電源 (Zippy)

    MTW4-5H80V3H(1780W)

    製品仕様

    wattage1780W
    solutionServer ,Workstation ,Storage System ,IPC ,Communication ,Networking
    dimension_mm340x422x43
    dimension_inch13.39x16.61x3.27
    input_specVOLTAGE: 90~264VAC FULL RANGE FREQUENCY: 47~63HZ INPUT CURRENT (PER POWER MODULE):27/12A FOR 115/230VAC INRUSH CURRENT (PER POWER MODULE):40/60A MAX. FOR 115/230VAC (25℃)
    dc_output
    Output Voltage Output Current Min. Output Current Max. Regulation Load Regulation Line Output Ripple & Noise Max.[P-P]
    +5V 1.5 86 ±5% ±1% 50mV
    +12V 6.0 135 ±5% ±1% 120mV
    -12V 0.1 1.6 ±5% ±1% 120mV
    +3.3V 1.5 97 ±5% ±1% 50mV
    +5VSB 0.3 7.0 ±5% ±1% 50mV
    * TOTAL MAX OUTPUT OF +5V AND +3.3V NOT EXCEED 540W.
    * TOTAL OUTPUT MAX: 1780W.


    features* TEMPERATURE RANGE:OPERATING 0℃~45℃, STORAGE -20℃~80℃
    * HOLD UP TIME:16mS IN REGULATOIN LIMIT AT 90VAC INPUT VOLTAGE
    * DIELECTRIC WITHSTAND:INPUT/OUTPUT 1500 VAC FOR 1 MINUTE INPUT TO FRAME GROUND 1500 VAC FOR 1 MINUTE
    * EFFICIENCY:>80% AT 115VAC, 30%~100% MAX LOAD
    * POWER GOOD SIGNAL:ON DELAY 100mS TO 500Ms
    * OVER POWER PROTECTION: 110~160%
    * OVER VOLTAGE PROTECTION:+3.3V→3.9V~4.7V,+5V→5.7V~6.5V ,+12V→12.8 V~13.9V
    * OVER CURRENT PROTECTION: +5V,+12V,+3.3V 110~ 160% AT FULL LOAD
    * SHORT CIRCUIT PROTECTION: +5V, +3.3V, +12V, -12V
    * REMOTE ON / OFF CONTROL
    * BALANCE LOAD SHARING DESIGN
    * HOT-SWAPPABLE/HOT PLUGGABLE REDUNDANCY FUNCTION
    * ISOLATION: BUILT-IN THE POWER MODULE
    * FAULTY ALARM METHODS: LED, BUZZER, TTL SIGNAL
    * COOLING:38*28mm, TWO DC FAN (PER MODULE)
    * EMI NOISE FILTER: FCC CLASS B , CISPR 22 CLASS B
    * MEET IEC-1000-3-2 CLASS D (ACTIVE PFC)
    * SAFETY:TO MEET UL, TUV, CB IEC60950


    *THE POWER-SUPPLY IS FOR CHASSIS-ASSEMBLY ONLY AND IS NOT ALLOWED TO BE OPERATED AS STAND-ALONE COMPONENT. FINAL ASSEMBLY HAS TO COMPLY WITH CORRESPONDING EMC- AND SAFETY-REGULATIONS.
    pdfCB:http://www.zippy.com.tw//backend/DownLoad/DownLoad/Power/CB/MTW-V%20&%20MTW2-V%20&%20MTW4-V%20CB.pdf TUV:http://www.zippy.com.tw//backend/DownLoad/DownLoad/Power/TUV/MTW-V%20&%20MTW2-V%20&%20MTW4-V%20TUV.pdf DRAWING:http://www.zippy.com.tw//backend/DownLoad/DownLoad/Power/DRAWING/MTW4MA00.pdf FCC:http://www.zippy.com.tw//backend/DownLoad/DownLoad/Power/FCC/MTW4-5H80V3H%20FCC.pdf CE:http://www.zippy.com.tw//backend/DownLoad/DownLoad/Power/CE/MTW4-5H80V3H.pdf MTBF(RoHS):http://www.zippy.com.tw//backend/DownLoad/DownLoad/Power/MTBF/MTW4-5H80V3H(RoHS).pdf