電源 (Zippy)

    DM1S-3400V(400W)

    製品仕様

    wattage400W
    solutionIPC ,Communication ,Networking
    dimension_mm300x50.5x40
    dimension_inch11.81x1.99x1.57
    input_specVOLTAGE: -36 ~ -72VDC FREQUENCY: -48VDC STEADY-STATE CURRENT: -36 ~ -72VDC / 15~7 AMP (11 AMP AT -48VDC); (AT 25 DEGREES AMBIENT COLD START)
    dc_output
    Output Voltage Output Current Min. Output Current Max. Regulation Load Regulation Line Output Ripple & Noise Max.[P-P]
    -12V 0 0.8 ±10% ±1% 120mV
    +12V 2.0 33 ±5% ±1% 120mV
    +5VSB 0.1 3.5 ±5% ±1% 120mV


    features* TEMPERATURE RANGE:OPERATING 0℃~40℃, STORAGE -20℃~80℃; OPERATING TEMPERATURE FROM 0℃ SHOULD START FROM DC -48V
    * HOLD UP TIME:WHEN POWER SHUTDOWN DC OUTPUT 12V MUST BE MAINTAIN 1.6mS IN REGULATION LIMIT AT NORMAL INPUT VOLTAGE
    * DIELECTRIC WITHSTAND:INPUT/OUTPUT 1800 VAC FOR 1 SECOND INPUT TO FRAME GROUND 1800 VAC FOR 1 SECOND
    * EFFICIENCY:>80% AT -48V,FULL LOAD
    * HUMIDITY: OPERATING HUMIDITY: 20%~80%; NON-OPERATING HUMIDITY: 10%~90%
    * POWER GOOD SIGNAL:ON DELAY 100mS TO 500mS
    * OVER POWER PROTECTION:110~170% MAX
    * OVER VOLTAGE PROTECTION: +12V→13.2V~15.6V
    * SHORT CIRCUIT PROTECTION: +12V, -12V; AUTO-RECOVERED: +5VSB
    * EMI NOISE FILTER : CISPR22 CLASS A
    * SAFETY : TO MEET UL60950, TUV EN-60950, CB IEC 60950
    * REMOTE ON/OFF CONTROL
    THE POWER SUPPLY SHALL ACCEPT A LOGIC OPEN COLLECTOR LEVEL WHICH WILL DISABLE/ENABLE ALL THE OUTPUT VOLTAGE (EXCLUDE +5V STAND BY).
    AS LOGIC LEVEL IS LOW,OUTPUTS VOLTAGE WERE ENABLE, AS LOGIC LEVEL IS HIGH,OUTPUTS VOLTAGE WERE DISABLE.


    *THE POWER-SUPPLY IS FOR CHASSIS-ASSEMBLY ONLY AND IS NOT ALLOWED TO BE OPERATED AS STAND-ALONE COMPONENT. FINAL ASSEMBLY HAS TO COMPLY WITH CORRESPONDING EMC- AND SAFETY-REGULATIONS.
    pdfDRAWING:http://www.zippy.com.tw//backend/DownLoad/DownLoad/Power/DRAWING/DM1SMA00.pdf CB:http://www.zippy.com.tw//backend/DownLoad/DownLoad/Power/CB/DM1S-V%20&%20%20DM1S2-V%20CB.pdf TUV:http://www.zippy.com.tw//backend/DownLoad/DownLoad/Power/TUV/DM1S-V%20&%20%20DM1S2-V%20TUV.pdf MTBF(RoHS):http://www.zippy.com.tw//backend/DownLoad/DownLoad/Power/MTBF/DM1S-3400V(RoHS).pdf DRAWING:http://www.zippy.com.tw//backend/DownLoad/DownLoad/Power/DRAWING/DM1SMA01.pdf CCC:http://www.zippy.com.tw//backend/DownLoad/DownLoad/Power/CCC/DM1S-V%20&%20DM1S2-V%20CCC.pdf