電源 (Zippy)

    M1W-6500P(500W)

    製品仕様

    wattage500W
    solutionServer ,Workstation ,Storage System ,IPC ,Blade server
    dimension_mm265.3x98.4x40
    dimension_inch10.44x3.87x1.57
    input_specVOLTAGE: 90 ~ 264VAC FREQUENCY: 47 ~ 63Hz INPUT CURRENT: 8.0-4.0A MAX AT ANY LOW/HIGH INPUT VOLTAGE INRUSH CURRENT: 60/100A @115/230VAC(25℃) POWER FACTOR CORRECTION: 95% @ 110V, FULL LOAD
    dc_output
    Output Voltage Output Current Min. Output Current Max. Regulation Load Regulation Line Output Ripple & Noise Max.[P-P]
    5V 3.5 30 ± 5% ± 50mV 70mV
    12V 2.0 32 ± 6% ± 50mV 120mV
    -5V 0.05 0.7 +5%, -10% ± 50mV 120mV
    -12V 0.05 0.7 +5, -10% ± 50mV 120mV
    3.3V 1.0 24 ± 5% ± 50mV 70mV
    +5VSB 0.1 2.0 +5%, -6% ± 50mV 70mV


    features* TEMPERATURE RANGE: OPERATING: 0℃---40℃
    STORAGE: -20℃---80℃
    *HUMIDITY:OPERATING:20%-95%, NON-OPERATING:10%-95%
    *REMARKS:85% IS NORMAL CONDITION AND 95% IS WITH SPECIAL COATING PROCESS
    * HOLD UP TIME: 16 ms MINIMUM AT FULL LOAD & NORMAL INPUT VOLTAGE
    * DIELECRIC WITHSTAND: INPUT/OUTPUT 1500VAC FOR 1 SECOND
    INPUT TO FRAME GROUND 1500 VAC FOR 1 SECOND
    * EFFICIENCY: 65% TYPICAL AT 115VAC FULL LOAD
    * POWER GOOD SIGNAL: ON DELAY 100 ms TO 500ms, OFF DELAY 1 ms
    * OVER POWER PROTECTION: 110~180% * OVER VOLTAGE PROTECTION: +5V→5.7~6.5V, 3.3V→3.9V~4.7V, +12V→13.3V~14.3V
    * OVER CURRENT PROTECTION: 110%~180%
    * SHORT CIRCUIT PROTECTION: +5V, -5V, +12V, -12V, +3.3V
    * EMI NOISE FILTER: FCC CLASS A, CISPR2 CLASS A
    * SAFETY: UL 1950, CSA 22.2 NO/950, TUV IEC 950
    * REMOTE ON /OFF CONTROL
    THE UNIT SHALL ACCEPT A LOGIC OPEN COLLECTOR LEVEL WHICH WILL DISABLE/ENABELE ALL THE OUTPUT VOLTAGE(EXCLUDE +5V STANDBY), AS LOGIC LEVEL IS LOW, OUTPUTS VOLTAGE WERE ENABLE, AS LOGIC LEVEL IS HIGH, OUTPUTS VOLTAGE WERE DISABLE.
    * 3.3V/5V REMOTE SENSING
    * COOLING: ONE 38mm DC FAN

    *THE POWER-SUPPLY IS FOR CHASSIS-ASSEMBLY ONLY AND IS NOT ALLOWED TO BE OPERATED AS STAND-ALONE COMPONENT. FINAL ASSEMBLY HAS TO COMPLY WITH CORRESPONDING EMC- AND SAFETY-REGULATIONS.
    pdfCB:http://www.zippy.com.tw//backend/DownLoad/DownLoad/Power/CB/M1WX%20CB.pdf TUV:http://www.zippy.com.tw//backend/DownLoad/DownLoad/Power/TUV/M1WX%20TUV.pdf MTBF:http://www.zippy.com.tw//backend/DownLoad/DownLoad/Power/MTBF/M1W-6500P.pdf CCC:http://www.zippy.com.tw//backend/DownLoad/DownLoad/Power/CCC/M1WX%20CCC%20AC%20IN%208-4A.pdf MTBF(RoHS):http://www.zippy.com.tw//backend/DownLoad/DownLoad/Power/MTBF/M1W-6500P(RoHS).pdf DRAWING:http://www.zippy.com.tw//backend/DownLoad/DownLoad/Power/DRAWING/M1W0MA00.pdf FCC:http://www.zippy.com.tw//backend/DownLoad/DownLoad/Power/FCC/M1W-6500P%20FCC.pdf MANUAL:http://www.zippy.com.tw//backend/DownLoad/DownLoad/Power/MANUAL/MyWx%20Series.pdf BSMI:http://www.zippy.com.tw//backend/DownLoad/DownLoad/Power/BSMI/M1W,M2W,M1W4%20BSMI.pdf CE(Radiation):http://www.zippy.com.tw//backend/DownLoad/DownLoad/Power/CE/M1W-6500P%20(Radiation).pdf