電源 (Zippy)

    DM1Z2-5400V3V(400W)

    製品仕様

    wattage400W
    solutionServer ,Workstation ,Storage System ,PCs ,Communication ,Networking
    dimension_mm265x101x84
    dimension_inch10.43x3.98x3.31
    input_specVOLTAGE: -36 ~ -72 VDC, NORMAL -48VDC INPUT CURRENT:14A(RMS)MAXIMUM AT -36 TO -72VDC INRUSH CURRENT:30A AT -48VDC (AT 25 DEGREES AMBIEND COLD START)
    dc_output
    Output Voltage Output Current Min. Output Current Max. Regulation Load Regulation Line Output Ripple & Noise Max.[P-P]
    +5V 0.5 24 ± 5% ± 1% 50mV
    +12V 1 32 ± 5% ± 1% 120mV
    -12V 0 0.8 ±5% ± 1% 120mV
    +3.3V 0 24 ±5% ± 1% 50mV
    +5VSB 0 3.5 ± 5% ± 1% 50mV


    features* TEMPERATURE RANGE:OPERATING 0℃~50℃,STORAGE -20℃~80℃
    * HOLD UP TIME:5V MUST BE MAINTAIN 1.6 mS MIN IN REGULATOIN LIMIT AT INPUT NORMAL VOLTAGE
    * DIELECTRIC WITHSTAND:INPUT/OUTPUT 1500 VAC FOR 1 minute INPUT TO FRAME GROUND 1500 VAC FOR 1 minute
    * EFFICIENCY:>85% TYPICAL,AT INPUT -48V FULL LOAD
    * POWER GOOD SIGNAL:ON DELAY 100mS TO 500mS,OFF DELAY 1mS
    * OVER POWER PROTECTION:110~160% MAX
    * OVER VOLTAGE PROTECTION:+5V→5.7V~6.5V,+3.3V→4.0V~5.7V ,+12V→14.3V~17.3V
    * OVER CURRENT PROTECTION:+5V,+12V,+3.3V
    * SHORT CIRCUIT: +5V, +3.3V, +12V, -12V
    * EMI : FCC CLASS A , CISPR 22 CLASS A
    * SAFETY:TO MEET UL, TUV, IEC 60950
    * REMOTE ON / OFF CONTROL
    * WARMING METHOD: AUDIO ALARM, TTL, LOW ACTIVE
    * DC INLET IN EACH MODULE


    *THE POWER-SUPPLY IS FOR CHASSIS-ASSEMBLY ONLY AND IS NOT ALLOWED TO BE OPERATED AS STAND-ALONE COMPONENT. FINAL ASSEMBLY HAS TO COMPLY WITH CORRESPONDING EMC- AND SAFETY-REGULATIONS.
    pdfCB:http://www.zippy.com.tw//backend/DownLoad/DownLoad/Power/CB/DM1Z-V%20&%20DM1ZX-V%20CB.pdf TUV:http://www.zippy.com.tw//backend/DownLoad/DownLoad/Power/TUV/DM1Z-V%20&%20DM1ZX-V%20TUV.pdf CCC:http://www.zippy.com.tw//backend/DownLoad/DownLoad/Power/CCC/DM1Z-V%20&%20%20DM1ZX-V%20CCC.pdf MTBF(RoHS)(35℃):http://www.zippy.com.tw//backend/DownLoad/DownLoad/Power/MTBF/DM1Z2-5400V3V(RoHS)(35%e2%84%83).pdf MTBF(RoHS):http://www.zippy.com.tw//backend/DownLoad/DownLoad/Power/MTBF/DM1Z2-5400V3V(RoHS).pdf