電源 (Zippy)

    R2A-6300P(300W)

    製品仕様

    wattage300W
    solutionServer ,Workstation ,Storage System ,IPC
    dimension_mm220x120x85
    dimension_inch8.66x4.72x3.35
    input_specVOLTAGE: 90 ~ 264 VAC FULL RANGE
    dc_output
    Output Voltage Output Current Min. Output Current Max. Regulation Load Regulation Line Output Ripple & Noise Max.[P-P]
    5V 3 32 ± 5% ± 1% 50mV
    12V 2 16 ± 7% ± 1% 120mV
    -5V 0.05 0.5 ±10% ± 1% 150mV
    -12V 0.05 0.8 ±10% ± 1% 150mV
    3.3V 1 20 ± 5% ± 1% 50mV
    +5VSB 0.1 1.5 ± 5% ± 1% 60mV
    REMARKS: *TOTAL CURRENT OF +5V AND + 3.3V NOT EXCEED 35 A *TOTAL +5V AND 3.3V AND 12V POWER NOT EXCEED 285 W

    features*Active PFC (full range), MEET IEC-1000-3-2 CLASS D
    *TEMPERATURE RANGE : OPERATING 0℃ ~ 40℃, STORAGE –20℃ ~ 80℃
    * HUMIDITY:OPERATING:20%-95%, NON-OPERATING:10%-95%
    * REMARKS:85% IS NORMAL CONDITION AND 95% IS WITH SPECIAL COATING PROCESS
    *DUAL EMI NOISE INLET FILTER: FCC CLASS B, CISPR22 CLASS B
    *SAFETY: UL 1950, CSA 22.2 NO/ 950, TUV IEC 950
    *HOT-SWAPPABLE / HOT-PLUGGABLE REDUNDANCY FUNCTION
    *Use 48-pins industrial connectors
    *Cooling: TWO 40 mm DC FANS PER MODULE
    *Dual Inlets
    *Serial ATA optional

    *THE POWER-SUPPLY IS FOR CHASSIS-ASSEMBLY ONLY AND IS NOT ALLOWED TO BE OPERATED AS STAND-ALONE COMPONENT. FINAL ASSEMBLY HAS TO COMPLY WITH CORRESPONDING EMC- AND SAFETY-REGULATIONS.
    pdfDRAWING:http://www.zippy.com.tw//backend/DownLoad/DownLoad/Power/DRAWING/R2A0MA00.pdf CB:http://www.zippy.com.tw//backend/DownLoad/DownLoad/Power/CB/R2A-P.pdf FCC:http://www.zippy.com.tw//backend/DownLoad/DownLoad/Power/FCC/R2A-6300P.pdf TUV:http://www.zippy.com.tw//backend/DownLoad/DownLoad/Power/TUV/R2A-P-R,P%20TUV.PDF MTBF:http://www.zippy.com.tw//backend/DownLoad/DownLoad/Power/MTBF/R2A-6300P.pdf CCC:http://www.zippy.com.tw//backend/DownLoad/DownLoad/Power/CCC/R2A-P%20CCC.pdf MANUAL:http://www.zippy.com.tw//backend/DownLoad/DownLoad/Power/MANUAL/R2A%20Series.pdf MTBF(ROHS):http://www.zippy.com.tw//backend/DownLoad/DownLoad/Power/MTBF/R2A-6300P(RoHS).pdf CE:http://www.zippy.com.tw//backend/DownLoad/DownLoad/Power/CE/R2A-6300P%20(+Radiation).pdf