wattage | 200W | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
solution | Server ,Workstation ,Storage System ,IPC ,Communication ,Networking | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
dimension_mm | 190x100x40 | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
dimension_inch | 7.48x3.94x1.57 | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
input_spec | ‧VOLTAGE: 90 ~ 264 VAC FULL RANGE. ‧FREQUENCY: 47 ~ 63 Hz. ‧INPUT CURRENT: 2A (RMS) FOR 230 VAC ‧4A (RMS) FOR 115 VAC ‧INRUSH CURRENT: 65A MAX. FOR 115 VAC ‧130A MAX. FOR 230 VAC | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
dc_output |
| ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
features | ‧TEMPERATURE RANGE: OPERATING 0℃ --- 50℃ ‧HOLD UP TIME: 16mS MINIMUM AT FULL LOAD & NOMINAL INPUT VOLTAGE ‧DIELECTRIC WITHSTANDING: INPUT/OUTPUT 1800 VAC FOR 1 MINUTE INPUT TO FRAM GROUND 1800 VAC FOR 1 MINUTE ‧EFFICIENCY: 70% TYPICAL AT 115VAC, FULL LOAD ‧POWER GOOD SIGNAL: ON DELAY 100 ms TO 500 ms, OFF DELAY 1 ms ‧OVER LOAD PROTECTION: 110% ~160% MAX ‧OVER VOLTAGE PROTECTION: +5V→5.6V~6.6V, +3.3V→3.6V~4.2V, +12V→13.2V~14.6V ‧SHORT CIRCUIT PROTECTION: +5V、-5V、+12V、-12V、+3.3V ‧EMI NOISE FILTER: FCC CLASS A, CISPR22 CLASS A ‧SAFETY: MEET UL 60950-2, CSA 60950-2, TUV EN-60950-2 ‧REMOTE ON / OFF CONTROL THE POWER SUPPLY SHALL ACCEPT A LOGIC OPEN COLLECTOR LEVEL WHICH WILL DISABLE/ENABLE ALL THE OUTPUT VOLTAGE (EXCLUDE +5V STAND BY) AS LOGIC LEVEL IS LOW, OUTPUTS VOLTAGE WERE ENABLE AS LOGIC LEVEL IS HIGH, OUTPUTS VOLTAGE WERE DISABLE ‧COOLING: 40 mm DC FANS *THE POWER-SUPPLY IS FOR CHASSIS-ASSEMBLY ONLY AND IS NOT ALLOWED TO BE OPERATED AS STAND-ALONE COMPONENT. FINAL ASSEMBLY HAS TO COMPLY WITH CORRESPONDING EMC- AND SAFETY-REGULATIONS. | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TUV:http://www.zippy.com.tw//backend/DownLoad/DownLoad/Power/TUV/H1U%20&%20P1X%20TUV.pdf CB:http://www.zippy.com.tw//backend/DownLoad/DownLoad/Power/CB/H1U,P1X%20CB.pdf MTBF:http://www.zippy.com.tw//backend/DownLoad/DownLoad/Power/MTBF/P1X-6200P.pdf FCC:http://www.zippy.com.tw//backend/DownLoad/DownLoad/Power/FCC/P1X-6200P%20FCC.pdf DRAWING:http://www.zippy.com.tw//backend/DownLoad/DownLoad/Power/DRAWING/P1X0MA00.pdf MTBF(RoHS):http://www.zippy.com.tw//backend/DownLoad/DownLoad/Power/MTBF/P1X-6200P(RoHS).pdf MTBF(RoHS)(50℃)(NO FAN):http://www.zippy.com.tw//backend/DownLoad/DownLoad/Power/MTBF/P1X-6200P(RoHS)(50%e2%84%83)(NO%20FAN).pdf MTBF(RoHS)(50℃):http://www.zippy.com.tw//backend/DownLoad/DownLoad/Power/MTBF/P1X-6200P(RoHS)(50%e2%84%83).pdf CCC:http://www.zippy.com.tw//backend/DownLoad/DownLoad/Power/CCC/H1U%20%20&%20P1X%20CCC.pdf CE(Radiation):http://www.zippy.com.tw//backend/DownLoad/DownLoad/Power/CE/P1X-6200P%20(+Radiation).pdf |