電源 (Zippy)

    M1P4-6D50V4H(1350W)

    製品仕様

    wattage1350W
    solutionServer ,Workstation ,IPC
    dimension_mm260x359x41.8
    dimension_inch10.24x14.13x1.65
    input_specVOLTAGE: 90V ~ 264VAC (WITH ± 10% TOLERANCE) FREQUENCY: 47Hz ~ 63Hz INPUT CURRENT: 21/10A MAX AT ANY LOW/HIGH INPUT VOLTAGE INRUSH CURRENT: 40/60A @ 115/230VAC (25℃) POWER FACTOR CORRECTION: PFC CAN REACH THE TARGET OF 95% @ 115V, FULL LOAD, FOLLOWING THE STANDARD OF IEC 1000-3-2
    dc_output
    Output Voltage Output Current Min. Output Current Max. Regulation Load Regulation Line Output Ripple & Noise Max.[P-P]
    +5V1 0.5 32 ±5% ±1% 50mV
    +5V2 0.5 32 ±5% ±1% 50mV
    +12V 6 112 ±5% ±1% 50mV
    -12V 0.1 0.5 ±5% ±1% 50mV
    +3.3V 0.5 25 ±5% ±1% 50mV
    +5VSB 0.5 6 ±5% ±1% 50mV
    * +5V1, +5V2 AND +3.3V TOTAL OUTPUT MAX: 350W
    * TOTAL OUTPUT MAX: 1350W


    features* TEMPERATURE RANGE: OPERATING: 0℃ ~ 40℃, STORAGE: -20℃ ~ 80℃
    * HOLD UP TIME: 16 ms MINIMUM AT FULL LOAD & NORMAL INPUT VOLTAGE
    * EFFICIENCY: 80% TYPICAL AT 115VAC FULL LOAD
    * POWER GOOD SIGNAL: ON DELAY 100 ms TO 500 ms, OFF DELAY 1 ms
    * OUTPUT PROTECTION: OPP / OVP / OCP / SCP
    * REMOTE ON/OFF CONTROL
    * FAULTY ALARM METHODS: LED, BUZZER, TTL SIGNAL
    * HOT-SWAPPABLE/HOT PLUGGABLE REDUNDANCY FUNCTION
    * ISOLATION: BUILT-IN THE POWER MODULE
    * SAFETY: TO MEET UL, CUL, TUV, CCC
    * REMOTE SENSING DESIGN

    * THE POWER-SUPPLY IS FOR CHASSIS-ASSEMBLY ONLY AND IS NOT ALLOWED TO BE OPERATED AS STAND-ALONE COMPONENT. FINAL ASSEMBLY HAS TO COMPLY WITH CORRESPONDING EMC- AND SAFETY-REGULATIONS.
    pdfMTBF(RoHS):http://www.zippy.com.tw//backend/DownLoad/DownLoad/Power/MTBF/M1P4-6D50V4H(RoHS).pdf DRAWING:http://www.zippy.com.tw//backend/DownLoad/DownLoad/Power/DRAWING/M1P4VMA00.pdf CE(Radiation):http://www.zippy.com.tw//backend/DownLoad/DownLoad/Power/CE/M1P4-6D50V4H%20(Radiation).pdf FCC:http://www.zippy.com.tw//backend/DownLoad/DownLoad/Power/FCC/M1P4-6D50V4H%20FCC.pdf MTBF(RoHS)(40℃):http://www.zippy.com.tw//backend/DownLoad/DownLoad/Power/MTBF/M1P4-6D50V4H(RoHS)(40%e2%84%83).pdf CB:http://www.zippy.com.tw//backend/DownLoad/DownLoad/Power/CB/M1P-V%20&%20M1P2-V%20&%20M1P4-V%20%20CB.pdf TUV:http://www.zippy.com.tw//backend/DownLoad/DownLoad/Power/TUV/M1P-V%20&%20M1P2-V%20&%20M1P4-V%20TUV.pdf