サーバーマザーボード

    X11DPU-XLL

    第2世代 Xeon Scalable第1世代Xeon Scalable

    製品仕様

    Product SKUs
    MBD-X11DPU-XLLX11DPU-XLL
    Physical Stats
    Form FactorProprietary Ultra/WIO
    Dimensions17" x 16.8" (43.18cm x 42.67cm)
    Processor/Cache
    CPU2nd Generation Intel® Xeon® Scalable Processors (Cascade Lake-SP), Intel® Xeon® Scalable Processors.
    Dual Socket P (LGA 3647) supported, CPU TDP support Up to 205W TDP, 2 UPI up to 10.4 GT/s
    Cores / CacheUp to 28 cores
    NoteBIOS version 3.0a or above is required to support 2nd Generation Intel Xeon Scalable Processors-SP
    System Memory
    Memory CapacityUp to 4TB 3DS ECC RDIMM, DDR4-2933MHz; Up to 4TB 3DS ECC LRDIMM, DDR4-2933MHz, in 16 DIMM slots
    Memory Type2933/2666/2400/2133MHz ECC DDR4 RDIMM, LRDIMM
    DIMM SizesRDIMM: 64GB
    LRDIMM: 128GB
    3DS LRDIMM: 256GB
    Memory Voltage1.2V
    Error DetectionCorrects single-bit errors
    Detects double-bit errors (using ECC memory)
    On-Board Devices
    ChipsetIntel® C621
    SATAIntel® C621 controller for 14 SATA3 (6 Gbps) ports; RAID 0,1,5,10
    IPMIASPEED AST2500
    Network ControllersNetworking options provided via Ultra Riser
    GraphicsAspeed AST2500 BMC
    Input / Output
    SATA14 SATA3 (6Gbps) ports
    USB3 USB 3.0 ports (2 rear + 1 Type A)
    Video Output1 VGA port
    Serial Port / Header1 COM Port (1 rear)
    TPM1 TPM Header
    Others2 ports SuperDOM
    Expansion Slots
    PCI-E1 PCI-E 3.0 x32 Left Riser Slot,
    1 PCI-E 3.0 x8 Center Right Riser Slot,
    1 PCI-E 3.0 x40 Far Right Riser Slot
    System BIOS
    BIOS TypeAMI UEFI
    Management
    SoftwareIntel® Node Manager, IPMI2.0, KVM with dedicated LAN, SPM, SSM, SUM, SuperDoctor® 5, Watchdog
    Power ConfigurationsACPI Power Management
    Power-on mode for AC power recovery
    PC Health Monitoring
    Voltage+12V, +3.3V, +5V, +5V standby, Monitors CPU voltages
    FAN8x 4-pin fan headers (up to 8 fans), PWM fan speed control
    TemperatureSupport to monitor Supermicro AOC temperatures from IPMI or SD 5, Monitoring for CPU and chassis environment, CPU thermal trip support, Thermal Control for 8 Fan Connectors
    LEDCPU / System Overheat LED, UID/Remote UID, BMC/IPMI Heartbeat LED, Power LED
    Other FeaturesACPI power management, ATX Power connector, Chassis intrusion detection, Chassis intrusion header, Control of power-on for recovery from AC power loss, CPU thermal trip support for processor protection, Hyper-Speed Technology hardware acceleration, Node Manager Support, RoHS, SDDC, UID
    Operating Environment
    Operating Temperature Range10°C - 35°C (50°F - 95°F)
    Non-Operating Temperature Range-40°C - 70°C (-40°F - 158°F)
    Operating Relative Humidity Range8% - 90% (non-condensing)
    Non-Operating Relative Humidity Range5% - 95% (non-condensing)