電源 (Zippy)

    MRT-5320G0V(320W)

    製品仕様

    wattage320W
    solutionServer ,Workstation ,Storage System ,IPC
    dimension_mm185x150x86
    dimension_inch7.28x5.91x3.39
    input_specVOLTAGE: 90 ~ 264 VAC FULL RANGE FREQUENCY : 47 ~ 63 Hz INPUT CURRENT: 5/3A @ 115 / 230 VAC INRUSH CURRENT: 25/50 AMPS @115/230 VAC (AT 25 DEGREES AMBIENT COLD START FOR EACH POWER UNIT) POWER FACTOR CORRECTION: PFC CAN REACH THE TARGET OF 95% @ 115V, FULL LOAD, FOLLOWING THE STANDARD OF IEC 1000-3-2
    dc_output
    Output Voltage Output Current Min. Output Current Max. Regulation Load Regulation Line Output Ripple & Noise Max.[P-P]
    +5V 1.0 25 ±5% ±1% 50mV
    +12V 1.0 26 ±5% ±1% 120mV
    -12V 0 0.5 ±5% ±1% 150mV
    +3.3V 1.0 20 ±5% ± 1% 50mV
    +5VSB 0.1 3 ±5% ±1% 50mV
    * +5V AND +3.3V MAX. POWER: 150W
    * TOTAL POWER: 320W (MAX)


    features* TEMPERATURE RANGE : OPERATING 0℃ ~ 50℃, STORAGE –20℃ ~ 80℃
    * HOLD UP TIME: 16 ms MINIMUM AT FULL LOAD & 90 VAC INPUT VOLTAGE
    * EFFICIENCY: THE MAXIMUM POWER SUPPLY SYSTEM EFFICIENCY SHALL BE 87.8%, MEASURED AT NOMINAL INPUT VOLTAGE 230V AND FULL LOADING.
    * POWER GOOD SIGNAL: ON DELAY 100 ms TO 500 ms, OFF DELAY 1 ms
    * OUTPUT PROTECTION: OPP / OVP / OCP / SCP
    * FAULTY ALARM METHODS: LED, BUZZER, TTL SIGNAL
    * HOT-SWAPPABLE / HOT-PLUGGABLE REDUNDANCY FUNCTION
    * BALANCE LOAD SHARING DESIGN
    * REMOTE ON/OFF CONTROL
    * LEAKAGE CURRENT: 3.5mA. RMS. MEASUREMENT WILL BE MADE AT 240VAC AND 60HZ
    * ISOLATION: BUILT-IN IN THE POWER MODULE

    * THE POWER-SUPPLY IS FOR CHASSIS-ASSEMBLY ONLY AND IS NOT ALLOWED TO BE OPERATED AS STAND-ALONE COMPONENT. FINAL ASSEMBLY HAS TO COMPLY WITH CORRESPONDING EMC- AND SAFETY-REGULATIONS.
    pdfDRAWING:http://www.zippy.com.tw//backend/DownLoad/DownLoad/Power/DRAWING/MRTGMA00.pdf CE(Radiation):http://www.zippy.com.tw//backend/DownLoad/DownLoad/Power/CE/MRT-5320G0V%20(Radiation).pdf FCC:http://www.zippy.com.tw//backend/DownLoad/DownLoad/Power/FCC/MRT-5320G0V%20FCC.pdf CB:http://www.zippy.com.tw//backend/DownLoad/DownLoad/Power/CB/MRT-G%20&%20MRT-5XXXG0V%20CB.pdf MTBF(ROHS):http://www.zippy.com.tw//backend/DownLoad/DownLoad/Power/MTBF/MRT-5320G0V(RoHS).pdf TUV:http://www.zippy.com.tw//backend/DownLoad/DownLoad/Power/TUV/MRT-G%20TUVpdf.pdf CCC:http://www.zippy.com.tw//backend/DownLoad/DownLoad/Power/CCC/MRT-5320G0V%20CCC.pdf