTPUT 12V MUST BE MAINTAIN 15mS IN REGULATION LIMIT AT NORMAL INPUT VOLTAGE
    * EFFICIENCY: SHALL BE MORE THAN 85%, MEASURED AT NOMINAL INPUT VOLTAGE 115V OR 230V AND FULL LOADING
    * LEAKAGE CURRENT: 3.5mA MAX. AT NOMINAL VOLTAGE 240VAC AND 60Hz.
    * REMOTE ON/OFF CONTROL
    * OVER POWER PROTECTION:A MODULE OVER POWER PROTECTION POINT IS 110%~200%; 1+1 MODULE OVER POWER PROTECTION POINT IS 220%~400%.
    * OVER VOLTAGE PROTECTION: +5V→5.7~6.5V, +3.3V→3.7~4.3V, +12V→13.3~15V
    * SHORT CIRCUIT PROTECTION: +5V, +3.3V, +12V
    * OVER CURRENT PROTECTION
    * SAFETY: TO MEET UL, CUL, TUV, CCC
    * WARNING METHOD: AUDIO ALARM(BUZZER SOUND, RESETABLE), FALUT LED, TTL

    * THE POWER-SUPPLY IS FOR CHASSIS-ASSEMBLY ONLY AND IS NOT ALLOWED TO BE OPERATED AS STAND-ALONE COMPONENT. FINAL ASSEMBLY HAS TO COMPLY WITH CORRESPONDING EMC- AND SAFETY-REGULATIONS.
    pdfCB:http://www.zippy.com.tw//backend/DownLoad/DownLoad/Power/CB/M1Y-G%20&%20M1Y2-G%20CB.pdf TUV:http://www.zippy.com.tw//backend/DownLoad/DownLoad/Power/TUV/M1Y-G%20&%20M1Y2-G%20TUV.pdf CCC:http://www.zippy.com.tw//backend/DownLoad/DownLoad/Power/CCC/M1Y2-V%20&%20-G%20&%20-K%20CCC.pdf DRAWING:http://www.zippy.com.tw//backend/DownLoad/DownLoad/Power/DRAWING/M1Y2GMA00.pdf MTBF(RoHS):http://www.zippy.com.tw//backend/DownLoad/DownLoad/Power/MTBF/M1Y2-5150V2H(RoHS)(PMBus%20NP1.2).pdf BSMI:http://www.zippy.com.tw//backend/DownLoad/DownLoad/Power/BSMI/M1Y-G%20&%20M1Y2-G%20BSMI.pdf