電源 (Zippy)

    M1U2-5750V4V(750W)

    製品仕様

    wattage750W
    solutionServer ,Workstation ,Storage System
    dimension_mm400x54.4x84.6
    dimension_inch15.75x2.14x3.33
    input_specVOLTAGE: 90~264VAC FULL RANGE FREQUENCY: 47~63HZ INPUT CURRENT:6A(RMS)FOR 230VAC 12A(RMS)FOR 115VAC INRUSH CURRENT:15A MAX. FOR 115 VAC PER MODULE 30A MAX. FOR 230 VAC PER MODULE
    dc_output
    Output Voltage Output Current Min. Output Current Max. Regulation Load Regulation Line Output Ripple & Noise Max.[P-P]
    +5V 0 22 ±5% ±1% 50mV
    +12V 2 62 ±5% ±1% 120mV
    -12V 0 0.5 ±5% ±1% 120mV
    +3.3V 0 22 ±5% ±1% 50mV
    +5VSB 0.1 3 ±5% ±1% 50mV


    features* TEMPERATURE RANGE:OPERATING 0℃~50℃,STORAGE -20℃~80℃
    * HOLD UP TIME:11mS MIN. AT FULL LOAD & 115 VAC INPUT VOLTAGE
    * DIELECTRIC WITHSTAND:INPUT/OUTPUT 1500 VAC FOR 1 MINUTE
    * INPUT TO FRAME GROUND 1500 VAC FOR 1 minute
    * EFFICIENCY:TYPICAL 85% AT 115V, 12V/54A 5VSB/0.4A; TYPICAL 88% AT 230V, 12V/54A 5VSB/0.4A
    * POWER GOOD SIGNAL:ON DELAY 100mS TO 500mS,OFF DELAY 1mS
    * OVER POWER PROTECTION:110~150% MAX
    * OVER VOLTAGE PROTECTION:+3.3V→3.7~4.1V, +5V→5.7~6.5V, +12V→12.8~13.9V
    * SHORT CIRCUIT PROTECTION: +5V, +3.3V, +12V, -12V
    * SAFETY:TO MEET UL, CUL, TUV
    * FAULTY ALARM METHODS: LED, BUZZER, TTL SIGNAL
    * MEET IEC-1000-3-2 CLASS D (ACTIVE PFC)
    * DIMENSION:355(D) * 106(W) * 41.8(H) mm


    *THE POWER-SUPPLY IS FOR CHASSIS-ASSEMBLY ONLY AND IS NOT ALLOWED TO BE OPERATED AS STAND-ALONE COMPONENT. FINAL ASSEMBLY HAS TO COMPLY WITH CORRESPONDING EMC- AND SAFETY-REGULATIONS.
    pdfDRAWING:http://www.zippy.com.tw//backend/DownLoad/DownLoad/Power/DRAWING/M1U2MA03.pdf DRAWING:http://www.zippy.com.tw//backend/DownLoad/DownLoad/Power/DRAWING/M1U2MA11.pdf MTBF(RoHS):http://www.zippy.com.tw//backend/DownLoad/DownLoad/Power/MTBF/M1U2-5750V4V(RoHS).pdf MTBF(RoHS))(35℃):http://www.zippy.com.tw//backend/DownLoad/DownLoad/Power/MTBF/M1U2-5750V4V(RoHS)(35%e2%84%83).pdf MTBF(RoHS)(50℃):http://www.zippy.com.tw//backend/DownLoad/DownLoad/Power/MTBF/M1U2-5750V4V(RoHS)(50%e2%84%83).pdf MTBF(RoHS)(40℃):http://www.zippy.com.tw//backend/DownLoad/DownLoad/Power/MTBF/M1U2-5750V4V(RoHS)(40%e2%84%83).pdf CE(Radiation):http://www.zippy.com.tw//backend/DownLoad/DownLoad/Power/CE/M1U2-5750V4V%20(Radiation).pdf BSMI:http://www.zippy.com.tw//backend/DownLoad/DownLoad/Power/BSMI/M1U-V%20&%20M1V-V%20&%20M1U2-V%20&%20M1V2-V%20BSMI.pdf