サーバーマザーボード

    X11DDW-NT

    第2世代 Xeon Scalable第1世代Xeon Scalable

    製品仕様

    Product SKUs
    MBD-X11DDW-NTX11DDW-NT
    Physical Stats
    Form FactorProprietary WIO
    Dimensions12.3" x 13.4" (31.24cm x 34.04cm)
    Processor/Cache
    CPU2nd Generation Intel® Xeon® Scalable Processors (Cascade Lake-SP), Intel® Xeon® Scalable Processors.
    Dual Socket P (LGA 3647) supported, CPU TDP support Up to 205W TDP, 2 UPI up to 10.4 GT/s
    System Memory
    Memory CapacityUp to 3TB 3DS ECC RDIMM, DDR4-2933MHz; Up to 3TB 3DS ECC LRDIMM, DDR4-2933MHz, in 12 DIMM slots;
    Up to 2TB Intel® Optane™ DC Persistent Memory in memory mode (Cascade Lake only).
    Memory Type2933/2666/2400/2133MHz ECC DDR4 RDIMM, LRDIMM
    DIMM SizesRDIMM: 64GB, 128GB
    LRDIMM: 64GB, 128GB
    3DS LRDIMM: 128GB, 256GB
    Memory Voltage1.2V
    Error DetectionCorrects single-bit errors
    Detects double-bit errors (using ECC memory)
    On-Board Devices
    ChipsetIntel® C622
    SATAIntel® C622 controller for 14 SATA3 (6 Gbps) ports; RAID 0,1,5,10
    IPMIASPEED AST2500
    Network ControllersDual LAN with 10Gbase-Tfrom C622
    GraphicsAspeed AST2500 BMC
    Input / Output
    LAN2 RJ45 10GBase-T ports
    USB6 USB 3.0 ports (4 rear + 2 headers)
    Video Output1 VGA port
    TPM1 TPM Header
    Expansion Slots
    PCI-E1 PCI-E 3.0 x32 Left Riser Slot,
    1 PCI-E 3.0 x16 Right Riser Slot,
    1 PCI-E 3.0 x16 for Add-On-Module (AOM)(Both CPUs need to be installed for full access to PCI-E slots and onboard controllers. See manual block diagram and AOC Support for details.)
    M.2M.2 Interface: PCI-E 3.0 x4
    Form Factor: 2242, 2260, 2280, 22110
    Key: M-Key
    System BIOS
    BIOS TypeUEFI 256Mb
    Management
    SoftwareIntel® Node Manager, IPMI2.0, KVM with dedicated LAN, SPM, SSM, SUM, SuperDoctor® 5, Watchdog
    PC Health Monitoring
    Voltage+1.8V, +12V, +3.3V, +5V, +5V standby, Memory Voltages, Monitors CPU voltages
    FAN6x 4-pin fan headers (up to 6 fans), 6 fans with tachometer status monitoring, PWM fan speed control, Status monitoring for speed control
    TemperatureCPU thermal trip support, Monitoring for CPU and chassis environment
    LEDCPU / System Overheat LED, UID/Remote UID, BMC/IPMI Heartbeat LED, Power LED
    Other FeaturesChassis intrusion detection, Control of power-on for recovery from AC power loss, CPU thermal trip support for processor protection, Node Manager Support, RoHS, UID
    Operating Environment
    Operating Temperature Range10°C - 35°C (50°F - 95°F)
    Non-Operating Temperature Range-40°C - 70°C (-40°F - 158°F)
    Operating Relative Humidity Range8% - 90% (non-condensing)
    Non-Operating Relative Humidity Range5% - 95% (non-condensing)